메뉴 건너뛰기




Volumn 5, Issue 3, 2006, Pages 147-156

Prostate irradiation in patients with hip prostheses - A retrospective analysis

Author keywords

Dosimetry; Heterogeneity; Hip; Prostate; Prosthesis; Total hip replacement

Indexed keywords

ARTICLE; BLADDER; CANCER RADIOTHERAPY; CANCER STAGING; CLINICAL ARTICLE; COMORBIDITY; DOSIMETRY; EXTERNAL BEAM RADIOTHERAPY; HIP PROSTHESIS; HUMAN; INTENSITY MODULATED RADIATION THERAPY; MALE; METAL IMPLANTATION; PROSTATE CANCER; RADIATION ATTENUATION; RADIATION DOSE; RADIATION ENERGY; RADIATION EXPOSURE; RECTUM; RETROSPECTIVE STUDY; RISK ASSESSMENT; TOTAL HIP PROSTHESIS; TREATMENT OUTCOME; TREATMENT PLANNING;

EID: 33749255948     PISSN: 14603969     EISSN: 14671131     Source Type: Journal    
DOI: 10.1017/S1460396906000203     Document Type: Article
Times cited : (1)

References (20)
  • 2
    • 4043048983 scopus 로고    scopus 로고
    • The effectiveness and cost effectiveness of different prostheses for primary total hip replacement
    • NICE Appraisal Group
    • NICE Appraisal Group, Taylor R. The effectiveness and cost effectiveness of different prostheses for primary total hip replacement. http://server2.nice.org.uk/embcat2.asp?page=oldsite/appraisals/hip_patie, 2000.
    • (2000)
    • Taylor, R.1
  • 4
    • 33749262962 scopus 로고    scopus 로고
    • Walker R. http://www.simetric.co.uk/si_metals.htm, 2006.
    • (2006)
    • Walker, R.1
  • 5
    • 10744226022 scopus 로고    scopus 로고
    • Dosimetric Considerations for patients with HIP prostheses undergoing pelvic irradiation
    • Report of the AAPM Radiation Therapy Committee Task Group 63
    • Reft C, Alecu R, Das I, et al. Dosimetric Considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63. Med Phys 2003; 30:1162-1182.
    • (2003) Med Phys , vol.30 , pp. 1162-1182
    • Reft, C.1    Alecu, R.2    Das, I.3
  • 6
    • 0034748597 scopus 로고    scopus 로고
    • Radical radiation therapy for carcinoma of the prostate in patients with a single hip prosthesis: A technique analysis using dose-volume histograms
    • Agapito J. Radical radiation therapy for carcinoma of the prostate in patients with a single hip prosthesis: A technique analysis using dose-volume histograms. Med Dosim 2001; 26:243-250.
    • (2001) Med Dosim , vol.26 , pp. 243-250
    • Agapito, J.1
  • 7
    • 0037833748 scopus 로고    scopus 로고
    • Image reconstruction and the effect on dose calculation for hip prostheses
    • Keall P, Chock L, Jeraj R, Siebers J, Mohan R. Image reconstruction and the effect on dose calculation for hip prostheses. Med Dosim 2003; 28:113-117.
    • (2003) Med Dosim , vol.28 , pp. 113-117
    • Keall, P.1    Chock, L.2    Jeraj, R.3    Siebers, J.4    Mohan, R.5
  • 10
    • 0035659744 scopus 로고    scopus 로고
    • Intensity-modulated radiotherapy for a patient with a metal prosthesis
    • Kung J, Reft C, Jackson W, Abdalla I. Intensity-modulated radiotherapy for a patient with a metal prosthesis. Med Dosim 2001; 26:305-308.
    • (2001) Med Dosim , vol.26 , pp. 305-308
    • Kung, J.1    Reft, C.2    Jackson, W.3    Abdalla, I.4
  • 13
    • 0023730965 scopus 로고
    • Hip prostheses during pelvic irradiation: Effects and corrections
    • Hazuka M, Ibbott G, Kinzie J. Hip prostheses during pelvic irradiation: effects and corrections. Int J Radiat Oncol Biol Phys 1988; 14:1311-1317.
    • (1988) Int J Radiat Oncol Biol Phys , vol.14 , pp. 1311-1317
    • Hazuka, M.1    Ibbott, G.2    Kinzie, J.3
  • 15
    • 0034125543 scopus 로고    scopus 로고
    • Dose attenuation through a titanium alloy hip prosthesis
    • Eng T. Dose attenuation through a titanium alloy hip prosthesis. Med Dosim 2000; 25:7-8.
    • (2000) Med Dosim , vol.25 , pp. 7-8
    • Eng, T.1
  • 16
    • 0030833379 scopus 로고    scopus 로고
    • Comparing 3-, 4- and 6- fields techniques for conformal irradiation of prostate and seminal vesicles using dose-volume histograms
    • Fiorino C, Reni M, Cattaneo G, Bolognesi A, Calandrino R. Comparing 3-, 4- and 6- fields techniques for conformal irradiation of prostate and seminal vesicles using dose-volume histograms. Radiother Oncol 1997; 44: 251-257.
    • (1997) Radiother Oncol , vol.44 , pp. 251-257
    • Fiorino, C.1    Reni, M.2    Cattaneo, G.3    Bolognesi, A.4    Calandrino, R.5
  • 18
    • 0033002774 scopus 로고    scopus 로고
    • Traditional and MLC based dose compensator design for patients with hip prostheses undergoing pelvic radiation therapy
    • Alecu R, Alecu M, Loomis T, Ochran T, He T. Traditional and MLC based dose compensator design for patients with hip prostheses undergoing pelvic radiation therapy. Med Dosim 1999; 24:33-37.
    • (1999) Med Dosim , vol.24 , pp. 33-37
    • Alecu, R.1    Alecu, M.2    Loomis, T.3    Ochran, T.4    He, T.5
  • 19
    • 0035889273 scopus 로고    scopus 로고
    • A study on beams passing through hip prosthesis for pelvic radiation treatment
    • Ding G, Yu C. A study on beams passing through hip prosthesis for pelvic radiation treatment. Int J Radiat Oncol Biol Phys 2001; 51:1167-1175.
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 1167-1175
    • Ding, G.1    Yu, C.2
  • 20
    • 0034826910 scopus 로고    scopus 로고
    • How accurate is a CT-based dose calculation on a pencil beam TPS for a patient with a metallic prosthesis?
    • Roberts R. How accurate is a CT-based dose calculation on a pencil beam TPS for a patient with a metallic prosthesis? Phys Med Biol 2001; 45:N227-N234.
    • (2001) Phys Med Biol , vol.45
    • Roberts, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.