메뉴 건너뛰기




Volumn 120, Issue 1, 2006, Pages 324-328

Angular displacement-enhanced heterodyne polarimeter for the measurement of optically active media

Author keywords

Angular displacement; Chiral medium; Glucose measurement; Heterodyne interferometer; Polarimeter

Indexed keywords

ANGLE MEASUREMENT; BLOOD; GLUCOSE; HETERODYNING; INTERFEROMETERS; OPTICAL SYSTEMS;

EID: 33749258915     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2006.02.023     Document Type: Article
Times cited : (15)

References (18)
  • 2
    • 0038758336 scopus 로고    scopus 로고
    • Addison-Wesley, Massachusetts (Chapter 8)
    • Hecht E. Optics (1998), Addison-Wesley, Massachusetts (Chapter 8)
    • (1998) Optics
    • Hecht, E.1
  • 3
    • 0020077396 scopus 로고
    • Noninvasive glucose monitoring of the aqueous humor of the eye. Part I. Measurement of very small optical rotation
    • Rabinovitch B., March W.F., and Adams R.L. Noninvasive glucose monitoring of the aqueous humor of the eye. Part I. Measurement of very small optical rotation. Diabetes Care 5 (1982) 254-258
    • (1982) Diabetes Care , vol.5 , pp. 254-258
    • Rabinovitch, B.1    March, W.F.2    Adams, R.L.3
  • 4
    • 0020055939 scopus 로고
    • Noninvasive glucose monitoring of the aqueous humor of the eye. Part II. Animal studies and the scleral lens
    • March W.F., Rabinovitch B., and Adams R.L. Noninvasive glucose monitoring of the aqueous humor of the eye. Part II. Animal studies and the scleral lens. Diabetes Care 5 (1982) 259-265
    • (1982) Diabetes Care , vol.5 , pp. 259-265
    • March, W.F.1    Rabinovitch, B.2    Adams, R.L.3
  • 5
    • 0000242875 scopus 로고    scopus 로고
    • Noninvasive glucose monitoring in vivo with optical heterodyne polarimeter
    • Chou C., Han C.Y., Kuo W.C., Huang Y.C., Feng C.M., and Shyu J.C. Noninvasive glucose monitoring in vivo with optical heterodyne polarimeter. Appl. Opt. 37 (1998) 3553-3557
    • (1998) Appl. Opt. , vol.37 , pp. 3553-3557
    • Chou, C.1    Han, C.Y.2    Kuo, W.C.3    Huang, Y.C.4    Feng, C.M.5    Shyu, J.C.6
  • 6
    • 0033624437 scopus 로고    scopus 로고
    • Optical glucose sensing in biological fluids: an overview
    • McNichols R.J., and Coté G.L. Optical glucose sensing in biological fluids: an overview. J. Biomed. Opt. 5 (2000) 5-16
    • (2000) J. Biomed. Opt. , vol.5 , pp. 5-16
    • McNichols, R.J.1    Coté, G.L.2
  • 7
    • 0031036953 scopus 로고    scopus 로고
    • Noninvasive blood glucose monitoring
    • Klonoff D.C. Noninvasive blood glucose monitoring. Diabetes Care 20 (1997) 433-437
    • (1997) Diabetes Care , vol.20 , pp. 433-437
    • Klonoff, D.C.1
  • 8
    • 0036629487 scopus 로고    scopus 로고
    • Effect of temperature, pH, and corneal birefringence on polarimetric glucose monitoring in the eye
    • Baba J.S., Cameron B.D., and Coté G.L. Effect of temperature, pH, and corneal birefringence on polarimetric glucose monitoring in the eye. J. Biomed. Opt. 7 (2002) 321-328
    • (2002) J. Biomed. Opt. , vol.7 , pp. 321-328
    • Baba, J.S.1    Cameron, B.D.2    Coté, G.L.3
  • 9
    • 0000093312 scopus 로고    scopus 로고
    • Precision synchronous polarimeter with linear response for the measurement of small rotation angles
    • Arnaud A., Silveira F., Frins E.M., Dubra A., Perciante C.D., and Ferrari J.A. Precision synchronous polarimeter with linear response for the measurement of small rotation angles. Appl. Opt. 39 (2000) 2601-2604
    • (2000) Appl. Opt. , vol.39 , pp. 2601-2604
    • Arnaud, A.1    Silveira, F.2    Frins, E.M.3    Dubra, A.4    Perciante, C.D.5    Ferrari, J.A.6
  • 10
    • 0031543269 scopus 로고    scopus 로고
    • Noninvasive glucose sensing utilizing a digital closed- loop polarimetric approach
