메뉴 건너뛰기




Volumn 120, Issue 1-4, 2006, Pages 414-420

The intercomparison of cosmic rays with heavy ion beams at NIRS (ICCHIBAN) project

Author keywords

[No Author keywords available]

Indexed keywords

HELIUM; IRON; SILICON;

EID: 33749847535     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/nci536     Document Type: Article
Times cited : (24)

References (8)
  • 1
    • 27744454550 scopus 로고    scopus 로고
    • Results from the first two InterComparison of dosimetric instruments for Cosmic radiation with Heavy Ions Beams at NIRS (ICCHIBAN-1&2) experiments
    • Uchihori, Y. and Benton E. R., Eds. National Insititute for Radiological Sciences HIMAC-078, Chiba, Japan
    • Uchihori, Y. and Benton E. R., Eds. (2004) Results from the first two InterComparison of dosimetric instruments for Cosmic radiation with Heavy Ions Beams at NIRS (ICCHIBAN-1&2) experiments. National Insititute for Radiological Sciences HIMAC-078, Chiba, Japan.
    • (2004)
  • 2
    • 0033011695 scopus 로고    scopus 로고
    • Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy
    • Kanai, T. et al. Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy. Int. J. Radiat. Oncol. Biol. Phy. 44(1), 201-210 (1999).
    • (1999) Int. J. Radiat. Oncol. Biol. Phy. , vol.44 , Issue.1 , pp. 201-210
    • Kanai, T.1
  • 3
    • 33749818451 scopus 로고
    • Heavy particle range-energy relations for dielectric nuclear track detectors
    • Benton, E. V. and Henke, R. P. Heavy particle range-energy relations for dielectric nuclear track detectors. Nucl. Instr. Meth. 67(2), 483-489 (1969).
    • (1969) Nucl. Instr. Meth. , vol.67 , Issue.2 , pp. 483-489
    • Benton, E.V.1    Henke, R.P.2
  • 4
    • 0038002028 scopus 로고    scopus 로고
    • Modeling the response of thermoluminesence detectors exposed to low- and high-LET radiation fields
    • Olko, P., Bilski, P., Budzanowski, M., Waligorski, M. P. R. and Reitz, G. Modeling the response of thermoluminesence detectors exposed to low- and high-LET radiation fields. J. Radiat. Res., 43, S59-S62 (2002).
    • (2002) J. Radiat. Res. , vol.43
    • Olko, P.1    Bilski, P.2    Budzanowski, M.3    Waligorski, M.P.R.4    Reitz, G.5
  • 6
    • 4344622647 scopus 로고    scopus 로고
    • LiF:Mg,Ti (MTT) TL detectors optimised for high-LET radiation dosimetry
    • Bilski, P., Budzanowski, M., Olko, P. and Mandowska, E. LiF:MG,Ti (MTT) TL detectors optimised for high-LET radiation dosimetry. Radiat. Meas. 38(4-6), 427-430 (2004).
    • (2004) Radiat. Meas. , vol.38 , Issue.4-6 , pp. 427-430
    • Bilski, P.1    Budzanowski, M.2    Olko, P.3    Mandowska, E.4
  • 7
    • 0032810136 scopus 로고    scopus 로고
    • The LET dependence of LiF:Mg,Ti dosemeters and its application for LET measurements in mixed radiation fields
    • Schöner, W., Vana, N. and Fugger, M. The LET dependence of LiF:MG,Ti dosemeters and its application for LET measurements in mixed radiation fields. Radiat. Prot. Dosim. 85(1-4), 263 (1999).
    • (1999) Radiat. Prot. Dosim. , vol.85 , Issue.1-4 , pp. 263
    • Schöner, W.1    Vana, N.2    Fugger, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.