메뉴 건너뛰기




Volumn 2006, Issue , 2006, Pages

FDK half-scan with a heuristic weighting scheme on a flat panel detector-based cone beam CT (FDKHSCW)

Author keywords

[No Author keywords available]

Indexed keywords


EID: 33749531928     PISSN: 16874188     EISSN: 16874196     Source Type: Journal    
DOI: 10.1155/IJBI/2006/83983     Document Type: Article
Times cited : (15)

References (17)
  • 1
    • 0034917860 scopus 로고    scopus 로고
    • Half-scan cone-beam CT fluoroscopy with multiple x-ray sources
    • Y. Liu H. Liu Y. Wang G. Wang Half-scan cone-beam CT fluoroscopy with multiple x-ray sources. Medical Physics 28 7 2001 1466 1471
    • (2001) Medical Physics , vol.28 , Issue.7 , pp. 1466-1471
    • Liu, Y.1    Liu, H.2    Wang, Y.3    Wang, G.4
  • 2
    • 0037394932 scopus 로고    scopus 로고
    • Temporal resolution and the evaluation of candidate algorithms for four-dimensional CT
    • ktaguchi@aol.com
    • K. Taguchi ktaguchi@aol.com Temporal resolution and the evaluation of candidate algorithms for four-dimensional CT. Medical Physics 30 4 2003 640 650
    • (2003) Medical Physics , vol.30 , Issue.4 , pp. 640-650
    • Taguchi, K.1
  • 3
    • 0027967106 scopus 로고
    • Half-scan cone-beam x-ray microtomography formula
    • G. Wang Y. Liu T. H. Lin P. C. Cheng Half-scan cone-beam x-ray microtomography formula. Scanning 16 4 1994 216 220
    • (1994) Scanning , vol.16 , Issue.4 , pp. 216-220
    • Wang, G.1    Liu, Y.2    Lin, T.H.3    Cheng, P.C.4
  • 4
    • 0034257867 scopus 로고    scopus 로고
    • Feldkamp-type cone-beam tomography in the wavelet framework
    • S. Zhao G. Wang Feldkamp-type cone-beam tomography in the wavelet framework. IEEE Transactions on Medical Imaging 19 9 2000 922 929
    • (2000) IEEE Transactions on Medical Imaging , vol.19 , Issue.9 , pp. 922-929
    • Zhao, S.1    Wang, G.2
  • 5
    • 0026838538 scopus 로고
    • A cone-beam filtered backprojection reconstruction algorithm for cardiac single photon emission computed tomography
    • G. T. Gullberg G. L. Zeng A cone-beam filtered backprojection reconstruction algorithm for cardiac single photon emission computed tomography. IEEE Transactions on Medical Imaging 1992 11 1 91 101
    • (1992) IEEE Transactions on Medical Imaging , vol.11 , Issue.1 , pp. 91-101
    • Gullberg, G.T.1    Zeng, G.L.2
  • 6
    • 0036033728 scopus 로고    scopus 로고
    • Image reconstruction from cone-beam data on a circular short-scan
    • Proceedings of SPIE San Diego, Calif, USA
    • F. Noo D. J. Heuscher Image reconstruction from cone-beam data on a circular short-scan. Medical Imaging 2002: Image Processing Proceedings of SPIE 4684 2002 San Diego, Calif, USA 50 59
    • (2002) Medical Imaging 2002: Image Processing , vol.4684 , pp. 50-59
    • Noo, F.1    Heuscher, D.J.2
  • 7
    • 0037395146 scopus 로고    scopus 로고
    • A Grangeat-type half-scan algorithm for cone-beam CT
    • swlee@ct.radiology.uiowa.edu ge@ct.radiology.uiowa.edu
    • S. W. Lee swlee@ct.radiology.uiowa.edu G. Wang ge@ct.radiology.uiowa.edu A Grangeat-type half-scan algorithm for cone-beam CT. Medical Physics 30 4 2003 689 700
    • (2003) Medical Physics , vol.30 , Issue.4 , pp. 689-700
    • Lee, S.W.1    Wang, G.2
  • 8
    • 0002018761 scopus 로고
    • Mathematical framework of cone beam 3D reconstruction via the first derivative of the Radon transform
    • Lecture Notes in MathematicsSpringer Berlin, Germany
