메뉴 건너뛰기




Volumn , Issue , 2005, Pages 1942-1948

On-line monitoring of insulation aging in AC motors fed by PWM inverters

Author keywords

[No Author keywords available]

Indexed keywords

CAPACITANCE; CONDITION MONITORING; DIELECTRIC PROPERTIES; ELECTRIC BREAKDOWN; ELECTRIC INSULATION; ELECTRIC INVERTERS; PULSE WIDTH MODULATION; STATORS;

EID: 33749060043     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/iemdc.2005.195985     Document Type: Conference Paper
Times cited : (11)

References (11)
  • 1
    • 0031233739 scopus 로고    scopus 로고
    • Will your motor insulation survive a new adjustable frequency drive?
    • September/October
    • S.Bell, J.Sung, "Will your motor insulation survive a new adjustable frequency drive?, IEEE Transactions on Industry Applications, vol.33, No.5, September/October 1997, pp. 1307-1311.
    • (1997) IEEE Transactions on Industry Applications , vol.33 , Issue.5 , pp. 1307-1311
    • Bell, S.1    Sung, J.2
  • 2
    • 0028543269 scopus 로고
    • Motor failures due to steep fronted switching surges: The need for surge protection-user's experience
    • November/December
    • P.Zotos, "Motor failures due to Steep Fronted Switching Surges: The Need for Surge Protection-User's Experience," IEEE Transactions on Industry Applications, Vol.30, No.6, November/December 1994, pp. 1514-1524.
    • (1994) IEEE Transactions on Industry Applications , vol.30 , Issue.6 , pp. 1514-1524
    • Zotos, P.1
  • 4
    • 3142655686 scopus 로고    scopus 로고
    • Relation between space charge accumulation and partial discharge activity in enameled wires under PWM-like voltage waveforms
    • June
    • D. Fabiani, G.C. Montanari, A. Cavallini, O. Mazzanti, "Relation between space charge accumulation and partial discharge activity in enameled wires under PWM-like voltage waveforms," IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 11, No. 3, June 2004, pp. 393-405.
    • (2004) IEEE Transactions on Dielectrics and Electrical Insulation , vol.11 , Issue.3 , pp. 393-405
    • Fabiani, D.1    Montanari, G.C.2    Cavallini, A.3    Mazzanti, O.4
  • 10
    • 33644550234 scopus 로고    scopus 로고
    • AC motor magnetic signature: Contribution of stator laminations
    • Maribor, Slovenie, 18-20 September
    • D. Roger, A. Henneton, "AC motor magnetic signature: contribution of stator laminations," Conference ISEF 2003, Maribor, Slovenie, 18-20 September 2003, Vol. 1, pp. 421 - 426.
    • (2003) Conference ISEF 2003 , vol.1 , pp. 421-426
    • Roger, D.1    Henneton, A.2
  • 11
    • 0030107454 scopus 로고    scopus 로고
    • Calculation of machine winding electrical parameters at high frequencies for switching transient studies
    • March
    • J.L. Guardado, K.J. Komick, "Calculation of Machine Winding Electrical Parameters at High Frequencies for Switching Transient Studies," IEEE Transactions on Energy Conversion, Vol. 11, No 1, March 1996, pp. 33 - 40.
    • (1996) IEEE Transactions on Energy Conversion , vol.11 , Issue.1 , pp. 33-40
    • Guardado, J.L.1    Komick, K.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.