메뉴 건너뛰기




Volumn 21, Issue 3, 2006, Pages 132-138

Do we still need compression bandages? Haemodynamic effects of compression stockings and bandages

(1)  Partsch, H a  

a NONE   (Austria)

Author keywords

Ambulatory venous hypertension; Bandages; Compression therapy; Interface pressure; Stiffness

Indexed keywords

ARTICLE; COMPARATIVE STUDY; COMPRESSION THERAPY; DOPPLER ECHOGRAPHY; DYNAMOMETRY; EDEMA; FLOW RATE; HEMODYNAMICS; LEG; LEG SWELLING; PHLEBOGRAPHY; PLETHYSMOGRAPHY; PRIORITY JOURNAL; PROTECTIVE CLOTHING; SITTING; STANDING; VEIN BLOOD FLOW; VEIN INSUFFICIENCY; VENOUS PRESSURE; VENOUS REFLUX; VOLUMETRY;

EID: 33748777974     PISSN: 02683555     EISSN: 02683555     Source Type: Journal    
DOI: 10.1258/026835506778253283     Document Type: Article
Times cited : (13)

References (28)
  • 1
    • 7644219891 scopus 로고    scopus 로고
    • Efficacy and tolerability of an ulcer compression stocking for therapy of chronic venous ulcer compared with a below-knee compression bandage: Results from a prospective, randomized, multicentre trial
    • Jünger M, Wollina U, Kohnen R, Rabe E. Efficacy and tolerability of an ulcer compression stocking for therapy of chronic venous ulcer compared with a below-knee compression bandage: results from a prospective, randomized, multicentre trial. Curr Med Res Opin 2004;20:1613-24
    • (2004) Curr Med Res Opin , vol.20 , pp. 1613-1624
    • Jünger, M.1    Wollina, U.2    Kohnen, R.3    Rabe, E.4
  • 2
    • 9944265874 scopus 로고    scopus 로고
    • Efficacy of a ready made tubular compression device versus short-stretch compression bandages in the treatment of venous leg ulcers
    • Jünger M, Partsch H, Ramelet AA, Zuccarelli F. Efficacy of a ready made tubular compression device versus short-stretch compression bandages in the treatment of venous leg ulcers. Wounds 2004;16:313-20
    • (2004) Wounds , vol.16 , pp. 313-320
    • Jünger, M.1    Partsch, H.2    Ramelet, A.A.3    Zuccarelli, F.4
  • 3
    • 1542285973 scopus 로고    scopus 로고
    • Leg compression and ambulation is better than bed rest for treatment of acute deep venous thrombosis
    • Blättler W, Partsch H. Leg compression and ambulation is better than bed rest for treatment of acute deep venous thrombosis. Int Angiol 2003;22:393-400
    • (2003) Int Angiol , vol.22 , pp. 393-400
    • Blättler, W.1    Partsch, H.2
  • 5
    • 26944487284 scopus 로고    scopus 로고
    • Calf compression pressure required to achieve venous closure from supine to standing positions
    • Partsch B, Partsch H. Calf compression pressure required to achieve venous closure from supine to standing positions. J Vasc Surg 2005;42:734-8
    • (2005) J Vasc Surg , vol.42 , pp. 734-738
    • Partsch, B.1    Partsch, H.2
  • 6
    • 0036845413 scopus 로고    scopus 로고
    • Does thigh compression improve venous hemodynamics in chronic venous insufficiency?
    • Partsch H, Menzinger G, Borst-Krafek B, Groiss E. Does thigh compression improve venous hemodynamics in chronic venous insufficiency? J Vasc Surg 2002;36:948-52
    • (2002) J Vasc Surg , vol.36 , pp. 948-952
    • Partsch, H.1    Menzinger, G.2    Borst-Krafek, B.3    Groiss, E.4
  • 7
    • 0017367841 scopus 로고
    • Aenderungen der Blutvolumenverteilung im Ganzkörper unter physikalischen und pharmakologischen Maßnahmen
    • Mostbeck A, Partsch H, Peschl L. Aenderungen der Blutvolumenverteilung im Ganzkörper unter physikalischen und pharmakologischen Maßnahmen. VASA 1977;6:137-42
    • (1977) VASA , vol.6 , pp. 137-142
