메뉴 건너뛰기




Volumn 41, Issue 11, 2006, Pages 831-839

Operator-dependent reproducibility of size measurements of small phantoms and lung nodules examined with low-dose thin-section computed tomography

Author keywords

Computer diagnostic aids; Low dose CT; Lung nodules; Phantoms; Reproducibility

Indexed keywords

ARTICLE; CANCER SCREENING; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC TEST; DIAGNOSTIC VALUE; HUMAN; LOW DOSE THIN SECTION COMPUTED TOMOGRAPHY; LUNG CANCER; LUNG NODULE; MEASUREMENT; PHANTOM; PRIORITY JOURNAL; RADIOLOGIST; REPRODUCIBILITY;

EID: 33749859871     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.rli.0000242837.11436.6e     Document Type: Article
Times cited : (12)

References (32)
  • 1
    • 0034538087 scopus 로고    scopus 로고
    • Small pulmonary nodules: Volumetrically determined growth rates based on CT evaluation
    • Yankelevitz DF, Reeves AP, Kostis WJ, et al. Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation. Radiology. 2000;217:251-256.
    • (2000) Radiology , vol.217 , pp. 251-256
    • Yankelevitz, D.F.1    Reeves, A.P.2    Kostis, W.J.3
  • 2
    • 2142700841 scopus 로고    scopus 로고
    • Pulmonary nodules: Preliminary experience with three-dimensional evaluation
    • Revel MP, Lefort C, Bissery A, et al. Pulmonary nodules: preliminary experience with three-dimensional evaluation. Radiology. 2004;231:459-466.
    • (2004) Radiology , vol.231 , pp. 459-466
    • Revel, M.P.1    Lefort, C.2    Bissery, A.3
  • 3
    • 0042931348 scopus 로고    scopus 로고
    • Small pulmonary nodules: Volume measurement at chest CT - Phantom study
    • Ko JP, Rusinek H, Jacobs EL, et al. Small pulmonary nodules: volume measurement at chest CT - phantom study. Radiology. 2003;228:864-870.
    • (2003) Radiology , vol.228 , pp. 864-870
    • Ko, J.P.1    Rusinek, H.2    Jacobs, E.L.3
  • 4
    • 0842345498 scopus 로고    scopus 로고
    • Volumetric measurements of pulmonary nodules at multi-row detector CT: In vivo reproducibility
    • Wormanns D, Kohl G, Klotz E, et al. Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility. Eur Radiol. 2004;14:86-92.
    • (2004) Eur Radiol , vol.14 , pp. 86-92
    • Wormanns, D.1    Kohl, G.2    Klotz, E.3
  • 5
    • 33646913058 scopus 로고    scopus 로고
    • Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements
    • Goodman LR, Gulsun M, Washington L, et al. Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements. AJR Am J Roentgenol. 2006;186:989-994.
    • (2006) AJR Am J Roentgenol , vol.186 , pp. 989-994
    • Goodman, L.R.1    Gulsun, M.2    Washington, L.3
  • 6
    • 33644890197 scopus 로고    scopus 로고
    • Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria
    • Marten K, Auer F, Schmidt S, et al. Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria. Eur Radiol. 2006;16:781-790.
    • (2006) Eur Radiol , vol.16 , pp. 781-790
    • Marten, K.1    Auer, F.2    Schmidt, S.3
  • 7
    • 33645075495 scopus 로고    scopus 로고
    • Reproducibility of computer-aided volumetry of artificial small pulmonary nodules in ex vivo porcine lungs
    • Bolte H, Riedel C, Jahnke T, et al. Reproducibility of computer-aided volumetry of artificial small pulmonary nodules in ex vivo porcine lungs. Invest Radiol. 2006;41:28-35.
    • (2006) Invest Radiol , vol.41 , pp. 28-35
    • Bolte, H.1    Riedel, C.2    Jahnke, T.3
  • 8
    • 27144449606 scopus 로고    scopus 로고
    • Guidelines for management of small pulmonary nodules detected on CT scans: A statement from the Fleischner Society
    • MacMahon H, Austin JH, Gamsu G, et al. Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleischner Society. Radiology. 2005;237:395-400.
    • (2005) Radiology , vol.237 , pp. 395-400
    • MacMahon, H.1    Austin, J.H.2    Gamsu, G.3
  • 9
    • 9344257538 scopus 로고    scopus 로고
    • Managing the small pulmonary nodule discovered by CT
    • Libby DM, Smith JP, Altorki NK, et al. Managing the small pulmonary nodule discovered by CT. Chest. 2004;125:1522-1529.
    • (2004) Chest , vol.125 , pp. 1522-1529
