Volumn 207, Issue , 2006, Pages 735-742

Investigation of expansion characteristics of coronary slot stents using finite element analysis

Author keywords

Angioplasty; Expansion characteristics; Finite element analysis; Simulation stent

Indexed keywords

BLOOD VESSELS; HEART; MANUFACTURE; PRODUCT DESIGN; STENTS;

EID: 33749342103     PISSN: 15715736     EISSN: None     Source Type: Book Series    
DOI: 10.1007/0-387-34403-9_103     Document Type: Conference Paper
Times cited : (1)

References (11)
  • 2
    • 0001040614 scopus 로고    scopus 로고
    • Simulation of in vivo loading conditions of nitinol vascular stent structures
    • F. D. Whitcher, Simulation of in vivo loading conditions of nitinol vascular stent structures, Comp. & Struct. 64(5), 1005-1011 (1997).
    • (1997) Comp. & Struct. , vol.64 , Issue.5 , pp. 1005-1011
    • Whitcher, F.D.1
  • 3
    • 0034333737 scopus 로고    scopus 로고
    • Mechanical behaviour modelling of balloon-expandable stents
    • C. Dumoulin, and B. Cochelin, Mechanical behaviour modelling of balloon-expandable stents, J. Biomech. 33(11), 1461-1470 (2000).
    • (2000) J. Biomech. , vol.33 , Issue.11 , pp. 1461-1470
    • Dumoulin, C.1    Cochelin, B.2
  • 5
    • 0242608330 scopus 로고    scopus 로고
    • Finite element simulation of stent and balloon interaction
    • S. N. D. Chua, B. J. MacDonald and M. S. J. Hashmi, Finite element simulation of stent and balloon interaction, J. Mater. Process. Tech. 143-144, 591-597 (2003).
    • (2003) J. Mater. Process. Tech. , vol.143-144 , pp. 591-597
    • Chua, S.N.D.1    MacDonald, B.J.2    Hashmi, M.S.J.3
  • 6
    • 0029849690 scopus 로고    scopus 로고
    • Atheroma: More than mush
    • P. Libby, Atheroma: More than mush. Lancet. 348(Suppl. 1), s4-s7 (1996).
    • (1996) Lancet , vol.348 , Issue.SUPPL. 1
    • Libby, P.1
  • 8
    • 21144448039 scopus 로고    scopus 로고
    • Effects of stent structure on stent flexibility measurements
    • K. Mori and T. Saito, Effects of stent structure on stent flexibility measurements. Annals. Biomed. Eng. 33(6), 733-742 (2005).
    • (2005) Annals. Biomed. Eng. , vol.33 , Issue.6 , pp. 733-742
    • Mori, K.1    Saito, T.2
  • 9
    • 0033525544 scopus 로고    scopus 로고
    • Balloon-artery interactions during stent placement: A finite element analysis approach to pressure, compliance, and stent design as contributors to vascular injury
    • C. Rogers, D. Y. Tseng, J. C. Squire and E. R. Edelman, Balloon-artery interactions during stent placement: A finite element analysis approach to pressure, compliance, and stent design as contributors to vascular injury, Circ. Res. 84(4), 378-383 (1999).
    • (1999) Circ. Res. , vol.84 , Issue.4 , pp. 378-383
    • Rogers, C.1    Tseng, D.Y.2    Squire, J.C.3    Edelman, E.R.4
  • 11
    • 1642632674 scopus 로고    scopus 로고
    • Finite element modeling and intravascular ultrasound elastography of vulnerable plaques: Parameter variation
    • R. A. Baldewsing, C. L. de Korte, J. A. Schaar, F. Mastik and A. F. van der Steen, Finite element modeling and intravascular ultrasound elastography of vulnerable plaques: Parameter variation, Ultrasonics. 42(1-9), 723-729 (2004).
    • (2004) Ultrasonics. , vol.42 , Issue.1-9 , pp. 723-729
    • Baldewsing, R.A.1    de Korte, C.L.2    Schaar, J.A.3    Mastik, F.4    van der Steen, A.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.