메뉴 건너뛰기




Volumn 32, Issue 5, 2006, Pages 537-541

Duplex Ultrasound Scanning is Reliable in the Detection of Endoleak Following Endovascular Aneurysm Repair

Author keywords

Aneurysm; Endoleak; Endovascular; Follow up

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ANEURYSM SURGERY; ARTICLE; CONTRAST ENHANCEMENT; CONTROLLED STUDY; DIAGNOSTIC ERROR; DIAGNOSTIC IMAGING; DIAGNOSTIC VALUE; DOSIMETRY; ECHOGRAPHY; ENDOLEAK; ENDOVASCULAR SURGERY; FOLLOW UP; HEALTH CARE COST; HUMAN; INTERMETHOD COMPARISON; KAPPA STATISTICS; MAJOR CLINICAL STUDY; POSTOPERATIVE CARE; PREDICTION; PRIORITY JOURNAL; RELIABILITY; SENSITIVITY AND SPECIFICITY; SPIRAL COMPUTER ASSISTED TOMOGRAPHY;

EID: 33749319393     PISSN: 10785884     EISSN: 15322165     Source Type: Journal    
DOI: 10.1016/j.ejvs.2006.05.013     Document Type: Article
Times cited : (55)

References (18)
  • 1
    • 0026321992 scopus 로고
    • Transfemoral intraluminal graft implantation for abdominal aortic aneurysm
    • Parodi J.C., Palmaz J.C., and Barone H.D. Transfemoral intraluminal graft implantation for abdominal aortic aneurysm. Ann Vasc Surg 5 (1991) 491-497
    • (1991) Ann Vasc Surg , vol.5 , pp. 491-497
    • Parodi, J.C.1    Palmaz, J.C.2    Barone, H.D.3
  • 2
    • 84993746135 scopus 로고    scopus 로고
    • Endovascular aneurysm repair versus open repair in patients with abdominal aortic aneurysm (EVAR trial 1): randomised controlled trial
    • EVAR trial participants. Endovascular aneurysm repair versus open repair in patients with abdominal aortic aneurysm (EVAR trial 1): randomised controlled trial. Lancet 365 9478 (2005) 2179-2186
    • (2005) Lancet , vol.365 , Issue.9478 , pp. 2179-2186
    • EVAR trial participants1
  • 3
    • 0031647176 scopus 로고    scopus 로고
    • Type III and IV endoleak: toward a complete definition of blood flow in the sac after endoluminal AAA repair
    • White G.H., May J., Waugh R.C., Chaufour X., and Yu W. Type III and IV endoleak: toward a complete definition of blood flow in the sac after endoluminal AAA repair. J Endovasc Surg 5 4 (1998) 305-309
    • (1998) J Endovasc Surg , vol.5 , Issue.4 , pp. 305-309
    • White, G.H.1    May, J.2    Waugh, R.C.3    Chaufour, X.4    Yu, W.5
  • 4
    • 0031896189 scopus 로고    scopus 로고
    • Clinical consequences of periprosthetic leak after endovascular repair of abdominal aortic aneurysm. Endovascular Technologies Investigators
    • Matsumura J.S., and Moore W.S. Clinical consequences of periprosthetic leak after endovascular repair of abdominal aortic aneurysm. Endovascular Technologies Investigators. J Vasc Surg 27 (1998) 606-613
    • (1998) J Vasc Surg , vol.27 , pp. 606-613
    • Matsumura, J.S.1    Moore, W.S.2
  • 5
    • 0033782683 scopus 로고    scopus 로고
    • Incidence and risk factors of late rupture, conversion and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience
    • Harris P.L., Vallabhaneni S.R., Desgranges P., Becquemin J.-P., van Marrewijk C., and Laheij R.J.F. Incidence and risk factors of late rupture, conversion and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience. J Vasc Surg 32 (2000) 739-749
    • (2000) J Vasc Surg , vol.32 , pp. 739-749
