메뉴 건너뛰기




Volumn 120, Issue 1-4, 2006, Pages 171-175

EPR/lalanine dosimetry in LDR brachytherapy - A feasibility study

Author keywords

[No Author keywords available]

Indexed keywords

ALANINE; CESIUM 137; IRIDIUM 192;

EID: 33749838690     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/nci528     Document Type: Article
Times cited : (27)

References (10)
  • 1
    • 0024881924 scopus 로고
    • ESR/alanine dosimetry of high-energy electrons in radiotherapy
    • Chu, S., Wieser, A., Feist, H. and Regulla, D. F. ESR/alanine dosimetry of high-energy electrons in radiotherapy. Appl. Radiat. Isot. 40(10-12), 993-996 (1989).
    • (1989) Appl. Radiat. Isot. , vol.40 , Issue.10-12 , pp. 993-996
    • Chu, S.1    Wieser, A.2    Feist, H.3    Regulla, D.F.4
  • 2
    • 0027607989 scopus 로고
    • The application of EPR dosimetry for radiotherapy and radiation protection
    • Kudyński, R., Kudyńska, J. and Buckmaster, H. E. The application of EPR dosimetry for radiotherapy and radiation protection. Appl. Radiat. Isot. 44(6), 903-906 (1993).
    • (1993) Appl. Radiat. Isot. , vol.44 , Issue.6 , pp. 903-906
    • Kudyński, R.1    Kudyńska, J.2    Buckmaster, H.E.3
  • 6
    • 0030293066 scopus 로고    scopus 로고
    • One year of experience with alanine dosimetry in radiotherapy
    • Schaeken, B. and Scalliet, P. One year of experience with alanine dosimetry in radiotherapy. Appl. Radiat. Isot. 47, 1177-1182 (1996).
    • (1996) Appl. Radiat. Isot. , vol.47 , pp. 1177-1182
    • Schaeken, B.1    Scalliet, P.2
  • 7
    • 0030294823 scopus 로고    scopus 로고
    • Alanine-ESR in vivo dosimetry: A feasibility study and possible applications
    • Kuntz, F., Pabst, J. Y., Delpech, J. P., Wagner, J. P. and Marchioni, E. Alanine-ESR in vivo dosimetry: A feasibility study and possible applications. Appl. Radiat. Isot. 47, 1183-1188 (1996).
    • (1996) Appl. Radiat. Isot. , vol.47 , pp. 1183-1188
    • Kuntz, F.1    Pabst, J.Y.2    Delpech, J.P.3    Wagner, J.P.4    Marchioni, E.5
  • 8
    • 12544250032 scopus 로고    scopus 로고
    • In vivo dosimetry using electron paramagnetic resonance in L-alanine in gynecological low dose rate brachytherapy
    • Schultka, K., Ciesielski, B., Serkies, K., Wysocka, B., Sawicki, T., Tarnawska, Z. and Jassem, J. In vivo dosimetry using electron paramagnetic resonance in L-alanine in gynecological low dose rate brachytherapy. Nowotwory J. Oncol. 6, 26-29 (2004).
    • (2004) Nowotwory J. Oncol. , vol.6 , pp. 26-29
    • Schultka, K.1    Ciesielski, B.2    Serkies, K.3    Wysocka, B.4    Sawicki, T.5    Tarnawska, Z.6    Jassem, J.7
  • 9
    • 0035915739 scopus 로고    scopus 로고
    • Rectal doses in intracavitary brachytherapy of gynecological malignancies: Comparison of two dosimetric methods
    • Serkies, K., Badzio, A., Jereczek-Fossa, B., Tarnawska, Z., Nowak, R., Szewczyk, P. and Jassem, J. Rectal doses in intracavitary brachytherapy of gynecological malignancies: Comparison of two dosimetric methods. Radiother. Oncol. 58, 37-41 (2001).
    • (2001) Radiother. Oncol. , vol.58 , pp. 37-41
    • Serkies, K.1    Badzio, A.2    Jereczek-Fossa, B.3    Tarnawska, Z.4    Nowak, R.5    Szewczyk, P.6    Jassem, J.7
  • 10
    • 0033991649 scopus 로고    scopus 로고
    • Advencements in accuracy of the alanine dosimetry system: Part 2. The influence of irradiation temperature
    • Nagy, V., Puhl, J. P. and Desrosiers, M. F. Advencements in accuracy of the alanine dosimetry system: Part 2. The influence of irradiation temperature. Radiat. Phys. Chem. 57, 1-9 (2000).
    • (2000) Radiat. Phys. Chem. , vol.57 , pp. 1-9
    • Nagy, V.1    Puhl, J.P.2    Desrosiers, M.F.3