메뉴 건너뛰기




Volumn 4142 LNCS, Issue , 2006, Pages 535-546

Felly automatic determination of morphological parameters of proximal femur from calibrated fluoroscopic images through particle filtering

Author keywords

[No Author keywords available]

Indexed keywords

ADAPTIVE FILTERING; COMPUTATION THEORY; MEDICAL IMAGING; PATIENT TREATMENT;

EID: 33749664569     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/11867661_48     Document Type: Conference Paper
Times cited : (10)

References (14)
  • 1
    • 0019785899 scopus 로고
    • Measurement accuracy of proximal femoral geometry using biplanar radiography
    • D.B. Burr D.B., Cook L.T., Martin N.L., and Asher M.: Measurement accuracy of proximal femoral geometry using biplanar radiography. J Pediatr Orthop (1981), 1(2): 171-9
    • (1981) J Pediatr Orthop , vol.1 , Issue.2 , pp. 171-179
    • Burr, D.B.1    Cook, L.T.2    Martin, N.L.3    Asher, M.4
  • 2
    • 12344307235 scopus 로고    scopus 로고
    • 3D reconstruction of the proximal femur with low-dose digital stereoradiography
    • Le Bras A., Laporte S., Bousson V., et al.: 3D reconstruction of the proximal femur with low-dose digital stereoradiography. CompAid Surg (2004), 9(3): 51-57
    • (2004) Comp Aid Surg , vol.9 , Issue.3 , pp. 51-57
    • Le Bras, A.1    Laporte, S.2    Bousson, V.3
  • 3
    • 0038371273 scopus 로고    scopus 로고
    • Computer-based periaxial rotation measurement for aligning fractured femur fragments from CT: A feasibility study
    • Ron O., Joskowicz L., Milgrom C., and Simkin A.: Computer-based periaxial rotation measurement for aligning fractured femur fragments from CT: a feasibility study. Comp Aid Surg (2002), 7: 332-341.
    • (2002) Comp Aid Surg , vol.7 , pp. 332-341
    • Ron, O.1    Joskowicz, L.2    Milgrom, C.3    Simkin, A.4
  • 4
    • 33749660741 scopus 로고    scopus 로고
    • A new system for completely MR-based computer assisted orthopaedic surgery
    • Elsevier, Amsterdam
    • Burkhardt S., Roth M., Burgkart R., and Schweikard A.: A new system for completely MR-based computer assisted orthopaedic surgery. International Congress Series(2003), Vol. 1256, page 1342, Elsevier, Amsterdam
    • (2003) International Congress Series , vol.1256 , pp. 1342
    • Burkhardt, S.1    Roth, M.2    Burgkart, R.3    Schweikard, A.4
  • 6
    • 0032822724 scopus 로고    scopus 로고
    • Fluoroscopy as an image means for computer-assisted surgical navigation
    • Hofstetter R., Slomczykowski M., Sati M., Nolte L.-P.: Fluoroscopy as an image means for computer-assisted surgical navigation. Comp Aid Surg (1999), 4(2): 65-76
    • (1999) Comp Aid Surg , vol.4 , Issue.2 , pp. 65-76
    • Hofstetter, R.1    Slomczykowski, M.2    Sati, M.3    Nolte, L.-P.4
  • 7
    • 84957604139 scopus 로고    scopus 로고
    • Contour tracking by stochastic propagation of conditional density
    • Cambridge, UK
    • Isard M. and Blake A.: Contour tracking by stochastic propagation of conditional density. ECCV 1996, pp. 343-356, Cambridge, UK
    • ECCV 1996 , pp. 343-356
    • Isard, M.1    Blake, A.2
  • 8
    • 35048832988 scopus 로고    scopus 로고
    • Human upper body pose estimation in static images
    • LNCS 3022
    • Lee M. W. and Cohen I.: Human upper body pose estimation in static images. ECCV 2004, LNCS 3022, pp. 126-138
    • ECCV 2004 , pp. 126-138
    • Lee, M.W.1    Cohen, I.2
  • 9
    • 0344983290 scopus 로고    scopus 로고
    • Tracking articulated body by dynamic Markov network
    • Nice, France
    • Wu Y., Hua G. and Yu T.: Tracking articulated body by dynamic Markov network. ICCV 2003, pp. 1094 - 1101, Nice, France
    • ICCV 2003 , pp. 1094-1101
    • Wu, Y.1    Hua, G.2    Yu, T.3
  • 12
    • 0036837501 scopus 로고    scopus 로고
    • Morphological study of the proximal femur: A new method of geometrical assessment using 3-dimensional reverse engineering
    • Mahaisavariya B., Sitthiseripratip K., Tongdee T., et al.: Morphological study of the proximal femur: a new method of geometrical assessment using 3-dimensional reverse engineering. Med Eng Phys(2002), 24: 617 - 622
    • (2002) Med Eng Phys , vol.24 , pp. 617-622
    • Mahaisavariya, B.1    Sitthiseripratip, K.2    Tongdee, T.3
  • 14
    • 0033349354 scopus 로고    scopus 로고
    • Joint Bayesian model selection and estimation of noisy sinusoids via reversible jump MCMC
    • Andrieu C. and Doucet A.: Joint Bayesian model selection and estimation of noisy sinusoids via reversible jump MCMC. IEEE T. Image Process (1999), 47(10): 456-463.
    • (1999) IEEE T. Image Process , vol.47 , Issue.10 , pp. 456-463
    • Andrieu, C.1    Doucet, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.