메뉴 건너뛰기




Volumn 50, Issue 4, 2006, Pages 531-541

Dynamic viscoelastic shear properties of soft matter by magnetic resonance elastography using a low-field dedicated system

Author keywords

[No Author keywords available]

Indexed keywords

MAGNETIC RESONANCE; MAGNETIC RESONANCE IMAGING; PARAMETER ESTIMATION; RHEOMETERS; SHEAR STRESS; VISCOELASTICITY;

EID: 33749023604     PISSN: 01486055     EISSN: None     Source Type: Journal    
DOI: 10.1122/1.2207187     Document Type: Conference Paper
Times cited : (14)

References (22)
  • 1
    • 84953375254 scopus 로고
    • Velocity and concentration measurements of suspensions by nuclear magnetic resonance
    • Altobelli, S. A., R. C. Givler, and E. Fukushima, ";;Velocity and concentration measurements of suspensions by nuclear magnetic resonance,";; J. Rheol. 35, 721-734 (1991).
    • (1991) J. Rheol. , vol.35 , pp. 721-734
    • Altobelli, S.A.1    Givler, R.C.2    Fukushima, E.3
  • 4
    • 0031274214 scopus 로고    scopus 로고
    • Nuclear magnetic resonance visualization of anomalous flow in cone- And plate rheometry
    • Britton, M. M., and P. T. Callaghan, ";;Nuclear magnetic resonance visualization of anomalous flow in cone- and plate rheometry,";; J. Rheol. 41, 1365-1386 (1997).
    • (1997) J. Rheol. , vol.41 , pp. 1365-1386
    • Britton, M.M.1    Callaghan, P.T.2
  • 6
    • 0000099938 scopus 로고    scopus 로고
    • Rheo-NMR: Nuclear magnetic resonance and the rheology of complex fluids
    • Callaghan, P. T., ";;Rheo-NMR: Nuclear magnetic resonance and the rheology of complex fluids,";; Rep. Prog. Phys. 62, 599-670 (1999).
    • (1999) Rep. Prog. Phys. , vol.62 , pp. 599-670
    • Callaghan, P.T.1
  • 7
    • 0032917608 scopus 로고    scopus 로고
    • A solution to diffraction biases in sonoelasticity: The acoustic impulse technique
    • Catheline, S., F. Wu, and M. Fink, ";;A solution to diffraction biases in sonoelasticity: The acoustic impulse technique,";; J. Acoust. Soc. Am. 105, 2491-2950 (1999).
    • (1999) J. Acoust. Soc. Am. , vol.105 , pp. 2491-2950
    • Catheline, S.1    Wu, F.2    Fink, M.3
  • 8
    • 2942672243 scopus 로고    scopus 로고
    • Quantifying elasticity and viscosity from measurement of shear wave speed dispersion
    • Chen, S., M. Fatemi, and J. F. Greenleaf, ";;Quantifying elasticity and viscosity from measurement of shear wave speed dispersion,";; J. Acoust. Soc. Am. 115, 2781-2785 (2004).
    • (2004) J. Acoust. Soc. Am. , vol.115 , pp. 2781-2785
    • Chen, S.1    Fatemi, M.2    Greenleaf, J.F.3
  • 9
    • 0031316058 scopus 로고    scopus 로고
    • Low-field dedicated and desktop magnetic resonance imaging systems for agricultural and food applications
    • Constantinesco, A., P. Choquet, J. M. Fournier, S. Ravier, J. M. Drillon, and G. Aubeit, ";;Low-field dedicated and desktop magnetic resonance imaging systems for agricultural and food applications,";; Magn. Reson. Chem. 35, 69-75 (1997).
    • (1997) Magn. Reson. Chem. , vol.35 , pp. 69-75
    • Constantinesco, A.1    Choquet, P.2    Fournier, J.M.3    Ravier, S.4    Drillon, J.M.5    Aubeit, G.6
  • 11
    • 0037227693 scopus 로고    scopus 로고
    • Comparison of quantitative shear wave MR-elastography with mechanical compression tests
    • Hamhaber, U., F. Grieshaber, J. Nagel, and U. Klose, ";;Comparison of quantitative shear wave MR-elastography with mechanical compression tests,";; Magn. Reson. Med. 49, 71-77 (2003).
    • (2003) Magn. Reson. Med. , vol.49 , pp. 71-77
    • Hamhaber, U.1    Grieshaber, F.2    Nagel, J.3    Klose, U.4
  • 12
