메뉴 건너뛰기




Volumn 79, Issue 1, 2006, Pages 16-24

Pin-on-disc evaluation of self-reinforced composite poly(methyl methacrylate) for total joint replacements

Author keywords

Acrylic; Bone cement; Hip prosthesis; PMMA; Wear; Wear debris

Indexed keywords

SELF-REINFORCED COMPOSITES; WEAR DEBRIS; WEAR PARTICLES;

EID: 33749164433     PISSN: 00219304     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.30506     Document Type: Article
Times cited : (10)

References (41)
  • 1
    • 0016748179 scopus 로고
    • Fracture of femoral prostheses in total hip replacement
    • Charnley J. Fracture of femoral prostheses in total hip replacement. Clin Orthop 1975;111:105-120.
    • (1975) Clin Orthop , vol.111 , pp. 105-120
    • Charnley, J.1
  • 2
    • 0028243001 scopus 로고
    • Theories of wear and loosening in hip prostheses: Wear-induced loosening vs loosening-induced wear-A review
    • Mjöberg B. Theories of wear and loosening in hip prostheses: Wear-induced loosening vs loosening-induced wear-A review. Acta Orthop Scand 1994;65:361-371.
    • (1994) Acta Orthop Scand , vol.65 , pp. 361-371
    • Mjöberg, B.1
  • 3
    • 0035215251 scopus 로고    scopus 로고
    • Charnley total hip arthroplasty with use of improved cementing techniques: A minimum twenty-year follow-up study
    • Klapach AS, Callaghan JJ, Goetz DD, Olejniczak JP, Johnston RC. Charnley total hip arthroplasty with use of improved cementing techniques: A minimum twenty-year follow-up study. J Bone Joint Surg Am 2001;83:1840-1848.
    • (2001) J Bone Joint Surg Am , vol.83 , pp. 1840-1848
    • Klapach, A.S.1    Callaghan, J.J.2    Goetz, D.D.3    Olejniczak, J.P.4    Johnston, R.C.5
  • 5
    • 0031837235 scopus 로고    scopus 로고
    • Charnley total hip arthroplasty in patients less than fifty years old. A twenty to twenty-five-year follow-up note
    • Callaghan JJ, Forest EE, Olejniczak JP, Goetz DD, Johnston RC. Charnley total hip arthroplasty in patients less than fifty years old. A twenty to twenty-five-year follow-up note. J Bone Joint Surg Am 1998;80:704-714.
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 704-714
    • Callaghan, J.J.1    Forest, E.E.2    Olejniczak, J.P.3    Goetz, D.D.4    Johnston, R.C.5
  • 7
    • 0025254587 scopus 로고
    • Osteolysis in alloarthroplasty of the hip: The role of bone cement fragmentation
    • Willert H-G, Bertram H, Buchhorn GH. Osteolysis in alloarthroplasty of the hip: The role of bone cement fragmentation. Clin Orthop 1990;258:108-120.
    • (1990) Clin Orthop , vol.258 , pp. 108-120
    • Willert, H.-G.1    Bertram, H.2    Buchhorn, G.H.3
  • 8
    • 0025388865 scopus 로고
    • A fractographic analysis of in vivo poly(methyl methacrylate) bone cement failure mechanisms
    • Topoleski LDT, Ducheyne P, Cuckler JM. A fractographic analysis of in vivo poly(methyl methacrylate) bone cement failure mechanisms. J Biomed Mater Res 1990;24:135-154.
    • (1990) J Biomed Mater Res , vol.24 , pp. 135-154
    • Topoleski, L.D.T.1    Ducheyne, P.2    Cuckler, J.M.3
  • 9
    • 0034040792 scopus 로고    scopus 로고
    • Effects of fatigue loading and PMMA precoating on the adhesion and subcritical debonding of prosthetic-PMMA interfaces
