메뉴 건너뛰기




Volumn 41, Issue 10, 2006, Pages 985-992

Noninvasive monitoring of chest wall movement in infants using laser

Author keywords

Chest wall movement; Infant; Laser; Lung function; Noninvasive

Indexed keywords

ABDOMEN; ARTICLE; BREATHING MECHANICS; CHILD; CLINICAL ARTICLE; COMPARTMENT MODEL; CONTROLLED STUDY; HUMAN; IMPEDANCE PLETHYSMOGRAPHY; INFANT; LASER; NEWBORN; NON INVASIVE MEASUREMENT; PRIORITY JOURNAL; REPRODUCIBILITY; RESPIRATORY TRACT DISEASE; SENSOR; SLEEP; THORAX; THORAX WALL; TIDAL VOLUME;

EID: 33749574311     PISSN: 87556863     EISSN: 10990496     Source Type: Journal    
DOI: 10.1002/ppul.20482     Document Type: Article
Times cited : (7)

References (13)
  • 1
    • 0014060388 scopus 로고
    • Measurement of the separate volume changes of rib cage and abdomen during breathing
    • Konno K, Mead J. Measurement of the separate volume changes of rib cage and abdomen during breathing. J Appl Physiol 1966;22:407-422.
    • (1966) J Appl Physiol , vol.22 , pp. 407-422
    • Konno, K.1    Mead, J.2
  • 2
    • 0026546457 scopus 로고
    • Analysis of human chest wall motion using a two-compartment rib cage model
    • Ward ME, Ward JW, Macklem PT. Analysis of human chest wall motion using a two-compartment rib cage model. J Appl Physiol 1992;72:1338-1347.
    • (1992) J Appl Physiol , vol.72 , pp. 1338-1347
    • Ward, M.E.1    Ward, J.W.2    Macklem, P.T.3
  • 3
    • 0022270338 scopus 로고
    • ELITE: A digital dedicated hardware system for movement analysis via real-time TV signal processing
    • Ferrigno G, Peddoti A. ELITE: a digital dedicated hardware system for movement analysis via real-time TV signal processing. IEEE Trans. Biomed Eng 1985;32:943-950.
    • (1985) IEEE Trans. Biomed Eng , vol.32 , pp. 943-950
    • Ferrigno, G.1    Peddoti, A.2
  • 6
    • 0030808361 scopus 로고    scopus 로고
    • Measurements of PEEP-induced changes in lung volume
    • Uhlig T, Kondo T, Sly P. Measurements of PEEP-induced changes in lung volume. Chest 1997;112:107-112.
    • (1997) Chest , vol.112 , pp. 107-112
    • Uhlig, T.1    Kondo, T.2    Sly, P.3
  • 7
    • 0033773074 scopus 로고    scopus 로고
    • Specifications for equipment used for infant pulmonary function testing
    • Frey U, Stocks J, Coates A, Sly P, Bates JHT. Specifications for equipment used for infant pulmonary function testing. Eur Respir J 2000;16:731-740.
    • (2000) Eur Respir J , vol.16 , pp. 731-740
    • Frey, U.1    Stocks, J.2    Coates, A.3    Sly, P.4    Bates, J.H.T.5
  • 8
    • 0034518888 scopus 로고    scopus 로고
    • Specifications for signal processing and data handling used for infant pulmonary function testing
    • Frey U, Stocks J, Sly JP, Bates J. Specifications for signal processing and data handling used for infant pulmonary function testing- Eur Respir J 2000;16:1016-1022.
    • (2000) Eur Respir J , vol.16 , pp. 1016-1022
    • Frey, U.1    Stocks, J.2    Sly, J.P.3    Bates, J.4
  • 9
    • 0034483387 scopus 로고    scopus 로고
    • Tidal breath analysis for infant pulmonary function testing
    • Bates JHT, Schmalisch G, Filbrun D, Stocks J. Tidal breath analysis for infant pulmonary function testing. Eur Respir J 2000;16:1180-1192.
    • (2000) Eur Respir J , vol.16 , pp. 1180-1192
    • Bates, J.H.T.1    Schmalisch, G.2    Filbrun, D.3    Stocks, J.4
  • 10
    • 0027247761 scopus 로고
    • Tidal volume measurements in newborns using respiratory inductive plethysmography
    • Adams JA, Zabaleta IA, Stroh D, Johnson P, Sackner A. Tidal volume measurements in newborns using respiratory inductive plethysmography. Am Rev Respir Dis 1993;148:585-588.
    • (1993) Am Rev Respir Dis , vol.148 , pp. 585-588
    • Adams, J.A.1    Zabaleta, I.A.2    Stroh, D.3    Johnson, P.4    Sackner, A.5
  • 11
    • 0025213359 scopus 로고
    • Changes in the contribution of the rib cage to tidal breathing during infancy
    • Hershenson MB, Colin AA, Wohl EB, Stark AR. Changes in the contribution of the rib cage to tidal breathing during infancy. Am Rev Respir Dis 1990;141:922-925.
    • (1990) Am Rev Respir Dis , vol.141 , pp. 922-925
    • Hershenson, M.B.1    Colin, A.A.2    Wohl, E.B.3    Stark, A.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.