메뉴 건너뛰기




Volumn 6047 I, Issue , 2006, Pages

Design and evaluation of a portable continuous-wave NIR topography instrument

Author keywords

Continuous wave; Hemoglobin; Near Infrared Spectroscopy (NIRS); Optical density changes; Portable

Indexed keywords

CONTINUOUS-WAVES; MODIFIED BEER-LAMBERT LAW; NEAR INFRARED SPECTROSCOPY (NIRS); OPTICAL DENSITY CHANGES;

EID: 33749652061     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.710686     Document Type: Conference Paper
Times cited : (9)

References (6)
  • 1
    • 0038261983 scopus 로고    scopus 로고
    • Hemodynamic evoked response of the sensorimotor cortex measured noninvasively with near-infrared optical imaging
    • M. A. Franceschini, S. Fantini, J. H. Thompson, J. P. Culver and D. A. Boas, "Hemodynamic evoked response of the sensorimotor cortex measured noninvasively with near-infrared optical imaging", Psychophysiology, 40, 548-560. 2003.
    • (2003) Psychophysiology , vol.40 , pp. 548-560
    • Franceschini, M.A.1    Fantini, S.2    Thompson, J.H.3    Culver, J.P.4    Boas, D.A.5
  • 2
    • 0030843420 scopus 로고    scopus 로고
    • Non-invasive optical spectroscopy and imaging of human brain function
    • A. Villringer, and B. Chance, "Non-invasive optical spectroscopy and imaging of human brain function". Trends Neurosci., 20,435-442, 1997.
    • (1997) Trends Neurosci. , vol.20 , pp. 435-442
    • Villringer, A.1    Chance, B.2
  • 3
    • 0000743021 scopus 로고    scopus 로고
    • Design and evaluation of a continuous-wave diffuse optical tomography system
    • A. M. Siegel, J. J. A. Marota and D. A. Boas, "Design and evaluation of a continuous-wave diffuse optical tomography system", Optics Express, 4, 287-298, 1999.
    • (1999) Optics Express , vol.4 , pp. 287-298
    • Siegel, A.M.1    Marota, J.J.A.2    Boas, D.A.3
  • 4
    • 0001558388 scopus 로고    scopus 로고
    • Study of an algorithm based on model experiments and diffusion theory for a portable tissue oximeter
    • T. Shiga, K. Yamamoto, K. Tanabe, Y. Nakase and B. Chance, "Study of an algorithm based on model experiments and diffusion theory for a portable tissue oximeter", Journal of Biomedical Optics, 2, 154-161, 1997.
    • (1997) Journal of Biomedical Optics , vol.2 , pp. 154-161
    • Shiga, T.1    Yamamoto, K.2    Tanabe, K.3    Nakase, Y.4    Chance, B.5
  • 6
    • 0017571334 scopus 로고
    • 'Noninvasive infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters
    • F. F. Jobsis, '"Noninvasive infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters", Science. 198, 1264-1267, 1977.
    • (1977) Science , vol.198 , pp. 1264-1267
    • Jobsis, F.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.