    • Ohashi KL, Dauskardt RH. Effects of fatigue loading and PMMA precoating on the adhesion and subcritical debonding of prosthetic-PMMA interfaces. J Biomed Mater Res 2000;51:172-183.
    • (2000) J Biomed Mater Res , vol.51 , pp. 172-183
    • Ohashi, K.L.1    Dauskardt, R.H.2
  • 10
    • 0036312327 scopus 로고    scopus 로고
    • Fatigue crack growth rate does not depend on mantle thickness: An idealized cemented stem construct under torsional loading
    • Hertzler J, Miller MA, Mann KA. Fatigue crack growth rate does not depend on mantle thickness: An idealized cemented stem construct under torsional loading. J Orthop Res 2002;20:676-682.
    • (2002) J Orthop Res , vol.20 , pp. 676-682
    • Hertzler, J.1    Miller, M.A.2    Mann, K.A.3
  • 11
    • 0023719883 scopus 로고
    • The effects of bulk versus particulate poly(methylmethacrylate) on bone
    • Goodman SB, Fornasier VL, Kei J. The effects of bulk versus particulate poly(methylmethacrylate) on bone. Clin Orthop 1988;232:255-262.
    • (1988) Clin Orthop , vol.232 , pp. 255-262
    • Goodman, S.B.1    Fornasier, V.L.2    Kei, J.3
  • 12
    • 0027535641 scopus 로고
    • Extensive porosity at the cement-femoral prosthesis interface: A preliminary study
    • James SP, Schmalzried TP, McGarry FJ, Harris WH. Extensive porosity at the cement-femoral prosthesis interface: A preliminary study. J Biomed Mater Res 1993;27:71-78.
    • (1993) J Biomed Mater Res , vol.27 , pp. 71-78
    • James, S.P.1    Schmalzried, T.P.2    McGarry, F.J.3    Harris, W.H.4
  • 13
    • 0033749234 scopus 로고    scopus 로고
    • The significance of stem-cement loosening of grit-blasted femoral components
    • Schmalzried TP, Zahiri CA, Woolson ST. The significance of stem-cement loosening of grit-blasted femoral components. Orthopedics 2000;23:1157-1164.
    • (2000) Orthopedics , vol.23 , pp. 1157-1164
    • Schmalzried, T.P.1    Zahiri, C.A.2    Woolson, S.T.3
  • 14
    • 0031762032 scopus 로고    scopus 로고
    • Effects of design changes on cemented tapered femoral stem fixation
    • Middleton RG, Howie DW, Costi K, Sharpe P. Effects of design changes on cemented tapered femoral stem fixation. Clin Orthop 1998;355:47-56.
    • (1998) Clin Orthop , vol.355 , pp. 47-56
    • Middleton, R.G.1    Howie, D.W.2    Costi, K.3    Sharpe, P.4
  • 15
    • 0032192224 scopus 로고    scopus 로고
    • Surface roughness of debonded straight-tapered stems in cemented THA reduces subsidence but not cement damage
    • Verdonschot N, Huiskes R. Surface roughness of debonded straight-tapered stems in cemented THA reduces subsidence but not cement damage. Biomatererials 1998;19:1773-1779.
    • (1998) Biomatererials , vol.19 , pp. 1773-1779
    • Verdonschot, N.1    Huiskes, R.2
  • 17
    • 0020176824 scopus 로고
    • Thin film PMMA precoating for improved implant bone-cement fixation
    • Raab S, Ahmed AM, Provan JW. Thin film PMMA precoating for improved implant bone-cement fixation. J Biomed Mater Res 1982;16:679-704.
    • (1982) J Biomed Mater Res , vol.16 , pp. 679-704
    • Raab, S.1    Ahmed, A.M.2    Provan, J.W.3
  • 19
    • 0033009808 scopus 로고    scopus 로고
    • Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement
    • Clohisy JC, Harris WH. Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement. J Bone Joint Surg Am 1999;81:247-255.
    • (1999) J Bone Joint Surg Am , vol.81 , pp. 247-255
