메뉴 건너뛰기




Volumn 51, Issue 20, 2006, Pages

Direct aperture optimization of breast IMRT and the dosimetric impact of respiration motion

Author keywords

[No Author keywords available]

Indexed keywords

DIRECT APERTURE OPTIMIZATION (DAO); DOSE DISTRIBUTIONS; MOTION AMPLITUDES; RESPIRATORY MOTION;

EID: 33749621111     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/51/20/N01     Document Type: Article
Times cited : (21)

References (24)
  • 2
    • 0027991507 scopus 로고
    • The effect of the number of computed tomographic slices on dose distributions and evaluation of treatment planning systems for radiation therapy of intact breast
    • Cheng C W, Das I J and Baldassarre S 1994 The effect of the number of computed tomographic slices on dose distributions and evaluation of treatment planning systems for radiation therapy of intact breast Int. J. Radiat. Oncol. Biol. Phys. 30 183-95
    • (1994) Int. J. Radiat. Oncol. Biol. Phys. , vol.30 , pp. 183-195
    • Cheng, C.W.1    Das, I.J.2    Baldassarre, S.3
  • 3
    • 0038705898 scopus 로고    scopus 로고
    • Inverse planning for intensity-modulated arc therapy using direct aperture optimization
    • Earl M A, Shepard D M, Naqvi S, Li X A and Yu C X 2003 Inverse planning for intensity-modulated arc therapy using direct aperture optimization Phys. Med. Biol. 48 1075-89
    • (2003) Phys. Med. Biol. , vol.48 , Issue.8 , pp. 1075-1089
    • Earl, M.A.1    Shepard, D.M.2    Naqvi, S.3    Li, X.A.4    Yu, C.X.5
  • 8
    • 0030047783 scopus 로고    scopus 로고
    • Respiration gated radiotherapy treatment: A technical study
    • Kubo H D and Hill B C 1996 Respiration gated radiotherapy treatment: a technical study Phys. Med. Biol. 41 83-91
    • (1996) Phys. Med. Biol. , vol.41 , Issue.1 , pp. 83-91
    • Kubo, H.D.1    Hill, B.C.2
  • 11
    • 0032941481 scopus 로고    scopus 로고
    • A method for incorporating organ motion due to breathing into 3D dose calculation
    • Lujan A E, Larsen E W, Balter J M and Kaken R K T 1999 A method for incorporating organ motion due to breathing into 3D dose calculation Med. Phys. 26 715-20
    • (1999) Med. Phys. , vol.26 , Issue.5 , pp. 715-720
    • Lujan, A.E.1    Larsen, E.W.2    Balter, J.M.3    Kaken, R.K.T.4
  • 12
    • 13844266128 scopus 로고    scopus 로고
    • Hybrid IMRT plans-concurrently treating conventional and IMRT beams for improved breast irradiation and reduced planning time
    • Mayo C S, Urie M M and Fitzgerad T J 2005 Hybrid IMRT plans-concurrently treating conventional and IMRT beams for improved breast irradiation and reduced planning time Int. J. Radiat. Oncol. Biol. Phys. 61 922-32
    • (2005) Int. J. Radiat. Oncol. Biol. Phys. , vol.61 , Issue.3 , pp. 922-932
    • Mayo, C.S.1    Urie, M.M.2    Fitzgerad, T.J.3
  • 13
    • 0042674085 scopus 로고    scopus 로고
    • Convolution/superposition using the Monte Carlo method
    • Naqvi S A, Earl M A and Shepard D M 2003 Convolution/superposition using the Monte Carlo method Phys. Med. Biol. 48 2101-21
    • (2003) Phys. Med. Biol. , vol.48 , Issue.14 , pp. 2101-2121
    • Naqvi, S.A.1    Earl, M.A.2    Shepard, D.M.3
  • 14
    • 17844389898 scopus 로고    scopus 로고
    • A stochastic convolution/superposition method with isocenter sampling to evaluate intrafraction motion effects in IMRT
    • Naqvi S A and D'Souza W D 2005 A stochastic convolution/superposition method with isocenter sampling to evaluate intrafraction motion effects in IMRT Med. Phys. 32 1156-63
    • (2005) Med. Phys. , vol.32 , Issue.4 , pp. 1156-1163
    • Naqvi, S.A.1    D'Souza, W.D.2
  • 15
    • 0036535315 scopus 로고    scopus 로고
    • Issues in respiratory motion compensation during external-beam radiotherapy
