메뉴 건너뛰기




Volumn 120, Issue 1-4, 2006, Pages 136-139

Tissue-equivalent TL sheet dosimetry system for X- and gamma-ray dose mapping

Author keywords

[No Author keywords available]

Indexed keywords

COBALT 60;

EID: 33749865783     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/nci571     Document Type: Article
Times cited : (13)

References (11)
  • 2
    • 0025005036 scopus 로고
    • Design of a positionally sensitive laser-heated thermoluminescent detector system
    • Kearfott, K. J. and Grupen-Shemansky, M. E. Design of a positionally sensitive laser-heated thermoluminescent detector system. Health Phys. 59, 421-431 (1990).
    • (1990) Health Phys. , vol.59 , pp. 421-431
    • Kearfott, K.J.1    Grupen-Shemansky, M.E.2
  • 3
    • 0027166282 scopus 로고
    • Laser TLD 2-dimensional dose mapping
    • Jones, S.C. Laser TLD 2-dimensional dose mapping. Radiat. Prot. Dosim. 47, 457-160 (1993).
    • (1993) Radiat. Prot. Dosim. , vol.47 , pp. 160-457
    • Jones, S.C.1
  • 4
    • 0022388499 scopus 로고
    • Spatial distribution readout system of thermoluminescence sheets
    • Imaeda, K. et al. Spatial distribution readout system of thermoluminescence sheets. Nucl. Instrum. Methods A 241, 567-571 (1985).
    • (1985) Nucl. Instrum. Methods A , vol.241 , pp. 567-571
    • Imaeda, K.1
  • 5
    • 0026681037 scopus 로고
    • In vivo measurement of spatial dose distribution with thermoluminescent sheet around high dose-rate intracavitary source: Application to rectal cancer
    • Iwata, K. et al. In vivo measurement of spatial dose distribution with thermoluminescent sheet around high dose-rate intracavitary source: application to rectal cancer. Int. J. Radiat. Oncology Biol. Phys. 22, 1109-1115 (1992).
    • (1992) Int. J. Radiat. Oncology Biol. Phys. , vol.22 , pp. 1109-1115
    • Iwata, K.1
  • 6
    • 0003304896 scopus 로고
    • Development of a new highly sensitive LiF thermoluminescence dosimeter and its applications
    • Nakajima, T., Murayama, Y., Matsuzawa, T. and Koyano, A. Development of a new highly sensitive LiF thermoluminescence dosimeter and its applications. Nucl. Instrum. Meth. 157, 155-162 (1978).
    • (1978) Nucl. Instrum. Meth. , vol.157 , pp. 155-162
    • Nakajima, T.1    Murayama, Y.2    Matsuzawa, T.3    Koyano, A.4
  • 8
    • 0027257649 scopus 로고
    • Microdosimetric interpretation of the anomalous photon energy response of ultra-sensitive LiF:Mg,Cu,P TL dosemeters
    • Olko, P., Bilski, P., Ryba, E. and Niewiadomski, T. Microdosimetric interpretation of the anomalous photon energy response of ultra-sensitive LiF:MG,Cu,P TL dosemeters. Radiat. Prot. Dosim. 47, 31-35 (1993).
    • (1993) Radiat. Prot. Dosim. , vol.47 , pp. 31-35
    • Olko, P.1    Bilski, P.2    Ryba, E.3    Niewiadomski, T.4
  • 10
    • 0034745486 scopus 로고    scopus 로고
    • Dose measurements in inhomogeneous bone/tissue and lung/tissue phantoms for angiography using synchrotron radiation
    • Nariyama, N., Namito, Y., Ban, S. and Hirayama, H. Dose measurements in inhomogeneous bone/tissue and lung/tissue phantoms for angiography using synchrotron radiation. Phys. Med. Biol. 46, 717-728 (2001).
    • (2001) Phys. Med. Biol. , vol.46 , pp. 717-728
    • Nariyama, N.1    Namito, Y.2    Ban, S.3    Hirayama, H.4
  • 11
    • 33749862733 scopus 로고    scopus 로고
    • Energy response of a two-dimensional sheet-type LiF:Mg,Cu,P TL dosimeter to photons
    • Konnai, A., Nariyama, N., Ohnishi, S., Odano, N., Ozasa, N. and Ishikawa, Y. Energy response of a two-dimensional sheet-type LiF:MG,Cu,P TL dosimeter to photons. Radiat. Prot. Dosim. 120(1-4), 125-128 (2006).
    • (2006) Radiat. Prot. Dosim. , vol.120 , Issue.1-4 , pp. 125-128
    • Konnai, A.1    Nariyama, N.2    Ohnishi, S.3    Odano, N.4    Ozasa, N.5    Ishikawa, Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.