메뉴 건너뛰기




Volumn 31, Issue 21, 2006, Pages 2454-2462

Wear and corrosion in retrieved thoracolumbar posterior internal fixation

Author keywords

Corrosion; Interconnectors; Pedicle screw; Retrieval study; Revision surgery; Rod; Spine implant; Stainless steel; Titanium; Wear

Indexed keywords

STAINLESS STEEL; TITANIUM;

EID: 33749528814     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/01.brs.0000239132.16484.be     Document Type: Article
Times cited : (38)

References (28)
  • 1
    • 0142089924 scopus 로고    scopus 로고
    • Spinal implant debris-induced osteolysis
    • Hallab NJ, Cunningham BW, Jacobs JJ. Spinal implant debris-induced osteolysis. Spine 2003;28(suppl):125-38.
    • (2003) Spine , vol.28 , Issue.SUPPL. , pp. 125-138
    • Hallab, N.J.1    Cunningham, B.W.2    Jacobs, J.J.3
  • 2
    • 0037106124 scopus 로고    scopus 로고
    • The effect of titanium particulate on development and maintenance of a posterolateral spinal arthrodesis
    • Cunningham BW, Orbegoso CM, Dmitriev AE, et al. The effect of titanium particulate on development and maintenance of a posterolateral spinal arthrodesis. Spine 2002;27:1971-81.
    • (2002) Spine , vol.27 , pp. 1971-1981
    • Cunningham, B.W.1    Orbegoso, C.M.2    Dmitriev, A.E.3
  • 3
    • 0642340404 scopus 로고    scopus 로고
    • The effect of spinal instrumentation particulate wear debris: An in vivo rabbit model and applied clinical study of retrieved instrumentation cases
    • Cunningham BW, Orbegoso CM, Dmitriev AE, et al. The effect of spinal instrumentation particulate wear debris: an in vivo rabbit model and applied clinical study of retrieved instrumentation cases. Spine J 2003;3:19-32.
    • (2003) Spine J , vol.3 , pp. 19-32
    • Cunningham, B.W.1    Orbegoso, C.M.2    Dmitriev, A.E.3
  • 4
    • 0028302626 scopus 로고
    • A histologic study of soft-tissue reactions to spinal implants
    • Mody DR, Esses SI, Heggeness MH. A histologic study of soft-tissue reactions to spinal implants. Spine 1994;19:1153-6.
    • (1994) Spine , vol.19 , pp. 1153-1156
    • Mody, D.R.1    Esses, S.I.2    Heggeness, M.H.3
  • 6
    • 0025642529 scopus 로고
    • Cementless total joint arthroplasty prostheses with titanium-alloy articular surfaces: A human retrieval analysis
    • Nasser S, Campbell PA, Kilgus D, et al. Cementless total joint arthroplasty prostheses with titanium-alloy articular surfaces: a human retrieval analysis. Clin Orthop 1990;261:171-85.
    • (1990) Clin Orthop , vol.261 , pp. 171-185
    • Nasser, S.1    Campbell, P.A.2    Kilgus, D.3
  • 7
    • 0027094534 scopus 로고
    • Histopathological effects of ultra-high-molecular-weight polyethylene and metal wear debris in porous and cemented surface replacements
    • St. John KR, ed. [ASTM STP 1144]. Philadelphia: American Society for Testing and Materials
    • Campbell P, Nasser S, Kossovsky N, et al. Histopathological effects of ultra-high-molecular-weight polyethylene and metal wear debris in porous and cemented surface replacements. In: St. John KR, ed. Particulate Debris From Medical Implants: Mechanisms of Formation and Biological Consequences [ASTM STP 1144]. Philadelphia: American Society for Testing and Materials, 1992:38-51.
    • (1992) Particulate Debris from Medical Implants: Mechanisms of Formation and Biological Consequences , pp. 38-51
    • Campbell, P.1    Nasser, S.2    Kossovsky, N.3
  • 8
    • 0027060321 scopus 로고
    • Particulate associated osteolysis in titanium-base alloy cementless total hip replacement
    • St. John KR, ed. [ASTM STP 1144]. Philadelphia: American Society for Testing and Materials
    • Jacobs JJ, Urban RM, Schajowicz F, et al. Particulate associated osteolysis in titanium-base alloy cementless total hip replacement. In: St. John KR, ed. Particulate Debris From Medical Implants: Mechanisms of Formation and Biological Consequences [ASTM STP 1144]. Philadelphia: American Society for Testing and Materials, 1992:52-60.