    • Libby, D.M.1    Smith, J.P.2    Altorki, N.K.3
  • 10
    • 0033542870 scopus 로고    scopus 로고
    • Early Lung Cancer Action Project: Overall design and findings from baseline screening
    • Henschke CI, McCauley DI, Yankelevitz D, et al. Early Lung Cancer Action Project: overall design and findings from baseline screening. Lancet. 1999;354:99-105.
    • (1999) Lancet , vol.354 , pp. 99-105
    • Henschke, C.I.1    McCauley, D.I.2    Yankelevitz, D.3
  • 12
    • 16244392718 scopus 로고    scopus 로고
    • Screening of lung cancer with low dose spiral CT: Results of a three year pilot study and design of the randomised controlled trial "Italung- CT"
    • Picozzi G, Paci E, Lopes Pegna A, et al. Screening of lung cancer with low dose spiral CT: results of a three year pilot study and design of the randomised controlled trial "Italung-CT." Radiol Med. 2005;109:17-26.
    • (2005) Radiol Med , vol.109 , pp. 17-26
    • Picozzi, G.1    Paci, E.2    Lopes Pegna, A.3
  • 13
    • 0141954913 scopus 로고    scopus 로고
    • Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images
    • Kostis WJ, Reeves AP, Yankelevitz DF, et al. Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images. IEEE Trans Medical Imaging. 2003;22:1259-1274.
    • (2003) IEEE Trans Medical Imaging , vol.22 , pp. 1259-1274
    • Kostis, W.J.1    Reeves, A.P.2    Yankelevitz, D.F.3
  • 15
    • 0037202550 scopus 로고    scopus 로고
    • Assessing intrarater, interrater and test-retest reliability of continuous measurements
    • Rousson V, Gasser T, Seifert B. Assessing intrarater, interrater and test-retest reliability of continuous measurements. Stat Med. 2002;21:3431-3446.
    • (2002) Stat Med , vol.21 , pp. 3431-3446
    • Rousson, V.1    Gasser, T.2    Seifert, B.3
  • 16
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 17
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8:135-160.
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 18
    • 85047319897 scopus 로고    scopus 로고
    • Reproducibility, repeatability, correlation and measurement error
    • discussion, 194-195
    • Halligan S. Reproducibility, repeatability, correlation and measurement error. Br J Radiol. 2002;75:193-194; discussion, 194-195.
    • (2002) Br J Radiol , vol.75 , pp. 193-194
    • Halligan, S.1
  • 19
    • 0003486931 scopus 로고
    • World Health Organization. Geneva, Switzerland: World Health Organization
    • World Health Organization. WHO Handbook for Reporting Results of Cancer Treatment. Geneva, Switzerland: World Health Organization; 1979.
    • (1979) WHO Handbook for Reporting Results of Cancer Treatment
  • 20
    • 0034594628 scopus 로고    scopus 로고
    • New guidelines to evaluate the response to treatment in solid tumors
    • European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada
    • Therasse P, Arbuck SG, Eisenhauer EA, et al. New guidelines to evaluate the response to treatment in solid tumors. European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada. J Natl Cancer Inst. 2000;92:205-216.
    • (2000) J Natl Cancer Inst , vol.92 , pp. 205-216
    • Therasse, P.1    Arbuck, S.G.2    Eisenhauer, E.A.3
  • 21
    • 0038417130 scopus 로고    scopus 로고
    • Radiological measurement of breast cancer metastases to lung and liver: Comparison between WHO (bidimensional) and RECIST (unidimensional) guidelines
    • Prasad SR, Saini S, Sumner JE, et al. Radiological measurement of breast cancer metastases to lung and liver: comparison between WHO (bidimensional) and RECIST (unidimensional) guidelines. J Computer Assist Tomogr. 2003;27:380-384.
    • (2003) J Computer Assist Tomogr , vol.27 , pp. 380-384
    • Prasad, S.R.1    Saini, S.2    Sumner, J.E.3
  • 22
    • 2142697951 scopus 로고    scopus 로고
    • Are two-dimensional CT measurements of small noncalcified pulmonary nodules reliable?
    • Revel MP, Bissery A, Bienvenu M, et al. Are two-dimensional CT measurements of small noncalcified pulmonary nodules reliable? Radiology. 2004;231:453-458.
    • (2004) Radiology , vol.231 , pp. 453-458
