메뉴 건너뛰기




Volumn 6275, Issue , 2006, Pages

Characterising the electrothermal properties of microstrip-coupled TES detectors

Author keywords

Bolometers; SQUIDs; Submillimetre Wave Detectors; Superconducting microstrip; Transition Edge Sensors

Indexed keywords

ELECTROTHERMAL PROPERTIES; SUPERCONDUCTING MICROSTRIP; TRANSITION EDGE SENSORS (TES); WAVEGUIDE HORN TECHNOLOGY;

EID: 33749621813     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.671052     Document Type: Conference Paper
Times cited : (7)

References (12)
  • 1
    • 36448999994 scopus 로고
    • An application of electrothermal feedback for high resolution cryogenic particle detection
    • K. D. Irwin, "An application of electrothermal feedback for high resolution cryogenic particle detection'''. Appl. Phys. Lett. 66, 1995.
    • (1995) Appl. Phys. Lett. , vol.66
    • Irwin, K.D.1
  • 2
    • 10444259962 scopus 로고    scopus 로고
    • SCUBA-2: A new generation submillimeter irnager for the James Clerk Maxwell Telescope
    • W.S. Holland, et al "SCUBA-2: a new generation submillimeter irnager for the James Clerk Maxwell Telescope", Millimeter and Submillimeter Detectors for Astronomy, 4855, pp. 1-18, 2003.
    • (2003) Millimeter and Submillimeter Detectors for Astronomy , vol.4855 , pp. 1-18
    • Holland, W.S.1
  • 4
    • 0042005928 scopus 로고    scopus 로고
    • First astronomical use of multiplexed transition edge bolometers
    • D.J.Benford, et al "First Astronomical Use of Multiplexed Transition Edge Bolometers", AIP-CP #605 Low Temperature Detectors, pp.589-592, 2001.
    • (2001) AIP-CP #605 Low Temperature Detectors , pp. 589-592
    • Benford, D.J.1
  • 6
    • 33749595471 scopus 로고    scopus 로고
    • C2V, P. O. Box 318,7500 AH Enschede, The Netherlands
    • C2V, P. O. Box 318,7500 AH Enschede, The Netherlands.
  • 7
    • 0037082854 scopus 로고    scopus 로고
    • A tightly coupled dc SQUID with an intermediary transformer
    • V Polushkin, et al, "A tightly coupled dc SQUID with an intermediary transformer", Phynica C, 367, 280, 2002.
    • (2002) Phynica C , vol.367 , pp. 280
    • Polushkin, V.1
  • 8
    • 3042684638 scopus 로고    scopus 로고
    • Impedance measurements and modeling of a transition-edge-sensor calorimeter
    • M. A. Lindeman, et al, "Impedance measurements and modeling of a transition-edge-sensor calorimeter", Rev. Sci. Instrum., 75, 1283, 2004.
    • (2004) Rev. Sci. Instrum. , vol.75 , pp. 1283
    • Lindeman, M.A.1
  • 9
    • 33749594928 scopus 로고    scopus 로고
    • M.D. Audley, et al, these proceeedings
    • M.D. Audley, et al, these proceeedings.
  • 10
    • 33748848168 scopus 로고    scopus 로고
    • C. Enss (Ed.), Topics Appl. Phys., Springer-Verlag Berlin Heidelberg
    • K. D. Irwin and G. C. Hilton, in Cryogenic Particle Detection, C. Enss (Ed.), Topics Appl. Phys. 99, pp. 63-149, Springer-Verlag Berlin Heidelberg, 2005.
    • (2005) Cryogenic Particle Detection , vol.99 , pp. 63-149
    • Irwin, K.D.1    Hilton, G.C.2
  • 11
    • 0042276906 scopus 로고    scopus 로고
    • Voltage-biased superconducting bolometers for infrared and mm-wave astronomy
    • Max Planck Institute of Physics, Munich, Germany, available from urg@mpprnu.inpg.de and at http://bolo.berkeley.edu.
    • A. T. Lee, J. M. Gildemeister,and P.L. Richards. "Voltage-biased superconducting bolometers for infrared and mm-wave astronomy", in Proceedings of the 17th International Workshop on Low Temperature Detectors LTD-7 Max Planck Institute of Physics, Munich, Germany, 1997 available from urg@mpprnu.inpg.de and at http://bolo.berkeley.edu.
    • (1997) Proceedings of the 17th International Workshop on Low Temperature Detectors LTD-7
    • Lee, A.T.1    Gildemeister, J.M.2    Richards, P.L.3
  • 12
    • 1642587719 scopus 로고    scopus 로고
    • Understanding TES microcalorimeter noise and energy resolution
    • W.B Tiest, et al, "Understanding TES microcalorimeter noise and energy resolution", Nucl. Iustrum. Methods Phys Res. A 520, 329, 2004.
    • (2004) Nucl. Iustrum. Methods Phys Res. A , vol.520 , pp. 329
    • Tiest, W.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.