    • Ozhasoglu C and Murphy M J 2002 Issues in respiratory motion compensation during external-beam radiotherapy Int. J. Radiat. Oncol. Biol. Phys. 52 1389-99
    • (2002) Int. J. Radiat. Oncol. Biol. Phys. , vol.52 , Issue.5 , pp. 1389-1399
    • Ozhasoglu, C.1    Murphy, M.J.2
  • 16
    • 0037296146 scopus 로고    scopus 로고
    • Significant reductions in heart and lung doses using deep inspiration breath hold with active breathing control and intensity-modulated radiation therapy for patients treated with locoregional breast irradiation
    • Remouchamps V M, Vicini F A, Martinez A A, Sharpe M B, Yan D, Kestin L L and Wong J W 2003a Significant reductions in heart and lung doses using deep inspiration breath hold with active breathing control and intensity-modulated radiation therapy for patients treated with locoregional breast irradiation Int. J. Radiat. Oncol. Biol. Phys. 55 392-406
    • (2003) Int. J. Radiat. Oncol. Biol. Phys. , vol.55 , Issue.2 , pp. 392-406
    • Remouchamps, V.M.1    Vicini, F.A.2    Martinez, A.A.3    Sharpe, M.B.4    Yan, D.5    Kestin, L.L.6    Wong, J.W.7
  • 17
    • 0037606000 scopus 로고    scopus 로고
    • Initial clinical experience with moderate deep inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy
    • Remouchamps V M, Letts N, Vicini F A, Sharpe M B, Kestin L L, Chen P Y, Martinez A A and Wong J W 2003b Initial clinical experience with moderate deep inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy Int. J. Radiat. Oncol. Biol. Phys. 56 704-15
    • (2003) Int. J. Radiat. Oncol. Biol. Phys. , vol.56 , Issue.3 , pp. 704-715
    • Remouchamps, V.M.1    Letts, N.2    Vicini, F.A.3    Sharpe, M.B.4    Kestin, L.L.5    Chen, P.Y.6    Martinez, A.A.7    Wong, J.W.8
  • 19
    • 0035989958 scopus 로고    scopus 로고
    • Direct aperture optimization: A turnkey solution for step-and-shoot IMRT
    • Shepard D M, Earl M A, Li X A, Naqvi S A and Yu C X 2002 Direct aperture optimization: a turnkey solution for step-and-shoot IMRT Med. Phys. 29 1007-18
    • (2002) Med. Phys. , vol.29 , Issue.6 , pp. 1007-1018
    • Shepard, D.M.1    Earl, M.A.2    Li, X.A.3    Naqvi, S.A.4    Yu, C.X.5
  • 20
    • 1842581284 scopus 로고    scopus 로고
    • The use of intensity modulated radiation therapy in the treatment of breast cancer: Evolving definition, misdirected criticism, and untoward effects
    • Vicini F A, Sharpe M, Kestin L L, Wong J W, Remouchamps V M and Martinez A A 2004 The use of intensity modulated radiation therapy in the treatment of breast cancer: evolving definition, misdirected criticism, and untoward effects Int. J. Radiat. Oncol. Biol. Phys. 58 1642-4
    • (2004) Int. J. Radiat. Oncol. Biol. Phys. , vol.58 , Issue.5 , pp. 1642-1644
    • Vicini, F.A.1    Sharpe, M.2    Kestin, L.L.3    Wong, J.W.4    Remouchamps, V.M.5    Martinez, A.A.6
  • 21
    • 0141504127 scopus 로고    scopus 로고
    • Validation of active breathing control in patients with non-small-cell lung cancer to be treated with CHARTWEL
    • Wilson E M, Williams F J, Lyn B E, Wong J W and Aird E G A 2003 Validation of active breathing control in patients with non-small-cell lung cancer to be treated with CHARTWEL Int. J. Radiat. Oncol. Biol. Phys. 57 864-74
    • (2003) Int. J. Radiat. Oncol. Biol. Phys. , vol.57 , Issue.3 , pp. 864-874
    • Wilson, E.M.1    Williams, F.J.2    Lyn, B.E.3    Wong, J.W.4    Aird, E.G.A.5
  • 24
    • 0031892627 scopus 로고    scopus 로고
    • The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation
    • Yu C Y, Jaffray D A and Wong J W 1998 The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation Phys. Med. Biol. 43 91-104
    • (1998) Phys. Med. Biol. , vol.43 , Issue.1 , pp. 91-104
    • Yu, C.Y.1    Jaffray, D.A.2    Wong, J.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.