메뉴 건너뛰기




Volumn 22, Issue 11, 2006, Pages 1051-1062

A comparison of three different methods for the quantification of the in vitro wear of dental materials

Author keywords

In vitro; Laser; Optical sensor; Profilometry; Wear; Wear simulator

Indexed keywords

LASERS; MEASUREMENT ERRORS; MERCURY AMALGAMS; OPTICAL SENSORS; PROFILOMETRY; STATISTICAL METHODS; WEAR OF MATERIALS;

EID: 33749254618     PISSN: 01095641     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.dental.2005.08.010     Document Type: Article
Times cited : (78)

References (30)
  • 1
    • 0036614935 scopus 로고    scopus 로고
    • Predictors of signs and symptoms of temporomandibular disorders: a 20-year follow-up study from childhood to adulthood
    • Carlsson G.E., Egermark I., and Magnusson T. Predictors of signs and symptoms of temporomandibular disorders: a 20-year follow-up study from childhood to adulthood. Acta Odontol Scand 60 (2002) 180-185
    • (2002) Acta Odontol Scand , vol.60 , pp. 180-185
    • Carlsson, G.E.1    Egermark, I.2    Magnusson, T.3
  • 2
    • 0036483797 scopus 로고    scopus 로고
    • No association between incisal tooth wear and temporomandibular disorders
    • John M.T., Frank H., Lobbezoo F., Drangsholt M., and Dette K.E. No association between incisal tooth wear and temporomandibular disorders. J Prosthet Dent 87 (2002) 197-203
    • (2002) J Prosthet Dent , vol.87 , pp. 197-203
    • John, M.T.1    Frank, H.2    Lobbezoo, F.3    Drangsholt, M.4    Dette, K.E.5
  • 3
    • 0024095298 scopus 로고
    • The prevalence of dental attrition and its association with factors of age, gender, occlusion, and TMJ symptomatology
    • Seligman D.A., Pullinger A.G., and Solberg W.K. The prevalence of dental attrition and its association with factors of age, gender, occlusion, and TMJ symptomatology. J Dent Res 67 (1988) 1323-1333
    • (1988) J Dent Res , vol.67 , pp. 1323-1333
    • Seligman, D.A.1    Pullinger, A.G.2    Solberg, W.K.3
  • 4
    • 0026919893 scopus 로고
    • Dental composites/glass ionomers: clinical reports
    • Bayne S.C. Dental composites/glass ionomers: clinical reports. Adv Dent Res 6 (1992) 65-77
    • (1992) Adv Dent Res , vol.6 , pp. 65-77
    • Bayne, S.C.1
  • 5
    • 33749265237 scopus 로고    scopus 로고
    • ISO. Dental materials, Guidance on testing of wear. Part 2. Wear by two-and/or three-body contact. Technical Specification 2001;No. 14569-2.
  • 6
    • 17844391022 scopus 로고    scopus 로고
    • Wear of ten dental restorative materials in five wear simulators-results of a round robin test
    • Heintze S.D., Zappini G., and Rousson V. Wear of ten dental restorative materials in five wear simulators-results of a round robin test. Dent Mater 21 (2005) 304-317
    • (2005) Dent Mater , vol.21 , pp. 304-317
    • Heintze, S.D.1    Zappini, G.2    Rousson, V.3
  • 7
    • 0028313363 scopus 로고    scopus 로고
    • Krejci I, Reich T, Bucher W, Lutz F. Eine neue Methode für die dreidimensionale Verschleissmessung. Schweiz Monatsschr Zahnmed 1994; 104:160-169.
  • 9
    • 0017951865 scopus 로고    scopus 로고
    • Mettler P, Friedrich U, Roulet JF. Studie über die Abrasion von Amalgam und Komposits im Seitenzahnbereich. SSO Schweiz Monatsschr Zahnheilkd 1978; 88:324-44.
  • 10
    • 33749257953 scopus 로고    scopus 로고
    • Roulet J-F, Reich T, Lutz F. High precision occlusal mapping-a new method for measuring wear of posterior composites. J Dent Res 1983; 62:220 [Abstract 457].
  • 12
    • 33749266454 scopus 로고
    • Messfehler bei der 3D-Erfassung von Oberflächen durch mechanische Profilometrie
    • Pelka M., Krämer N., and Kunzelmann K.H. Messfehler bei der 3D-Erfassung von Oberflächen durch mechanische Profilometrie. Dtsch Zahnärztl Z 50 (1995) 725-728
    • (1995) Dtsch Zahnärztl Z , vol.50 , pp. 725-728
    • Pelka, M.1    Krämer, N.2    Kunzelmann, K.H.3
  • 13
    • 0022020983 scopus 로고
    • Measurement of change in surface contour by computer graphics
    • DeLong R., Pintado M., and Douglas W.H. Measurement of change in surface contour by computer graphics. Dent Mater 1 (1985) 27-30
    • (1985) Dent Mater , vol.1 , pp. 27-30
    • DeLong, R.1    Pintado, M.2    Douglas, W.H.3
  • 14
    • 33749241990 scopus 로고    scopus 로고
    • Christensen R, Bangerter V. Apparatus for automated, non-contact measurements of surface changes. J Dent Res 1990; 69:126 [Abstract 140].
  • 16
    • 0031278678 scopus 로고    scopus 로고
    • A new optical 3D device for the detection of wear
    • Mehl A., Gloger W., Kunzelmann K.H., and Hickel R. A new optical 3D device for the detection of wear. J Dent Res 76 (1997) 1799-1807