    • P. Grangeat G. T. Herman A. K. Luis F. Natterer Mathematical framework of cone beam 3D reconstruction via the first derivative of the Radon transform. Mathematical Methods in Tomography Lecture Notes in Mathematics Springer Berlin, Germany 1991 66 97
    • (1991) Mathematical Methods in Tomography , pp. 66-97
    • Grangeat, P.1    Herman, G.T.2    Luis, A.K.3    Natterer, F.4
  • 9
    • 0020030616 scopus 로고
    • Optimal short scan convolution reconstruction for fan beam CT
    • D. L. Parker Optimal short scan convolution reconstruction for fan beam CT. Medical Physics 9 2 1982 254 257
    • (1982) Medical Physics , vol.9 , Issue.2 , pp. 254-257
    • Parker, D.L.1
  • 12
    • 23844497876 scopus 로고    scopus 로고
    • Image noise due to quantum fluctuations in flat-panel detector based cone-beam CT imaging
    • yan_zhang@urmc.rochester.edu ruola_ning@urmc.rochester.edu Proceedings of SPIE San Diego, Calif, USA
    • Y. Zhang yan_zhang@urmc.rochester.edu R. Ning ruola_ning@urmc.rochester. edu D. Conover Y. Yu Image noise due to quantum fluctuations in flat-panel detector based cone-beam CT imaging. Medical Imaging 2005: Physics of Medical Imaging Proceedings of SPIE 5745 2005 San Diego, Calif, USA 656 663
    • (2005) Medical Imaging 2005: Physics of Medical Imaging , vol.5745 , pp. 656-663
    • Zhang, Y.1    Ning, R.2    Conover, D.3    Yu, Y.4
  • 13
    • 0033993737 scopus 로고    scopus 로고
    • A method for including redundant data in computed tomography
    • M. D. Silver A method for including redundant data in computed tomography. Medical Physics 27 4 2000 773 774
    • (2000) Medical Physics , vol.27 , Issue.4 , pp. 773-774
    • Silver, M.D.1
  • 14
    • 0343340400 scopus 로고    scopus 로고
    • 3D cone-beam CT reconstruction for circular trajectories
    • M. Grass Th. Kōhler R. Proksa 3D cone-beam CT reconstruction for circular trajectories. Physics in Medicine and Biology 45 2 2000 329 347
    • (2000) Physics in Medicine and Biology , vol.45 , Issue.2 , pp. 329-347
    • Grass, M.1    Kohler, Th.2    Proksa, R.3
  • 15
    • 0003859055 scopus 로고    scopus 로고
    • Linkoeping Studies in Science and Technology Dissertation 672Linkoeping University Linkoeping, Sweden
    • H. Turbell Cone-beam reconstruction using filtered backprojection. 2001 Linkoeping Studies in Science and Technology Dissertation 672 Linkoeping University Linkoeping, Sweden
    • (2001) Cone-beam Reconstruction Using Filtered Backprojection
    • Turbell, H.1
  • 16
    • 0035996482 scopus 로고    scopus 로고
    • X-ray micro-CT with a displaced detector array
    • G. Wang X-ray micro-CT with a displaced detector array. Medical Physics 29 7 2002 1634 1636
    • (2002) Medical Physics , vol.29 , Issue.7 , pp. 1634-1636
    • Wang, G.1
  • 17
    • 23744435329 scopus 로고    scopus 로고
    • A three-dimensional weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory
    • xiangyang.tang@med.ge.com
    • X. Tang xiangyang.tang@med.ge.com J. Hsieh A. Hagiwara R. A. Nilsen J.-B. Thibault E. Drapkin A three-dimensional weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory. Physics in Medicine and Biology 50 16 2005 3889 3905
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.16 , pp. 3889-3905
    • Tang, X.1    Hsieh, J.2    Hagiwara, A.3    Nilsen, R.A.4    Thibault, J.-B.5    Drapkin, E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.