Volumn 19, Issue 6, 2006, Pages 509-515

A posteriori hazard analysis and feedback information of an accidental event in the grains storage of an agrochemical product

Author keywords

Hazard analysis; Information feedback; Safety; Silo; Storage; Thermal runaway

Indexed keywords

HAZARD ANALYSIS; INFORMATION FEEDBACK; THERMAL RUNAWAY;

EID: 33749819989     PISSN: 09504230     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jlp.2005.12.006     Document Type: Article
Times cited : (3)

References (16)
  • 1
    • 33749827225 scopus 로고    scopus 로고
    • Baklouti, M. (1997). Détermination de la conductivité thermique effective de milieux poreux granulaires par la méthode du fil chaud en régime transitoire: Modélisation et expériences-Application à la sûreté d'un stockage. INPL Ph.D. thesis Nancy, 17 janvier 1997.
  • 2
    • 21744440256 scopus 로고    scopus 로고
    • Effective thermal conductivity measurements by the transient hot-wire method. Investigation of the interpretation procedure of experimental data
    • Baklouti M., and Laurent A. Effective thermal conductivity measurements by the transient hot-wire method. Investigation of the interpretation procedure of experimental data. High Temperatures-High Pressures 29 (1997) 295-307
    • (1997) High Temperatures-High Pressures , vol.29 , pp. 295-307
    • Baklouti, M.1    Laurent, A.2
  • 3
    • 0036643975 scopus 로고    scopus 로고
    • Autocatalytic decomposition reactions, hazards and detection
    • Bou-Diab L., and Fierz H. Autocatalytic decomposition reactions, hazards and detection. Journal of Hazardous Materials 93 (2002) 137-146
    • (2002) Journal of Hazardous Materials , vol.93 , pp. 137-146
    • Bou-Diab, L.1    Fierz, H.2
  • 4
    • 0041186070 scopus 로고
    • CHETAH program in chemical hazard evaluation
    • Frurip D.J. CHETAH program in chemical hazard evaluation. Plant Operations Progress 11 4 (1992) 224-228
    • (1992) Plant Operations Progress , vol.11 , Issue.4 , pp. 224-228
    • Frurip, D.J.1
  • 5
    • 12344336430 scopus 로고    scopus 로고
    • The role of ASTM E27 methods in hazard assessment. Part I. Thermal stability, compatibility and energy release estimation methods
    • Frurip D., Britton L., Fenlon W., Going J., Harrison B.K., Niemeier J., et al. The role of ASTM E27 methods in hazard assessment. Part I. Thermal stability, compatibility and energy release estimation methods. Process Safety Progress 23 4 (2004) 266-278
    • (2004) Process Safety Progress , vol.23 , Issue.4 , pp. 266-278
    • Frurip, D.1    Britton, L.2    Fenlon, W.3    Going, J.4    Harrison, B.K.5    Niemeier, J.6
  • 6
    • 0021477978 scopus 로고
    • ODE methods for the solution of differential/algebraic systems
    • Gear C.W., and Petzold L.R. ODE methods for the solution of differential/algebraic systems. SIAM Journal of Numerical Analysis 31 (1984) 716-728
    • (1984) SIAM Journal of Numerical Analysis , vol.31 , pp. 716-728
    • Gear, C.W.1    Petzold, L.R.2
  • 8
    • 0000899289 scopus 로고
    • Thermal stability screening and reaction calorimetry-Application to runaway reaction hazard assessment and process safety management
    • Gustin J.L. Thermal stability screening and reaction calorimetry-Application to runaway reaction hazard assessment and process safety management. Journal of Loss Prevention in the Process Industries 6 5 (1993) 275-291
    • (1993) Journal of Loss Prevention in the Process Industries , vol.6 , Issue.5 , pp. 275-291
    • Gustin, J.L.1
  • 9
    • 33749858970 scopus 로고    scopus 로고
    • Gustin, J. L., & Rochina, V. (1992). Cahier de Sécurité. UIC Paris, Fascicule 12, chapitre 5, 64-70.
  • 10
    • 0036570907 scopus 로고    scopus 로고
    • On the use and misuse of detected onset temperature of calorimetric experiments for reactive chemicals
    • Hofelich T.C., and LaBarge M.S. On the use and misuse of detected onset temperature of calorimetric experiments for reactive chemicals. Journal of Loss Prevention in the Process Industries 15 3 (2002) 163-168
    • (2002) Journal of Loss Prevention in the Process Industries , vol.15 , Issue.3 , pp. 163-168
    • Hofelich, T.C.1    LaBarge, M.S.2
  • 12
    • 0024090386 scopus 로고
    • Simulation of spontaneous heating for the evaluation of the ignition temperature
    • Liang H., and Tanaka T. Simulation of spontaneous heating for the evaluation of the ignition temperature. International Chemical Engineering 28 4 (1988) 652-660
    • (1988) International Chemical Engineering , vol.28 , Issue.4 , pp. 652-660
    • Liang, H.1    Tanaka, T.2
  • 13
    • 0025405562 scopus 로고
    • Prediction of spontaneous ignition behavior of powdery organic peroxide; effect of temperature dependence of thermal conductivity
    • Ogawa T., Itagaki H., and Nabeshima J. Prediction of spontaneous ignition behavior of powdery organic peroxide; effect of temperature dependence of thermal conductivity. Journal of Hazardous Material 23 (1990) 73-87
    • (1990) Journal of Hazardous Material , vol.23 , pp. 73-87
    • Ogawa, T.1    Itagaki, H.2    Nabeshima, J.3
  • 14
    • 4243930658 scopus 로고
    • Group contribution method for predicting the potential of a chemical composition to cause an explosion
    • Seaton W.H. Group contribution method for predicting the potential of a chemical composition to cause an explosion. Journal of Chemical Education 66 5 (1989) A137-A140
    • (1989) Journal of Chemical Education , vol.66 , Issue.5
    • Seaton, W.H.1
  • 16
    • 5944259948 scopus 로고
    • Evaluation of a capillary tube sample container for differential scanning calorimetry
    • Whiting L.F., Labean M.S., and Eadie S.S. Evaluation of a capillary tube sample container for differential scanning calorimetry. Thermochimica Acta 136 (1988) 231-245
    • (1988) Thermochimica Acta , vol.136 , pp. 231-245
    • Whiting, L.F.1    Labean, M.S.2    Eadie, S.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.