    • Revel, M.P.1    Bissery, A.2    Bienvenu, M.3
  • 23
    • 0038352143 scopus 로고    scopus 로고
    • Interobserver and intraobserver variability in measurements of non-small-cell carcinoma lung lesions: Implications for assessment of tumor response
    • Erasmus JJ, Gladish GW, Broemeling L, et al. Interobserver and intraobserver variability in measurements of non-small-cell carcinoma lung lesions: implications for assessment of tumor response. J Clin Oncol. 2003;21:2574-2582.
    • (2003) J Clin Oncol , vol.21 , pp. 2574-2582
    • Erasmus, J.J.1    Gladish, G.W.2    Broemeling, L.3
  • 24
    • 33645697952 scopus 로고    scopus 로고
    • Morphological segmentation and partial volume analysis for volumetry of solid pulmonary lesions in thoracic CT scans
    • Kuhnigk JM, Dicken V, Bornemann L, et al. Morphological segmentation and partial volume analysis for volumetry of solid pulmonary lesions in thoracic CT scans. IEEE Trans Med Imaging. 2006;25:417-434.
    • (2006) IEEE Trans Med Imaging , vol.25 , pp. 417-434
    • Kuhnigk, J.M.1    Dicken, V.2    Bornemann, L.3
  • 25
    • 2142812310 scopus 로고    scopus 로고
    • Small pulmonary nodules: Reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT
    • Kostis WJ, Yankelevitz DF, Reeves AP, et al. Small pulmonary nodules: reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT. Radiology. 2004;231:446-452.
    • (2004) Radiology , vol.231 , pp. 446-452
    • Kostis, W.J.1    Yankelevitz, D.F.2    Reeves, A.P.3
  • 26
    • 33645115231 scopus 로고    scopus 로고
    • Effect of blood vessels on measurement of nodule volume in a chest phantom
    • Ko JP, Marcus R, Bomsztyk E, et al. Effect of blood vessels on measurement of nodule volume in a chest phantom. Radiology. 2006;239:79-85.
    • (2006) Radiology , vol.239 , pp. 79-85
    • Ko, J.P.1    Marcus, R.2    Bomsztyk, E.3
  • 27
    • 16544371693 scopus 로고    scopus 로고
    • Volumetric assessment of pulmonary nodules with ECG-gated MDCT
    • Boll DT, Gilkeson RC, Fleiter TR, et al. Volumetric assessment of pulmonary nodules with ECG-gated MDCT. AJR Am J Roentgenol. 2004;183:1217-1223.
    • (2004) AJR Am J Roentgenol , vol.183 , pp. 1217-1223
    • Boll, D.T.1    Gilkeson, R.C.2    Fleiter, T.R.3
  • 28
    • 0041464868 scopus 로고    scopus 로고
    • Early lung-cancer detection with spiral CT and positron emission tomography in heavy smokers: 2 Years results
    • Pastorino U, Bellomi M, Landoni C, et al. Early lung-cancer detection with spiral CT and positron emission tomography in heavy smokers: 2 years results. Lancet. 2003;362:593-597.
    • (2003) Lancet , vol.362 , pp. 593-597
    • Pastorino, U.1    Bellomi, M.2    Landoni, C.3
  • 29
    • 1642296713 scopus 로고    scopus 로고
    • CT screening for lung cancer: Suspiciousness of nodules according to size on baseline scans
    • Henschke CI, Yankelevitz DF, Naidich DP, et al. CT screening for lung cancer: suspiciousness of nodules according to size on baseline scans. Radiology. 2004;231:164-168.
    • (2004) Radiology , vol.231 , pp. 164-168
    • Henschke, C.I.1    Yankelevitz, D.F.2    Naidich, D.P.3
  • 30
    • 33749839229 scopus 로고    scopus 로고
    • Baseline findings of a randomized Ducth-Belgian trial on lung cancer screening by low-dose CT (NELSON study)
    • Xu D, Vliegenthart R, Wang Y, et al. Baseline findings of a randomized Ducth-Belgian trial on lung cancer screening by low-dose CT (NELSON study). Eur Radiol. 2006;(Suppl 1):144.
    • (2006) Eur Radiol , Issue.SUPPL. 1 , pp. 144
    • Xu, D.1    Vliegenthart, R.2    Wang, Y.3
  • 31
    • 0036109223 scopus 로고    scopus 로고
    • CT screening for lung cancer: Frequency and significance of part-solid and nonsolid nodules
    • Henschke CI, Yankelevitz DF, Mirtcheva R, et al. CT screening for lung cancer: frequency and significance of part-solid and nonsolid nodules. AJR Am J Roentgenol. 2002;178:1053-1057.
    • (2002) AJR Am J Roentgenol. , vol.178 , pp. 1053-1057
    • Henschke, C.I.1    Yankelevitz, D.F.2    Mirtcheva, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.