메뉴 건너뛰기




Volumn 22, Issue 1, 2006, Pages 49-52

Aortic endografts: Detecting endoleaks using contrast-enhanced ultrasound

Author keywords

Aorta; Contrast; Endoleak; Intervention; Microbubbles; Stent graft; Ultrasound

Indexed keywords

CONTRAST MEDIUM; SHU 508;

EID: 33749425669     PISSN: 08948771     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (7)

References (23)
  • 1
    • 0030947672 scopus 로고    scopus 로고
    • Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: Classification, incidence, diagnosis, and management
    • White GH, Yu W, May J, et al. Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: classification, incidence, diagnosis, and management. J Endovasc Surg. 1997:4152-4168.
    • (1997) J Endovasc Surg , pp. 4152-4168
    • White, G.H.1    Yu, W.2    May, J.3
  • 2
    • 0031647176 scopus 로고    scopus 로고
    • Type III and type IV endoleak: Toward a complete definition of blood flow in the sac after endoluminal AAA repair
    • White GH, May J, Waugh RC, et al. Type III and type IV endoleak: toward a complete definition of blood flow in the sac after endoluminal AAA repair. J Endovasc Surg. 1998;5:305-309.
    • (1998) J Endovasc Surg , vol.5 , pp. 305-309
    • White, G.H.1    May, J.2    Waugh, R.C.3
  • 3
    • 8844238411 scopus 로고    scopus 로고
    • Midterm results of a multicenter trial of the Powerlink bifurcated system for endovascular aortic aneurysm repair
    • Endologix Investigators. November
    • Carpenter JP, Endologix Investigators. Midterm results of a multicenter trial of the Powerlink bifurcated system for endovascular aortic aneurysm repair. J Vasc Surg. November 2004;40(5):849-859.
    • (2004) J Vasc Surg , vol.40 , Issue.5 , pp. 849-859
    • Carpenter, J.P.1
  • 4
    • 9144251638 scopus 로고    scopus 로고
    • Multicenter pivotal trial results of the Lifepath System for endovascular aortic aneurysm repair
    • January
    • Carpenter JP, Anderson WN, Brewster DC, et al. Multicenter pivotal trial results of the Lifepath System for endovascular aortic aneurysm repair. J Vasc Surg. January 2004;39(1):34-43.
    • (2004) J Vasc Surg , vol.39 , Issue.1 , pp. 34-43
    • Carpenter, J.P.1    Anderson, W.N.2    Brewster, D.C.3
  • 5
    • 0037326088 scopus 로고    scopus 로고
    • A multicenter controlled clinical trial of open versus endovascular treatment of abdominal aortic aneurysm
    • February
    • Matsumura JS, Brewster DC, Makaroun MS. A multicenter controlled clinical trial of open versus endovascular treatment of abdominal aortic aneurysm. J Vasc Surg. February 2003;37(2):262-271.
    • (2003) J Vasc Surg , vol.37 , Issue.2 , pp. 262-271
    • Matsumura, J.S.1    Brewster, D.C.2    Makaroun, M.S.3
  • 6
    • 0036998784 scopus 로고    scopus 로고
    • The Zenith aortic stentgraft: A 5-year single-center experience
    • December
    • Alric P, Hinchliff RJ, MacSweeney ST, et al. The Zenith aortic stentgraft: a 5-year single-center experience. J Endovasc Ther. December 2002;9(6):719-728.
    • (2002) J Endovasc Ther , vol.9 , Issue.6 , pp. 719-728
    • Alric, P.1    Hinchliff, R.J.2    MacSweeney, S.T.3
  • 8
    • 0346347983 scopus 로고    scopus 로고
    • Endotension after endovascular repair: The Ancure experience
    • Meier GH, Parker FM, Godziachvili V, et al. Endotension after endovascular repair: the Ancure experience. J Vasc Surg. 2001;34:421-427.