    • (1992) Particulate Debris from Medical Implants: Mechanisms of Formation and Biological Consequences , pp. 52-60
    • Jacobs, J.J.1    Urban, R.M.2    Schajowicz, F.3
  • 9
    • 0033134799 scopus 로고    scopus 로고
    • Metal debris from titanium spinal implants
    • Wang JC, Yu WD, Sandhu HS, et al. Metal debris from titanium spinal implants. Spine 1999;24:899-903.
    • (1999) Spine , vol.24 , pp. 899-903
    • Wang, J.C.1    Yu, W.D.2    Sandhu, H.S.3
  • 10
    • 0033562411 scopus 로고    scopus 로고
    • Corrosion on an internal spinal fixator system
    • Vieweg U, van Roost D, Wolf HK, et al. Corrosion on an internal spinal fixator system. Spine 1999;24:946-51.
    • (1999) Spine , vol.24 , pp. 946-951
    • Vieweg, U.1    Van Roost, D.2    Wolf, H.K.3
  • 11
    • 0024603840 scopus 로고
    • Role of corrosion in Harrington and Luque rods failure
    • Prikryl M, Srivastava SC, Viviani GR, et al. Role of corrosion in Harrington and Luque rods failure. Biomaterials 1989;10:109-17.
    • (1989) Biomaterials , vol.10 , pp. 109-117
    • Prikryl, M.1    Srivastava, S.C.2    Viviani, G.R.3
  • 12
    • 0023636705 scopus 로고
    • Biodegradation phenomena observed in vivo and in vitro spinal instrumentation systems
    • Bidez MW, Lucas LC, Lemons JE, et al. Biodegradation phenomena observed in vivo and in vitro spinal instrumentation systems. Spine 1987;12:605-8.
    • (1987) Spine , vol.12 , pp. 605-608
    • Bidez, M.W.1    Lucas, L.C.2    Lemons, J.E.3
  • 13
    • 0020364184 scopus 로고
    • Corrosion of the Harrington's instrumentation and biological behaviour of the rod-human spine system
    • Aulisa L, di Benedetto A, Vinciguerra A, et al. Corrosion of the Harrington's instrumentation and biological behaviour of the rod-human spine system. Biomaterials 1982;3:246-9.
    • (1982) Biomaterials , vol.3 , pp. 246-249
    • Aulisa, L.1    Di Benedetto, A.2    Vinciguerra, A.3
  • 14
    • 0038580631 scopus 로고    scopus 로고
    • Late infection in patients with scoliosis treated with spinal instrumentation
    • Soultanis K, Mantelos G, Pagiatakis A, et al. Late infection in patients with scoliosis treated with spinal instrumentation. Clin Orthop 2003:116-23.
    • (2003) Clin Orthop , pp. 116-123
    • Soultanis, K.1    Mantelos, G.2    Pagiatakis, A.3
  • 15
    • 33749512569 scopus 로고    scopus 로고
    • Mechanisms of titanium release from posterior cervical spine plates in a canine model based on computational and biocompatibility studies
    • Soboyejo W, ed. Winterthur, Switzerland: Trans Tech
    • Villarraga ML, Anderson RC, Hart RT, et al. Mechanisms of titanium release from posterior cervical spine plates in a canine model based on computational and biocompatibility studies. In: Soboyejo W, ed. Functional Biomaterials. Winterthur, Switzerland: Trans Tech, 2000.
    • (2000) Functional Biomaterials
    • Villarraga, M.L.1    Anderson, R.C.2    Hart, R.T.3
  • 16
    • 3342989317 scopus 로고    scopus 로고
    • Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?
    • Serhan H, Slivka M, Albert T, et al. Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern? Spine J 2004;4:379-87.
    • (2004) Spine J , vol.4 , pp. 379-387
    • Serhan, H.1    Slivka, M.2    Albert, T.3
  • 17
    • 0036066389 scopus 로고    scopus 로고
    • Spinal cage retrieval and assessment of biologic response
    • Brodke DS, Willie BM, Maaranen EA, et al. Spinal cage retrieval and assessment of biologic response. J Spinal Disord Tech 2002;15:206-12.
    • (2002) J Spinal Disord Tech , vol.15 , pp. 206-212
    • Brodke, D.S.1    Willie, B.M.2    Maaranen, E.A.3
  • 18
    • 0037313302 scopus 로고    scopus 로고
    • Histology of tissues within retrieved human titanium mesh cages