    • Mostbeck, A.1    Partsch, H.2    Peschl, L.3
  • 8
    • 0032880230 scopus 로고    scopus 로고
    • Inelastic leg compression is more effective to reduce deep venous refluxes than elastic bandages
    • Partsch H, Menzinger G, Mostbeck A. Inelastic leg compression is more effective to reduce deep venous refluxes than elastic bandages. Dermatol Surg 1999;25:695-700
    • (1999) Dermatol Surg , vol.25 , pp. 695-700
    • Partsch, H.1    Menzinger, G.2    Mostbeck, A.3
  • 9
    • 0000042869 scopus 로고
    • Venöse Strömungsbeschleunigung in Bein und Becken durch AntiThrombosestrü mpfe
    • Partsch H, Kahn P. Venöse Strömungsbeschleunigung in Bein und Becken durch AntiThrombosestrü mpfe. Klinikarzt 1982;11:609-12
    • (1982) Klinikarzt , vol.11 , pp. 609-612
    • Partsch, H.1    Kahn, P.2
  • 10
    • 0021238621 scopus 로고
    • Do we need firm compression stockings exerting high pressure?
    • Partsch H. Do we need firm compression stockings exerting high pressure? VASA 1984;13:52-7
    • (1984) VASA , vol.13 , pp. 52-57
    • Partsch, H.1
  • 11
    • 0021267280 scopus 로고
    • Improvement of venous pumping function in chronic venous insufficiency by compression depending on pressure and material
    • Partsch H. Improvement of venous pumping function in chronic venous insufficiency by compression depending on pressure and material. VASA 1984;13:58-64
    • (1984) VASA , vol.13 , pp. 58-64
    • Partsch, H.1
  • 12
    • 24344493041 scopus 로고    scopus 로고
    • The use of pressure change on standing as a surrogate measure of the stiffness of a compression bandage
    • Partsch H. The use of pressure change on standing as a surrogate measure of the stiffness of a compression bandage. Eur J Vasc Endovasc Surg 2005;30:415-21
    • (2005) Eur J Vasc Endovasc Surg , vol.30 , pp. 415-421
    • Partsch, H.1
  • 13
    • 33645063474 scopus 로고    scopus 로고
    • Measurement of lower leg compression in vivo: Recommendations for the performance of measurements of interface pressure and stiffness: Consensus statement
    • Partsch H, Clark M, Bassez S, et al. Measurement of lower leg compression in vivo: recommendations for the performance of measurements of interface pressure and stiffness: consensus statement. Dermatol Surg 2006;32(2):229-238
    • (2006) Dermatol Surg , vol.32 , Issue.2 , pp. 229-238
    • Partsch, H.1    Clark, M.2    Bassez, S.3
  • 14
    • 2442669280 scopus 로고    scopus 로고
    • Compression stockings reduce occupational swelling
    • Partsch H, Winiger J, Lun B. Compression stockings reduce occupational swelling. J Derm Surg 2004;30:737-43
    • (2004) J Derm Surg , vol.30 , pp. 737-743
    • Partsch, H.1    Winiger, J.2    Lun, B.3
  • 15
    • 0028360956 scopus 로고
    • Microangiopathy of the skin and the effect of leg compression in patients with chronic venous insufficiency
    • Abu-Own A, Shami SK, Chittenden SJ, Farrah J, Scurr JH, Smith PD. Microangiopathy of the skin and the effect of leg compression in patients with chronic venous insufficiency. J Vasc Surg 1994;19:1074-1083
    • (1994) J Vasc Surg , vol.19 , pp. 1074-1083
    • Abu-Own, A.1    Shami, S.K.2    Chittenden, S.J.3    Farrah, J.4    Scurr, J.H.5    Smith, P.D.6
  • 16
    • 33748787796 scopus 로고    scopus 로고
    • Influence of compression stockings on the diameter of gastrocnemius muscle veins
    • San Diego Abstracts
    • Jeanneret CH, von Planta I. Influence of compression stockings on the diameter of gastrocnemius muscle veins. UIP World Congress Chapter Meeting, San Diego 2003, Abstracts, p 102
