메뉴 건너뛰기




Volumn 119, Issue 1-4, 2006, Pages 487-490

Method of Monte Carlo simulation verification in hadron therapy with non-tissue equivalent detectors

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ARTICLE; BIOLOGICAL MODEL; CONTROLLED STUDY; ENERGY; FAST NEUTRON THERAPY; HADRON; MONTE CARLO METHOD; NEUTRON CAPTURE THERAPY; NEUTRON DOSIMETRY; PHANTOM; QUALITY CONTROL; RADIATION ABSORPTION; RADIATION DETECTOR; RADIATION DOSE DISTRIBUTION; RADIOBIOLOGY; TISSUE DISTRIBUTION; TREATMENT PLANNING; VALIDATION PROCESS;

EID: 33749675460     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/nci618     Document Type: Article
Times cited : (10)

References (13)
  • 1
    • 0004182185 scopus 로고    scopus 로고
    • Microdosimetry and Its Applications
    • (London: Springer)
    • Rossi, H. H. and. Zaider, M. Microdosimetry and Its Applications. (London: Springer) (1996).
    • (1996)
    • Rossi, H.H.1    Zaider, M.2
  • 4
    • 0037751739 scopus 로고
    • Silicon ionization and displacement KERMA for neutron from thermal to 20 MeV
    • Roger, V. C., Harris, L., Steinman, D. K. and Bryan, D. E. Silicon ionization and displacement KERMA for neutron from thermal to 20 MeV. IEEE Trans. Nucl. Sci. NS-22(N6), 2326-2329 (1975).
    • (1975) IEEE Trans. Nucl. Sci. , vol.NS-22 , Issue.N6 , pp. 2326-2329
    • Roger, V.C.1    Harris, L.2    Steinman, D.K.3    Bryan, D.E.4
  • 5
    • 4644292664 scopus 로고    scopus 로고
    • Characterisation and use of MOSFET gamma dosimeters and silicon PIN diode neutron dosimeters for epithermal neutron beam dosimetry
    • In: (Elsevier Science Publishers) ISBN 0 444 827811
    • Carolan, M. G., Rosenfeld, A. B., Mathur, J. N. and Allen, B. J. Characterisation and use of MOSFET gamma dosimeters and silicon PIN diode neutron dosimeters for epithermal neutron beam dosimetry. In: Advances in Neutron Capture Therapy. Vol. 1, pp. 192-197 (Elsevier Science Publishers) (1997), ISBN 0 444 827811.
    • (1997) Advances in Neutron Capture Therapy , vol.1 , pp. 192-197
    • Carolan, M.G.1    Rosenfeld, A.B.2    Mathur, J.N.3    Allen, B.J.4
  • 6
    • 0030442606 scopus 로고    scopus 로고
    • An improved neutron collimator for brain tumor irradiations in clinical boron neutron capture therapy
    • Liu, H. B., Greenberg, D. D., Capala, J. and Wheeler, F. J. An improved neutron collimator for brain tumor irradiations in clinical boron neutron capture therapy. Med. Phys. 23(12), 2051-2060 (1996).
    • (1996) Med. Phys. , vol.23 , Issue.12 , pp. 2051-2060
    • Liu, H.B.1    Greenberg, D.D.2    Capala, J.3    Wheeler, F.J.4
  • 7
    • 0002999201 scopus 로고
    • Design construction and installation of an epithermal neutron beam for BNCT at the high flux reactor in Petten
    • In: Allen, B. J., Moore, D. E. and Harrington, B. V., Eds. (New York: Plenum press)
    • Moss, R., Stecher-Rasmussen, F., Ravensberg, K., Constantine, G. and Watkins, P. Design construction and installation of an epithermal neutron beam for BNCT at the high flux reactor in Petten. In: Progress in Neutron Capture therapy for Cancer. Allen, B. J., Moore, D. E. and Harrington, B. V., Eds. (New York: Plenum press) p. 63 (1992).
    • (1992) Progress in Neutron Capture Therapy for Cancer , pp. 63
    • Moss, R.1    Stecher-Rasmussen, F.2    Ravensberg, K.3    Constantine, G.4    Watkins, P.5
  • 8
    • 0039145728 scopus 로고
    • Standard practice for characterising neutron energy fluence spectra in terms of an equivalent monoenergetic neutron fluence for radiation hardness testing electronics
    • American Society for Testing and Materials. ASTM E 722-93, ASTM Committee E-10
    • American Society for Testing and Materials. Standard practice for characterising neutron energy fluence spectra in terms of an equivalent monoenergetic neutron fluence for radiation hardness testing electronics, ASTM E 722-93, ASTM Committee E-10 (1993).
    • (1993)
  • 9
    • 84899116137 scopus 로고    scopus 로고
    • GEANT4 Collaboration
    • [online]. Available on
    • GEANT4 Collaboration [online]. Available on www.info.cern.ch/asd/geant4/ geant4.html.
  • 10
    • 0032243685 scopus 로고    scopus 로고
    • Charge collection and radiation hardness of a SOI microdosimeter for space and medical application
    • Bradley, P., Rosenfeld, A.B., Lee, K. K., Jamieson, D. and Satoh, S. Charge collection and radiation hardness of a SOI microdosimeter for space and medical application. IEEE Trans. Nucl. Sci. NS-45(N6), 2700-2710 (1998).
    • (1998) IEEE Trans. Nucl. Sci. , vol.NS-45 , Issue.N6 , pp. 2700-2710
    • Bradley, P.1    Rosenfeld, A.B.2    Lee, K.K.3    Jamieson, D.4    Satoh, S.5
  • 11
    • 33749672631 scopus 로고    scopus 로고
    • Semiconductor high level dosimeters used in the SLAC gamma and neutron fields
    • SLAC-Pub-8517
    • Mao, X. C., Liu, J.C., Rosenfeld, A. B., Lerch, M. L. F., Lum, G. and Griffin, P.J. Semiconductor high level dosimeters used in the SLAC gamma and neutron fields. SLAC-Pub-8517 (2001).
    • (2001)
    • Mao, X.C.1    Liu, J.C.2    Rosenfeld, A.B.3    Lerch, M.L.F.4    Lum, G.5    Griffin, P.J.6
  • 12
    • 10744232070 scopus 로고    scopus 로고
    • New neutron dosimetry with planar silicon PIN diodes
    • Rosenfeld, A.B., Yudeley, M., Lerch, M. et al. New neutron dosimetry with planar silicon PIN diodes. IEEE Trans. Nucl. Sci. NS-50(N6), 2367-2372 (2003).
    • (2003) IEEE Trans. Nucl. Sci. , vol.NS-50 , Issue.N6 , pp. 2367-2372
    • Rosenfeld, A.B.1    Yudeley, M.2    Lerch, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.