    • Clohisy, J.C.1    Harris, W.H.2
  • 20
    • 0036562948 scopus 로고    scopus 로고
    • Early failure of precoated femoral components in primary total hip arthroplasty
    • Ong A, Wong KL, Lai M, Garino JP, Steinberg ME. Early failure of precoated femoral components in primary total hip arthroplasty. J Bone Joint Surg Am 2002;84:786-792.
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 786-792
    • Ong, A.1    Wong, K.L.2    Lai, M.3    Garino, J.P.4    Steinberg, M.E.5
  • 21
    • 0031762034 scopus 로고    scopus 로고
    • Failure of total hip arthroplasty with a precoated prosthesis: 4- to 11-year results
    • Dowd JE, Cha CW, Trakru S, Kim S-Y, Yang I-H, Rubash HE. Failure of total hip arthroplasty with a precoated prosthesis: 4- to 11-year results. Clin Orthop 1998;355:123-136.
    • (1998) Clin Orthop , vol.355 , pp. 123-136
    • Dowd, J.E.1    Cha, C.W.2    Trakru, S.3    Kim, S.-Y.4    Yang, I.-H.5    Rubash, H.E.6
  • 23
    • 0029165299 scopus 로고
    • Self-reinforced composite poly(methyl methacrylate): Static and fatigue properties
    • Gilbert JL, Ney DS, Lautenschlager EP. Self-reinforced composite poly(methyl methacrylate): Static and fatigue properties. Biomaterials 1995;16:1043-1055.
    • (1995) Biomaterials , vol.16 , pp. 1043-1055
    • Gilbert, J.L.1    Ney, D.S.2    Lautenschlager, E.P.3
  • 24
    • 0032778325 scopus 로고    scopus 로고
    • The effect of processing temperature and time on the structure and fracture characteristics of self-reinforced composite poly(methyl methacrylate)
    • Wright DD, Lautenschlager EP, Gilbert JL. The effect of processing temperature and time on the structure and fracture characteristics of self-reinforced composite poly(methyl methacrylate). J Mater Sci: Mater Med 1999;10:503-512.
    • (1999) J Mater Sci: Mater Med , vol.10 , pp. 503-512
    • Wright, D.D.1    Lautenschlager, E.P.2    Gilbert, J.L.3
  • 25
    • 0032102957 scopus 로고    scopus 로고
    • Interfacial properties of self-reinforced composite poly(methyl methacrylate)
    • Wright DD, Lautenschlager EP, Gilbert JL. Interfacial properties of self-reinforced composite poly(methyl methacrylate). J Biomed Mater Res 1998;43:153-161.
    • (1998) J Biomed Mater Res , vol.43 , pp. 153-161
    • Wright, D.D.1    Lautenschlager, E.P.2    Gilbert, J.L.3
  • 26
    • 0036206983 scopus 로고    scopus 로고
    • The effect of processing conditions on the properties of poly(methyl methacrylate) fibers
    • Wright DD, Lautenschlager EP, Gilbert JL. The effect of processing conditions on the properties of poly(methyl methacrylate) fibers. J Biomed Mater Res 2002;63:152-160.
    • (2002) J Biomed Mater Res , vol.63 , pp. 152-160
    • Wright, D.D.1    Lautenschlager, E.P.2    Gilbert, J.L.3
  • 27
    • 0009651582 scopus 로고    scopus 로고
    • Bending and fracture toughness of woven self-reinforced composite poly(methyl methacrylate)
    • Wright DD, Lautenschlager EP, Gilbert JL. Bending and fracture toughness of woven self-reinforced composite poly(methyl methacrylate). J Biomed Mater Res 1997;36:441-453.
    • (1997) J Biomed Mater Res , vol.36 , pp. 441-453
    • Wright, D.D.1    Lautenschlager, E.P.2    Gilbert, J.L.3
  • 31
    • 0020826227 scopus 로고
    • Cement strain measurement surrounding loose and well-fixed femoral compenent stems