    • discussion 254
    • Togawa D, Bauer TW, Lieberman IH, et al. Histology of tissues within retrieved human titanium mesh cages. Spine 2003;28:246-53; discussion 254.
    • (2003) Spine , vol.28 , pp. 246-253
    • Togawa, D.1    Bauer, T.W.2    Lieberman, I.H.3
  • 19
    • 0348223825 scopus 로고    scopus 로고
    • Lumbar intervertebral body fusion cages: Histological evaluation of clinically failed cages retrieved from humans
    • Togawa D, Bauer TW, Lieberman IH, et al. Lumbar intervertebral body fusion cages: histological evaluation of clinically failed cages retrieved from humans. J Bone Joint Surg Am 2004;86:70-9.
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 70-79
    • Togawa, D.1    Bauer, T.W.2    Lieberman, I.H.3
  • 20
    • 0038046347 scopus 로고    scopus 로고
    • Metal concentrations in the serum and hair of patients with titanium alloy spinal implants
    • Kasai Y, Iida R, Uchida A. Metal concentrations in the serum and hair of patients with titanium alloy spinal implants. Spine 2003;28:1320-6.
    • (2003) Spine , vol.28 , pp. 1320-1326
    • Kasai, Y.1    Iida, R.2    Uchida, A.3
  • 21
    • 0034671279 scopus 로고    scopus 로고
    • SF-36 health survey update
    • Ware JE Jr. SF-36 health survey update. Spine 2000;25:3130-9.
    • (2000) Spine , vol.25 , pp. 3130-3139
    • Ware Jr., J.E.1
  • 22
    • 0034128579 scopus 로고    scopus 로고
    • Influence of stability and mechanical properties of a spinal fixation device on production of wear debris particles in vivo
    • Mochida Y, Bauer TW, Nitto H, et al. Influence of stability and mechanical properties of a spinal fixation device on production of wear debris particles in vivo. J Biomed Mater Res 2000;53:193-8.
    • (2000) J Biomed Mater Res , vol.53 , pp. 193-198
    • Mochida, Y.1    Bauer, T.W.2    Nitto, H.3
  • 23
    • 18844473121 scopus 로고
    • Spinal internal fixator: Analysis of problems in 28 cases
    • Sim E. Spinal internal fixator: analysis of problems in 28 cases. Wien Klin Wochenschr 1992;104:349-55.
    • (1992) Wien Klin Wochenschr , vol.104 , pp. 349-355
    • Sim, E.1
  • 25
    • 0027304350 scopus 로고
    • Static and cyclical biomechanical analysis of pedicle screw spinal constructs
    • Cunningham BW, Sefter JC, Shono Y, et al. Static and cyclical biomechanical analysis of pedicle screw spinal constructs. Spine 1993;18:1677-88.
    • (1993) Spine , vol.18 , pp. 1677-1688
    • Cunningham, B.W.1    Sefter, J.C.2    Shono, Y.3
  • 26
    • 0033496103 scopus 로고    scopus 로고
    • Strength and fatigue resistance of thoracolumbar spine implants: An experimental study of selected clinical devices
    • Stambough JL, El Khatib F, Genaidy AM, et al. Strength and fatigue resistance of thoracolumbar spine implants: an experimental study of selected clinical devices. J Spinal Disord 1999;12:410-4.
    • (1999) J Spinal Disord , vol.12 , pp. 410-414
    • Stambough, J.L.1    El Khatib, F.2    Genaidy, A.M.3
  • 27
    • 0034397885 scopus 로고    scopus 로고
    • 2000 Volvo Award winner in biomechanical studies: Monitoring in vivo implant loads with a telemeterized internal spinal fixation device
    • Rohlmann A, Graichen F, Weber U, et al. 2000 Volvo Award winner in biomechanical studies: Monitoring in vivo implant loads with a telemeterized internal spinal fixation device. Spine 2000;25:2981-6.
    • (2000) Spine , vol.25 , pp. 2981-2986
    • Rohlmann, A.1    Graichen, F.2    Weber, U.3
  • 28
    • 3242729339 scopus 로고    scopus 로고
    • Risk factors for adjacent segment degeneration after PLIF
    • Okuda S, Iwasaki M, Miyauchi A, et al. Risk factors for adjacent segment degeneration after PLIF. Spine 2004;29:1535-40.
    • (2004) Spine , vol.29 , pp. 1535-1540
    • Okuda, S.1    Iwasaki, M.2    Miyauchi, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.