    • (2001) J Vasc Surg , vol.34 , pp. 421-427
    • Meier, G.H.1    Parker, F.M.2    Godziachvili, V.3
  • 9
    • 33749441057 scopus 로고    scopus 로고
    • Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience. European Collaborators on Stent/graft techniques for aortic aneurysm repair
    • Harris PL, Vallabhaneni SR, Desgranges P, et al. Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience. European Collaborators on Stent/graft techniques for aortic aneurysm repair. J Vasc Surg. 2000;21:344-349.
    • (2000) J Vasc Surg , vol.21 , pp. 344-349
    • Harris, P.L.1    Vallabhaneni, S.R.2    Desgranges, P.3
  • 10
    • 0141649576 scopus 로고    scopus 로고
    • Endotension. A review of current views on pathophysiology and treatment
    • Dubenec SR, White GH, Pasenau J, et al. Endotension. A review of current views on pathophysiology and treatment. J Cardiovasc Surg (Torino). 2003;44(4):553-557.
    • (2003) J Cardiovasc Surg (Torino) , vol.44 , Issue.4 , pp. 553-557
    • Dubenec, S.R.1    White, G.H.2    Pasenau, J.3
  • 11
    • 0036328182 scopus 로고    scopus 로고
    • Imaging of aortic stent-grafts and endoleaks
    • Thurnher S, Cejna M. Imaging of aortic stent-grafts and endoleaks. Radiol Clin North Am. 2002;40:799-833.
    • (2002) Radiol Clin North Am , vol.40 , pp. 799-833
    • Thurnher, S.1    Cejna, M.2
  • 12
    • 20444485179 scopus 로고    scopus 로고
    • Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: A systematic review
    • Ashoke R, Brown LC, Rodway A, et al. Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: a systematic review. J Endovasc Ther. 2005(3):297-305.
    • (2005) J Endovasc Ther , Issue.3 , pp. 297-305
    • Ashoke, R.1    Brown, L.C.2    Rodway, A.3
  • 13
    • 3242672662 scopus 로고    scopus 로고
    • Blood flow patterns in focal liver lesions at microbubble-enhanced US
    • July-August
    • Brannigan M, Burns PN, Wilson SR. Blood flow patterns in focal liver lesions at microbubble-enhanced US. Radiographics. July-August 2004;24(4):921-935.
    • (2004) Radiographics , vol.24 , Issue.4 , pp. 921-935
    • Brannigan, M.1    Burns, P.N.2    Wilson, S.R.3
  • 14
    • 0036135989 scopus 로고    scopus 로고
    • Focal hepatic masses: Enhancement patterns with SHU 508A and pulse-inversion US
    • Dill-Macky MJ, Burns PN, Khalili K, et al. Focal hepatic masses: enhancement patterns with SHU 508A and pulse-inversion US. Radiology. 2002;222:95-102.
    • (2002) Radiology , vol.222 , pp. 95-102
    • Dill-Macky, M.J.1    Burns, P.N.2    Khalili, K.3
  • 15
    • 0034967707 scopus 로고    scopus 로고
    • Liver mass evaluation with ultrasound: The impact of microbubble contrast agents and pulse inversion imaging
    • May
    • Wilson SR, Burns PN. Liver mass evaluation with ultrasound: the impact of microbubble contrast agents and pulse inversion imaging. Semin Liver Dis. May 2001;21(2):147-159.
    • (2001) Semin Liver Dis , vol.21 , Issue.2 , pp. 147-159
    • Wilson, S.R.1    Burns, P.N.2
  • 16
    • 0042733074 scopus 로고    scopus 로고
    • Contrast enhanced ultrasound imaging for aortic stent-graft surveillance
    • April
    • Giannoni MF, Palombo G, Sbarigia E, et al. Contrast enhanced ultrasound imaging for aortic stent-graft surveillance. J Endovasc Ther. April 2003;10(2):208-217.
    • (2003) J Endovasc Ther , vol.10 , Issue.2 , pp. 208-217
    • Giannoni, M.F.1    Palombo, G.2    Sbarigia, E.3
  • 17