    • Cameron B.D., and Coté G.L. Noninvasive glucose sensing utilizing a digital closed- loop polarimetric approach. IEEE Trans. Biomed. Eng. 44 (1997) 1221-1227
    • (1997) IEEE Trans. Biomed. Eng. , vol.44 , pp. 1221-1227
    • Cameron, B.D.1    Coté, G.L.2
  • 11
    • 0742270140 scopus 로고    scopus 로고
    • A compact polarimetric glucose sensor using a high-performance fibre-optic Faraday rotator
    • Yokota M., Sato Y., Yamaguchi I., Kenmochi T., and Yoshino T. A compact polarimetric glucose sensor using a high-performance fibre-optic Faraday rotator. Meas. Sci. Technol. 15 (2004) 143-147
    • (2004) Meas. Sci. Technol. , vol.15 , pp. 143-147
    • Yokota, M.1    Sato, Y.2    Yamaguchi, I.3    Kenmochi, T.4    Yoshino, T.5
  • 12
    • 0030703960 scopus 로고    scopus 로고
    • Amplitude sensitive optical heterodyne and phase lock-in technique on small optical rotation angle detection of chiral liquid
    • Chou C., Huang Y.C., Feng C.M., and Chang M. Amplitude sensitive optical heterodyne and phase lock-in technique on small optical rotation angle detection of chiral liquid. Jpn. J. Appl. Phys. 36 (1997) 356-359
    • (1997) Jpn. J. Appl. Phys. , vol.36 , pp. 356-359
    • Chou, C.1    Huang, Y.C.2    Feng, C.M.3    Chang, M.4
  • 13
    • 0026891886 scopus 로고
    • Noninvasive optical polarimetric glucose sensing using a true phase measurement technique
    • Coté G.L., Fox M.D., and Northrop R.B. Noninvasive optical polarimetric glucose sensing using a true phase measurement technique. IEEE Trans. Biomed. Eng. 39 (1992) 752-756
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , pp. 752-756
    • Coté, G.L.1    Fox, M.D.2    Northrop, R.B.3
  • 14
    • 0031165538 scopus 로고    scopus 로고
    • Precise optical activity measurement of quartz plate by using a true phase-sensitive technique
    • Chou C., Huang Y.C., and Chang M. Precise optical activity measurement of quartz plate by using a true phase-sensitive technique. Appl. Opt. 36 (1997) 3604-3609
    • (1997) Appl. Opt. , vol.36 , pp. 3604-3609
    • Chou, C.1    Huang, Y.C.2    Chang, M.3
  • 15
    • 0031233393 scopus 로고    scopus 로고
    • A true phase sensitive optical heterodyne polarimeter on glucose concentration measurement
    • Feng C.M., Huang Y.C., Chang J.G., Chang M., and Chou C. A true phase sensitive optical heterodyne polarimeter on glucose concentration measurement. Opt. Commun. 141 (1997) 314-321
    • (1997) Opt. Commun. , vol.141 , pp. 314-321
    • Feng, C.M.1    Huang, Y.C.2    Chang, J.G.3    Chang, M.4    Chou, C.5
  • 16
    • 3042852397 scopus 로고    scopus 로고
    • Improved method for measuring small optical rotation angle of chiral medium
    • Lin J.Y., Chen K.H., and Su D.C. Improved method for measuring small optical rotation angle of chiral medium. Opt. Commun. 238 (2004) 113-118
    • (2004) Opt. Commun. , vol.238 , pp. 113-118
    • Lin, J.Y.1    Chen, K.H.2    Su, D.C.3
  • 17
    • 4444252242 scopus 로고    scopus 로고
    • Roll angular displacement measurement system with microradian accuracy
    • Wu C.M., and Chuang Y.T. Roll angular displacement measurement system with microradian accuracy. Sens. Actuators A 116 (2004) 145-149
    • (2004) Sens. Actuators A , vol.116 , pp. 145-149
    • Wu, C.M.1    Chuang, Y.T.2
  • 18
    • 0037446422 scopus 로고    scopus 로고
    • Roll angle interferometer by means of wave plates
    • Liu Z., Lin D., Jiang H., and Yin C. Roll angle interferometer by means of wave plates. Sens. Actuators A 104 (2003) 127-131
    • (2003) Sens. Actuators A , vol.104 , pp. 127-131
    • Liu, Z.1    Lin, D.2    Jiang, H.3    Yin, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.