메뉴 건너뛰기




Volumn 29, Issue 8, 2006, Pages 750-755

A small scale oxygenator for cardiopulmonary bypass in rats

Author keywords

Artificial organ; Cardiopulmonary bypass; Heart; Lung; Oxygenation; Oxygenator blood; Rat

Indexed keywords

BLOOD; CYLINDERS (SHAPES); OXYGEN; OXYGENATORS; RATS; RESPIRATORY THERAPY;

EID: 33749256784     PISSN: 03913988     EISSN: None     Source Type: Journal    
DOI: 10.1177/039139880602900804     Document Type: Article
Times cited : (4)

References (21)
  • 3
    • 0028285208 scopus 로고
    • Oxygenator technology: The future
    • Voorhees ME. Oxygenator technology: The future. Perfusion 1994; 9: 229-32.
    • (1994) Perfusion , vol.9 , pp. 229-232
    • Voorhees, M.E.1
  • 4
    • 0030924958 scopus 로고    scopus 로고
    • Oxygenator anatomy and function
    • Wegner JA. Oxygenator anatomy and function. J Cardiothorac Vasc Anesth 1997; 11: 275-81.
    • (1997) J Cardiothorac Vasc Anesth , vol.11 , pp. 275-281
    • Wegner, J.A.1
  • 5
    • 0030911374 scopus 로고    scopus 로고
    • Perfusion safety: Past, present, and future
    • Palanzo DA. Perfusion safety: Past, present, and future. J Cardiothorac Vasc Anesth 1997; 11: 383-90.
    • (1997) J Cardiothorac Vasc Anesth , vol.11 , pp. 383-390
    • Palanzo, D.A.1
  • 7
    • 0037312501 scopus 로고    scopus 로고
    • Inflammatory response to cardiopulmonary bypass
    • Levy JH, Tanaka KA. Inflammatory response to cardiopulmonary bypass. Ann Thorac Surg 2003; 75 (suppl): S715-20.
    • (2003) Ann Thorac Surg , vol.75 , Issue.SUPPL.
    • Levy, J.H.1    Tanaka, K.A.2
  • 8
    • 0030296643 scopus 로고    scopus 로고
    • Partial cardiopulmonary bypass in rats for evaluating ischemia-reperfusion injury
    • Sasaki S, Takigami K, Shiiya N, Yasuda K. Partial cardiopulmonary bypass in rats for evaluating ischemia-reperfusion injury. ASAIO J 1996; 42: 1027-30.
    • (1996) ASAIO J , vol.42 , pp. 1027-1030
    • Sasaki, S.1    Takigami, K.2    Shiiya, N.3    Yasuda, K.4
  • 9
    • 78651036121 scopus 로고
    • Application of a mechanical heart and lung apparatus to cardiac surgery
    • Gibbon JH Jr. Application of a mechanical heart and lung apparatus to cardiac surgery. Minn Med 1954; 37: 171-85.
    • (1954) Minn Med , vol.37 , pp. 171-185
    • Gibbon Jr., J.H.1
  • 10
    • 0020524813 scopus 로고
    • Prolonged partial cardiopulmonary bypass in rats
    • Alexander B, Al Ani HR. Prolonged partial cardiopulmonary bypass in rats. J Surg Res 1983; 35: 28-34.
    • (1983) J Surg Res , vol.35 , pp. 28-34
    • Alexander, B.1    Al Ani, H.R.2
  • 11
    • 0014345350 scopus 로고
    • Effect of extracorporeal circulation on reticuloendothelial function. I. Experimental evidence for impaired reticuloendothelial function following cardiopulmonary bypass in rats
    • Subramanian V, McLeod J, Gans H. Effect of extracorporeal circulation on reticuloendothelial function. I. Experimental evidence for impaired reticuloendothelial function following cardiopulmonary bypass in rats. Surgery 1968; 64: 775-84.
    • (1968) Surgery , vol.64 , pp. 775-784
    • Subramanian, V.1    McLeod, J.2    Gans, H.3
  • 12
    • 0017365123 scopus 로고
    • An oxygenator for cardiopulmonary bypass in the rat
    • Proctor E. An oxygenator for cardiopulmonary bypass in the rat. J Surg Res 1977; 22: 124-7.
    • (1977) J Surg Res , vol.22 , pp. 124-127
    • Proctor, E.1
  • 14
    • 0014320357 scopus 로고
    • Hypothermic cardiopulmonary bypass in white rats
    • Popovic P, Horecky J, Popovic VP. Hypothermic cardiopulmonary bypass in white rats. Ann Surg 1968; 168: 298-301.
    • (1968) Ann Surg , vol.168 , pp. 298-301
    • Popovic, P.1    Horecky, J.2    Popovic, V.P.3
  • 15
    • 0016806686 scopus 로고
    • A comparison of membrane and bubble oxygenation as used in cardiopulmonary bypass in patients. The importance of pericardial blood as a source of hemolysis
    • Siderys H, Herod GT, Halbrook H, Pittman JN, Rubush JL, Kasebaker V, Berry GR Jr. A comparison of membrane and bubble oxygenation as used in cardiopulmonary bypass in patients. The importance of pericardial blood as a source of hemolysis. J Thorac Cardiovasc Surg 1975; 69: 708-12.
    • (1975) J Thorac Cardiovasc Surg , vol.69 , pp. 708-712
    • Siderys, H.1    Herod, G.T.2    Halbrook, H.3    Pittman, J.N.4    Rubush, J.L.5    Kasebaker, V.6    Berry Jr., G.R.7
  • 19
    • 0036245009 scopus 로고    scopus 로고
    • Early experience with a new technique and technology designed for the study of pulsatile cardiopulmonary bypass in the rat
    • Gourlay T, Ballaux PK, Draper ER, Taylor KM. Early experience with a new technique and technology designed for the study of pulsatile cardiopulmonary bypass in the rat. Perfusion 2002; 17: 191-8.
    • (2002) Perfusion , vol.17 , pp. 191-198
    • Gourlay, T.1    Ballaux, P.K.2    Draper, E.R.3    Taylor, K.M.4
  • 20
    • 14644438365 scopus 로고    scopus 로고
    • Rat cardiopulmonary bypass model: Application of a miniature extracorporeal circuit composed of asanguinous prime
    • You XM, Nasrallah F, Darling E, Robins M, Nieman G, Searles B. Rat cardiopulmonary bypass model: Application of a miniature extracorporeal circuit composed of asanguinous prime. J Extra Corpor Technol 2005; 37: 60-5.
    • (2005) J Extra Corpor Technol , vol.37 , pp. 60-65
    • You, X.M.1    Nasrallah, F.2    Darling, E.3    Robins, M.4    Nieman, G.5    Searles, B.6
  • 21
    • 33749253006 scopus 로고    scopus 로고
    • A simple device for invasive measurement of arterial blood pressure and ECG in the anesthesized rat
    • (in press)
    • Ordodi VL, Mic FA, Mic AA, Sandesc D, Paunescu V. A simple device for invasive measurement of arterial blood pressure and ECG in the anesthesized rat. Timisoara Medical Journal (in press).
    • Timisoara Medical Journal
    • Ordodi, V.L.1    Mic, F.A.2    Mic, A.A.3    Sandesc, D.4    Paunescu, V.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.