    • 0023312048 scopus 로고
    • A pulsed Doppler ultrasonic system for making noninvasive measurements of the mechanical properties of soft tissue
    • Krouskop, T. A., D. R. Dougherty, and F. S. Vinson, ";;A pulsed Doppler ultrasonic system for making noninvasive measurements of the mechanical properties of soft tissue,";; J. Rehabil. Res. Dev. 24, 1-8 (1987).
    • (1987) J. Rehabil. Res. Dev. , vol.24 , pp. 1-8
    • Krouskop, T.A.1    Dougherty, D.R.2    Vinson, F.S.3
  • 14
    • 0029091703 scopus 로고
    • Sonoelastic determination of human skeletal muscle elasticity
    • Levinson, S. F., M. Shinagawa, and T. Sato, ";;Sonoelastic determination of human skeletal muscle elasticity,";; J. Biomech. 28, 1145-1154 (1995).
    • (1995) J. Biomech. , vol.28 , pp. 1145-1154
    • Levinson, S.F.1    Shinagawa, M.2    Sato, T.3
  • 15
    • 0029654138 scopus 로고
    • Magnetic resonance elastography by direct visualization of propagating acoustic strain waves
    • Muthupillai, R., D. J. Lomas, P. J. Rossman, J. F. Greenleaf, A. Manduca, and R. L. Ehman, ";;Magnetic resonance elastography by direct visualization of propagating acoustic strain waves,";; Science 269, 1854 1857 (1995).
    • (1995) Science , vol.269 , pp. 1854-1857
    • Muthupillai, R.1    Lomas, D.J.2    Rossman, P.J.3    Greenleaf, J.F.4    Manduca, A.5    Ehman, R.L.6
  • 16
    • 24144442898 scopus 로고    scopus 로고
    • Microscopic magnetic resonance elastography (μMRE)
    • Othman, S. F., H. Xu, T. J. Royston, and R. L. Magin, ";;Microscopic magnetic resonance elastography (μMRE),";; Magn. Reson. Med. 54, 605-615 (2005).
    • (2005) Magn. Reson. Med. , vol.54 , pp. 605-615
    • Othman, S.F.1    Xu, H.2    Royston, T.J.3    Magin, R.L.4
  • 17
    • 0027055621 scopus 로고
    • Sonoelasticity of organs: Shear waves ring a bell
    • Parker, K. J., and R. M. Lerner, ";;Sonoelasticity of organs: Shear waves ring a bell,";; J. Ultrasound Med. 11, 387-392 (1992).
    • (1992) J. Ultrasound Med. , vol.11 , pp. 387-392
    • Parker, K.J.1    Lerner, R.M.2
  • 18
    • 18244364148 scopus 로고    scopus 로고
    • Quantitative shear wave magnetic resonance elastography: Comparison to a dynamic shear material test
    • Ringleb, S. I., Q. Chen, D. S. Lake, A. Manduca, R. L. Ehman, and An Kai-Nan, ";;Quantitative shear wave magnetic resonance elastography: Comparison to a dynamic shear material test,";; Magn. Reson. Med. 53, 1197-1201 (2005).
    • (2005) Magn. Reson. Med. , vol.53 , pp. 1197-1201
    • Ringleb, S.I.1    Chen, Q.2    Lake, D.S.3    Manduca, A.4    Ehman, R.L.5    Kai-Nan, A.6
  • 19
    • 17044414054 scopus 로고    scopus 로고
    • Viscoelastic shear properties of in vivo breast lesions measured by MR elastography
    • Sinkus, R., M. Tanter, T. Xydeas, S. Catheline, J. Bercoff, and M. Fink, ";;Viscoelastic shear properties of in vivo breast lesions measured by MR elastography,";; Magn. Reson. Imaging 23, 159-165 (2005).
    • (2005) Magn. Reson. Imaging , vol.23 , pp. 159-165
    • Sinkus, R.1    Tanter, M.2    Xydeas, T.3    Catheline, S.4    Bercoff, J.5    Fink, M.6
  • 20
    • 33646376290 scopus 로고
    • Spin diffusion measurements: Spin echoes in the presence of a time-dependent field gradient
    • Stejskal, E. O., and J. E. Tanner, ";;Spin diffusion measurements: Spin echoes in the presence of a time-dependent field gradient,";; J. Chem. Phys. 42, 288-292 (1965).
    • (1965) J. Chem. Phys. , vol.42 , pp. 288-292
    • Stejskal, E.O.1    Tanner, J.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.