    • (2003) UIP World Congress Chapter Meeting , pp. 102
    • Jeanneret, C.H.1    Von Planta, I.2
  • 17
    • 0017660368 scopus 로고
    • Compression treatment in venous insufficiency evaluated with foot volumetry
    • Gjöres JE, Thulesius O. Compression treatment in venous insufficiency evaluated with foot volumetry. VASA 1977;6:364-8
    • (1977) VASA , vol.6 , pp. 364-368
    • Gjöres, J.E.1    Thulesius, O.2
  • 19
    • 0026783843 scopus 로고
    • Improvement of ambulatory venous hypertension by narrowing of the femoral vein in congenital absence of venous valves
    • Partsch B, Mayer W, Partsch H. Improvement of ambulatory venous hypertension by narrowing of the femoral vein in congenital absence of venous valves. Phlebology 1992;7:101-4
    • (1992) Phlebology , vol.7 , pp. 101-104
    • Partsch, B.1    Mayer, W.2    Partsch, H.3
  • 20
  • 21
    • 0034565939 scopus 로고    scopus 로고
    • Elastic compression stockings for prevention of deep vein thrombosis
    • Oxford: Update Sofware
    • Amagiri SV, Lees TA. Elastic compression stockings for prevention of deep vein thrombosis. The Cochrane Library, Issue 2. Oxford: Update Sofware, 2003
    • (2003) The Cochrane Library , Issue.2
    • Amagiri, S.V.1    Lees, T.A.2
  • 22
    • 2442701314 scopus 로고    scopus 로고
    • Etude comparative de léfficacité des chasettes de compression de classe 1 sur la symptomatologie de la maladie veineuse chronique débutante
    • Benigni JP, Sadoun S, Allaert FA, Vin F. Etude comparative de léfficacité des chasettes de compression de classe 1 sur la symptomatologie de la maladie veineuse chronique débutante. Phlébologie 2003;56:117-125
    • (2003) Phlébologie , vol.56 , pp. 117-125
    • Benigni, J.P.1    Sadoun, S.2    Allaert, F.A.3    Vin, F.4
  • 23
    • 0032881193 scopus 로고    scopus 로고
    • Clinical benefits of lightweight compression: Reduction of venous-related symptoms by ready-to-wear lightweight gradient compression hosiery
    • Weiss RA, Duffy D. Clinical benefits of lightweight compression: reduction of venous-related symptoms by ready-to-wear lightweight gradient compression hosiery. Derm Surg 1999;25:701-4
    • (1999) Derm Surg , vol.25 , pp. 701-704
    • Weiss, R.A.1    Duffy, D.2
  • 24
    • 2442548958 scopus 로고    scopus 로고
    • A method for measuring the dynamic behavior of medical compression hosiery during walking
    • Stolk R, Wegen van der-Franken CPM, Neumann HAM. A method for measuring the dynamic behavior of medical compression hosiery during walking. Derm Surg 2004;30:729-36
    • (2004) Derm Surg , vol.30 , pp. 729-736
    • Stolk, R.1    Wegen Van Der-Franken, C.P.M.2    Neumann, H.A.M.3
  • 25
    • 33748758812 scopus 로고    scopus 로고
    • Warum kommt es zu einem Druckabfall unter Kompressionsverbänden?
    • Brouwer E, Damstra R, Partsch H. Warum kommt es zu einem Druckabfall unter Kompressionsverbänden? Vasomed 2005;17:128-9
    • (2005) Vasomed , vol.17 , pp. 128-129
    • Brouwer, E.1    Damstra, R.2    Partsch, H.3
  • 27
    • 0033861704 scopus 로고    scopus 로고
    • A comparison of multilayer bandage systems during rest, exercise, and over 2 days of wear time
    • Hafner J, Botonakis I, Burg G. A comparison of multilayer bandage systems during rest, exercise, and over 2 days of wear time. Arch Dermatol 2000;136:857-63
    • (2000) Arch Dermatol , vol.136 , pp. 857-863
    • Hafner, J.1    Botonakis, I.2    Burg, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.