    • Crowninshield RD, Tolbert JR. Cement strain measurement surrounding loose and well-fixed femoral compenent stems. J Biomed Mater Res 1983;17:819-828.
    • (1983) J Biomed Mater Res , vol.17 , pp. 819-828
    • Crowninshield, R.D.1    Tolbert, J.R.2
  • 33
    • 0031099919 scopus 로고    scopus 로고
    • Dry sliding friction and wear of short carbon-fiber-reinforced polyetheretherketone (PEEK) at elevated temperatures
    • Hanchi J, Eiss NSJ. Dry sliding friction and wear of short carbon-fiber-reinforced polyetheretherketone (PEEK) at elevated temperatures. Wear 1997;203/204:380-386.
    • (1997) Wear , vol.203-204 , pp. 380-386
    • Hanchi, J.1    Eiss, N.S.J.2
  • 34
    • 0033237671 scopus 로고    scopus 로고
    • Tribological behaviour of drawn polypropylene
    • Bekhet NE. Tribological behaviour of drawn polypropylene. Wear 1999;236:55-61.
    • (1999) Wear , vol.236 , pp. 55-61
    • Bekhet, N.E.1
  • 35
    • 0028349883 scopus 로고
    • Size and shape of biomaterial wear debris
    • Saviq JAI, Overcamp LM, Black J. Size and shape of biomaterial wear debris. Clin Mater 1994;15:101-147.
    • (1994) Clin Mater , vol.15 , pp. 101-147
    • Saviq, J.A.I.1    Overcamp, L.M.2    Black, J.3
  • 37
    • 0032773373 scopus 로고    scopus 로고
    • Effect of protein lubrication on the wear properties of materials for prosthetic joints
    • Liao YS, Benya PD, McKellop HA. Effect of protein lubrication on the wear properties of materials for prosthetic joints. J Biomed Mater Res 1999;48:465-473.
    • (1999) J Biomed Mater Res , vol.48 , pp. 465-473
    • Liao, Y.S.1    Benya, P.D.2    McKellop, H.A.3
  • 38
    • 23744442073 scopus 로고    scopus 로고
    • Nanomechanical properties of self-reinforced composite poly(methyl methacrylate) as a function of processing temperature
    • Wright-Charlesworth DD, Peers WJ, Miskioglu I, Loo LL. Nanomechanical properties of self-reinforced composite poly(methyl methacrylate) as a function of processing temperature. J Biomed Mater Res 2005;74:306-314.
    • (2005) J Biomed Mater Res , vol.74 , pp. 306-314
    • Wright-Charlesworth, D.D.1    Peers, W.J.2    Miskioglu, I.3    Loo, L.L.4
  • 39
    • 0018445898 scopus 로고
    • Effect of fiber orientation on friction and wear of fiber reinforced polymeric composites
    • Sung NH, Suh NP. Effect of fiber orientation on friction and wear of fiber reinforced polymeric composites. Wear 1979;53:129-141.
    • (1979) Wear , vol.53 , pp. 129-141
    • Sung, N.H.1    Suh, N.P.2
  • 40
    • 0017519189 scopus 로고
    • Overview of the delamination theory of wear
    • Suh NP. Overview of the delamination theory of wear. Wear 1977;44:1-16.
    • (1977) Wear , vol.44 , pp. 1-16
    • Suh, N.P.1
  • 41
    • 0030130840 scopus 로고    scopus 로고
    • Effect of size, concentration, surface area, and volume of poly(methylmethacrylate) particles on human macrophages in vitro
    • González O, Smith RL, Goodman SB. Effect of size, concentration, surface area, and volume of poly(methylmethacrylate) particles on human macrophages in vitro. J Biomed Mater Res 1996;30:463-473.
    • (1996) J Biomed Mater Res , vol.30 , pp. 463-473
    • González, O.1    Smith, R.L.2    Goodman, S.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.