    • Harris, P.L.1    Vallabhaneni, S.R.2    Desgranges, P.3    Becquemin, J.-P.4    van Marrewijk, C.5    Laheij, R.J.F.6
  • 6
    • 0033637752 scopus 로고    scopus 로고
    • Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repair
    • Wolf Y.G., Johnson B.L., Hill B.B., Rubin G.D., Fogarty T.J., and Zarins C.K. Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repair. J Vasc Surg 32 6 (2000) 1142-1148
    • (2000) J Vasc Surg , vol.32 , Issue.6 , pp. 1142-1148
    • Wolf, Y.G.1    Johnson, B.L.2    Hill, B.B.3    Rubin, G.D.4    Fogarty, T.J.5    Zarins, C.K.6
  • 7
    • 0031757739 scopus 로고    scopus 로고
    • Endoleak after aortic stent graft repair: diagnosis by color duplex ultrasound scan versus computed tomography scan
    • Sato D.T., Goff C.D., Gregory R.T., et al. Endoleak after aortic stent graft repair: diagnosis by color duplex ultrasound scan versus computed tomography scan. J Vasc Surg 28 4 (1998) 657-663
    • (1998) J Vasc Surg , vol.28 , Issue.4 , pp. 657-663
    • Sato, D.T.1    Goff, C.D.2    Gregory, R.T.3
  • 8
    • 2542436963 scopus 로고    scopus 로고
    • Computed tomography and ultrasound in follow-up of patients after endovascular repair of abdominal aortic aneurysm
    • Elkouri S., Panneton J.M., Andrews J.C., et al. Computed tomography and ultrasound in follow-up of patients after endovascular repair of abdominal aortic aneurysm. Ann Vasc Surg 18 3 (2004) 271-279
    • (2004) Ann Vasc Surg , vol.18 , Issue.3 , pp. 271-279
    • Elkouri, S.1    Panneton, J.M.2    Andrews, J.C.3
  • 9
    • 0141885385 scopus 로고    scopus 로고
    • Color-flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair
    • Raman K.G., Missig-Carroll N., Richardson T., Muluk S., and Makaroun M.S. Color-flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair. J Vasc Surg 38 4 (2003) 645-651
    • (2003) J Vasc Surg , vol.38 , Issue.4 , pp. 645-651
    • Raman, K.G.1    Missig-Carroll, N.2    Richardson, T.3    Muluk, S.4    Makaroun, M.S.5
  • 10
    • 0036263074 scopus 로고    scopus 로고
    • Detection of endoleak with enhanced ultrasound imaging: comparison with biphasic computed tomography
    • McWilliams R.G., Martin J., White D., et al. Detection of endoleak with enhanced ultrasound imaging: comparison with biphasic computed tomography. J Endovasc Ther 9 2 (2002) 170-179
    • (2002) J Endovasc Ther , vol.9 , Issue.2 , pp. 170-179
    • McWilliams, R.G.1    Martin, J.2    White, D.3
  • 11
    • 20444485179 scopus 로고    scopus 로고
    • Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: a systematic review
    • Ashoke R., Brown L.C., Rodway A., Choke E., Thompson M.M., Greenhalgh R.M., et al. Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: a systematic review. J Endovasc Ther 12 3 (2005) 297-305
    • (2005) J Endovasc Ther , vol.12 , Issue.3 , pp. 297-305
    • Ashoke, R.1    Brown, L.C.2    Rodway, A.3    Choke, E.4    Thompson, M.M.5    Greenhalgh, R.M.6
  • 12
    • 0036514934 scopus 로고    scopus 로고
    • Significance of endoleaks after endovascular repair of absominal aortic aneurysms: the EUROSTAR experience
    • van Marrewijk C., Buth J., Harris P.L., Norgren L., Nevelsteen A., and Wyatt M.G. Significance of endoleaks after endovascular repair of absominal aortic aneurysms: the EUROSTAR experience. J Vasc Surg 35 3 (2002) 461-473