    • (1997) J Dent Res , vol.76 , pp. 1799-1807
    • Mehl, A.1    Gloger, W.2    Kunzelmann, K.H.3    Hickel, R.4
  • 18
    • 33749249851 scopus 로고    scopus 로고
    • Willytec. Instructions of use Match 3D. 2001.
  • 19
    • 0042205403 scopus 로고    scopus 로고
    • Ein neues Verfahren für schnelle, präzise und reproduzierbare Messungen von Füllstoffdispersionen in Gummi
    • Kelbch S., Heinz M., and Koglin J. Ein neues Verfahren für schnelle, präzise und reproduzierbare Messungen von Füllstoffdispersionen in Gummi. KGK Kautschuk Gummi Kunststoffe 56 (2003) 381-387
    • (2003) KGK Kautschuk Gummi Kunststoffe , vol.56 , pp. 381-387
    • Kelbch, S.1    Heinz, M.2    Koglin, J.3
  • 20
    • 22144459824 scopus 로고    scopus 로고
    • Automatic gap detection at restoration margins with an optical sensor in vitro
    • Heintze S.D., Cavalleri A., and Rousson V. Automatic gap detection at restoration margins with an optical sensor in vitro. J Adhes Dent 7 (2005) 95-105
    • (2005) J Adhes Dent , vol.7 , pp. 95-105
    • Heintze, S.D.1    Cavalleri, A.2    Rousson, V.3
  • 21
    • 33749236181 scopus 로고    scopus 로고
    • DIN. Längenprüftechnik 1 Grundnormen. Berlin: Beuth, 2000.
  • 22
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 23
    • 0042362216 scopus 로고    scopus 로고
    • Confidence intervals for intraclass correlation in inter-rater reliability
    • Rousson V., Gasser T., and Seifert B. Confidence intervals for intraclass correlation in inter-rater reliability. Scand J Statistics 30 (2003) 617-624
    • (2003) Scand J Statistics , vol.30 , pp. 617-624
    • Rousson, V.1    Gasser, T.2    Seifert, B.3
  • 24
    • 0036052629 scopus 로고    scopus 로고
    • Replica of human dentin treated with different desensitizing agents: a methodological SEM study in vitro
    • Pereira J.C., Martineli A.C., and Tung M.S. Replica of human dentin treated with different desensitizing agents: a methodological SEM study in vitro. Braz Dent J 13 (2002) 75-85
    • (2002) Braz Dent J , vol.13 , pp. 75-85
    • Pereira, J.C.1    Martineli, A.C.2    Tung, M.S.3
  • 25
    • 0026220390 scopus 로고
    • In vitro and in vivo replication for scanning electron microscopy of the cervical region of human teeth
    • discussion 739-740
    • Bevenius J., and Hultenby K. In vitro and in vivo replication for scanning electron microscopy of the cervical region of human teeth. Scanning Microsc 5 (1991) 731-739 discussion 739-740
    • (1991) Scanning Microsc , vol.5 , pp. 731-739
    • Bevenius, J.1    Hultenby, K.2
  • 26
    • 0019617544 scopus 로고
    • An universal and accurate replica technique for scanning electron microscope study in clinical dentistry
    • Lambrechts P., Vanherle G., and Davidson C. An universal and accurate replica technique for scanning electron microscope study in clinical dentistry. Microsc Acta 85 (1981) 45-58
    • (1981) Microsc Acta , vol.85 , pp. 45-58
    • Lambrechts, P.1    Vanherle, G.2    Davidson, C.3
  • 27
    • 0035514703 scopus 로고    scopus 로고
    • Fit of implant-supported fixed prostheses fabricated on master casts made from a dental stone and a dental plaster
    • Wise M. Fit of implant-supported fixed prostheses fabricated on master casts made from a dental stone and a dental plaster. J Prosthet Dent 86 (2001) 532-538
    • (2001) J Prosthet Dent , vol.86 , pp. 532-538
    • Wise, M.1
  • 28
    • 0020037919 scopus 로고
    • A new in vivo replica technique for scanning electron microscope study of dental plaque morphology
    • Lambrechts P., van Steenberghe D., and Vanherle G. A new in vivo replica technique for scanning electron microscope study of dental plaque morphology. J Clin Periodontol 9 (1982) 252-256
    • (1982) J Clin Periodontol , vol.9 , pp. 252-256
    • Lambrechts, P.1    van Steenberghe, D.2    Vanherle, G.3
  • 29
    • 26444546802 scopus 로고    scopus 로고
    • Roughness of different dental materials before and after simulated toothbrushing in vitro
    • Heintze S.D., and Forjanic M. Roughness of different dental materials before and after simulated toothbrushing in vitro. Oper Dent 30 (2005) 617-626
    • (2005) Oper Dent , vol.30 , pp. 617-626
    • Heintze, S.D.1    Forjanic, M.2
  • 30
    • 0026444619 scopus 로고
    • Accuracy testing of 3D digitizing systems
    • Hewlett E.R., Orro M.E., and Clark G.T. Accuracy testing of 3D digitizing systems. Dent Mater 8 (1992) 49-53
    • (1992) Dent Mater , vol.8 , pp. 49-53
    • Hewlett, E.R.1    Orro, M.E.2    Clark, G.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.