    • 0037329016 scopus 로고    scopus 로고
    • Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts
    • February
    • Bendick PJ, Bove PG, Long GW, et al. Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts. J Vasc Surg. February 2003;37(2):381-385.
    • (2003) J Vasc Surg , vol.37 , Issue.2 , pp. 381-385
    • Bendick, P.J.1    Bove, P.G.2    Long, G.W.3
  • 18
    • 0036263074 scopus 로고    scopus 로고
    • Detection of endoleak with enhanced ultrasound imaging: Comparison with biphasic computed tomography
    • April
    • McWilliams RG, Martin JM, White D, et al. Detection of endoleak with enhanced ultrasound imaging: comparison with biphasic computed tomography. J Endovasc Ther. April 2002;9(2):170-179.
    • (2002) J Endovasc Ther , vol.9 , Issue.2 , pp. 170-179
    • McWilliams, R.G.1    Martin, J.M.2    White, D.3
  • 19
    • 0032888365 scopus 로고    scopus 로고
    • Use of contrast-enhanced ultrasound in follow-up after endovascular aortic aneurysm repair
    • September
    • McWilliams RG, Martin JM, White D, et al. Use of contrast-enhanced ultrasound in follow-up after endovascular aortic aneurysm repair. J Vasc Interv Radiol. September 1999;10(8):1107-1114.
    • (1999) J Vasc Interv Radiol , vol.10 , Issue.8 , pp. 1107-1114
    • McWilliams, R.G.1    Martin, J.M.2    White, D.3
  • 20
    • 0037404191 scopus 로고    scopus 로고
    • Ultrasonographic detection of focal liver lesions: Increased sensitivity and specificity with microbubble contrast agents
    • May
    • Hohmann J, Albrecht T, Hoffmann CW, et al. Ultrasonographic detection of focal liver lesions: increased sensitivity and specificity with microbubble contrast agents. Eur J Radiol. May 2003;46(2):147-156.
    • (2003) Eur J Radiol , vol.46 , Issue.2 , pp. 147-156
    • Hohmann, J.1    Albrecht, T.2    Hoffmann, C.W.3
  • 21
    • 4644350819 scopus 로고    scopus 로고
    • Abdominal aortic aneurysm: Contrast-enhanced US for missed endoleaks after endoluminal repair
    • Napoli V, Bargellini I, Sardella SG, et al. Abdominal aortic aneurysm: contrast-enhanced US for missed endoleaks after endoluminal repair. Radiology. 2004;233:217-225.
    • (2004) Radiology , vol.233 , pp. 217-225
    • Napoli, V.1    Bargellini, I.2    Sardella, S.G.3
  • 22
    • 0242548488 scopus 로고    scopus 로고
    • Improved detection of hepatic metastases with pulse-inversion US during the liver-specific phase of SHU 508A: Multicenter study
    • May
    • Albrecht T, Blomley MJ, Burns PN, et al. Improved detection of hepatic metastases with pulse-inversion US during the liver-specific phase of SHU 508A: multicenter study. Radiology. May 2003;46(2):361-370.
    • (2003) Radiology , vol.46 , Issue.2 , pp. 361-370
    • Albrecht, T.1    Blomley, M.J.2    Burns, P.N.3
  • 23
    • 0037407663 scopus 로고    scopus 로고
    • Detection of endoleaks after endovascular repair of abdominal aortic aneurysm: Value of unenhanced and delayed helical CT acquisitions
    • May [e-pub April 03, 2003]
    • Rozenblit AM, Patlas M, Rosenbaum AT, et al. Detection of endoleaks after endovascular repair of abdominal aortic aneurysm: value of unenhanced and delayed helical CT acquisitions. Radiology. May 2003;227(2):426-433. [e-pub April 03, 2003].
    • (2003) Radiology , vol.227 , Issue.2 , pp. 426-433
    • Rozenblit, A.M.1    Patlas, M.2    Rosenbaum, A.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.