    • (2002) J Vasc Surg , vol.35 , Issue.3 , pp. 461-473
    • van Marrewijk, C.1    Buth, J.2    Harris, P.L.3    Norgren, L.4    Nevelsteen, A.5    Wyatt, M.G.6
  • 13
    • 26944486193 scopus 로고    scopus 로고
    • Computed tomography versus color duplex ultrasound for surveillance of abdominal aortic stent-grafts
    • AbuRahma A.F., Welch C.A., Mullins B.B., and Dyer B. Computed tomography versus color duplex ultrasound for surveillance of abdominal aortic stent-grafts. J Endovasc Ther 12 5 (2005) 568-573
    • (2005) J Endovasc Ther , vol.12 , Issue.5 , pp. 568-573
    • AbuRahma, A.F.1    Welch, C.A.2    Mullins, B.B.3    Dyer, B.4
  • 14
    • 32344448367 scopus 로고    scopus 로고
    • Contrast -enhanced Duplex surveillance after endovascular abdominal aortic aneurysm repair: improved efficacy using a continuous infusion technique
    • Henao E.A., Hodge M., Felkai D.D., McCollum C.H., Noon G.P., Lin P.H., et al. Contrast -enhanced Duplex surveillance after endovascular abdominal aortic aneurysm repair: improved efficacy using a continuous infusion technique. J Vasc Surg 43 2 (2006) 259-264
    • (2006) J Vasc Surg , vol.43 , Issue.2 , pp. 259-264
    • Henao, E.A.1    Hodge, M.2    Felkai, D.D.3    McCollum, C.H.4    Noon, G.P.5    Lin, P.H.6
  • 16
    • 0033668254 scopus 로고    scopus 로고
    • Need for secondary interventions after endovascular repair of abdominal aortic aneurysms, Intermediate-term follow-up results of a European collaborative registry
    • on behalf of the EUROSTAR collaborators
    • Laheij R.J.F., Buth J., Harris P.L., Moll F.L., Stelter W.J., Verhoven E.L.G., and on behalf of the EUROSTAR collaborators. Need for secondary interventions after endovascular repair of abdominal aortic aneurysms, Intermediate-term follow-up results of a European collaborative registry. Br J Surg 87 12 (2000) 1666-1673
    • (2000) Br J Surg , vol.87 , Issue.12 , pp. 1666-1673
    • Laheij, R.J.F.1    Buth, J.2    Harris, P.L.3    Moll, F.L.4    Stelter, W.J.5    Verhoven, E.L.G.6
  • 17
    • 20344381834 scopus 로고    scopus 로고
    • Two-Year Outcomes after Conventional or Endovascular Repair of Abdominal Aortic Aneurysms
    • for the Dutch Randomised Endovascular Aneurysm Management (DREAM) Trial Group
    • Blankenstijn J.D., de Jong S.E.C.A., Prinssen M., van der Ham A., Buth J., van Sterkenburg S.M.M., et al., for the Dutch Randomised Endovascular Aneurysm Management (DREAM) Trial Group. Two-Year Outcomes after Conventional or Endovascular Repair of Abdominal Aortic Aneurysms. N Engl J Med 352 (2005) 2398-2405
    • (2005) N Engl J Med , vol.352 , pp. 2398-2405
    • Blankenstijn, J.D.1    de Jong, S.E.C.A.2    Prinssen, M.3    van der Ham, A.4    Buth, J.5    van Sterkenburg, S.M.M.6
  • 18
    • 21644445497 scopus 로고    scopus 로고
    • Cost effectiveness of endovascular abdominal aneurysm repair
    • Michaels J.A., Drury D., and Thomas S.M. Cost effectiveness of endovascular abdominal aneurysm repair. Br J Surg 92 8 (2005) 960-967
    • (2005) Br J Surg , vol.92 , Issue.8 , pp. 960-967
    • Michaels, J.A.1    Drury, D.2    Thomas, S.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.