-
1
-
-
0034952949
-
Treatment of painful osteoporotic vertebral fractures with percutaneous vertebroplasty or kyphoplasty
-
Watts NB, Harris ST, Genant HK. Treatment of painful osteoporotic vertebral fractures with percutaneous vertebroplasty or kyphoplasty. Osteoporos Int 2001;12(6):429-37.
-
(2001)
Osteoporos Int
, vol.12
, Issue.6
, pp. 429-437
-
-
Watts, N.B.1
Harris, S.T.2
Genant, H.K.3
-
2
-
-
0026167803
-
Evaluation of adverse health outcomes associated with vertebral fractures
-
Ross PD, Ettinger B, Davis JW, Melton III LJ, Wasnich RD. Evaluation of adverse health outcomes associated with vertebral fractures. Osteoporos Int. 1991;1(3):134-40.
-
(1991)
Osteoporos Int
, vol.1
, Issue.3
, pp. 134-140
-
-
Ross, P.D.1
Ettinger, B.2
Davis, J.W.3
Melton III, L.J.4
Wasnich, R.D.5
-
3
-
-
0025020364
-
A study of complaints and their relation to vertebral destruction in patients with osteoporosis
-
Leidig G, Minne HW, Sauer P, Wuster C, Wuster J, Lojen M, et al. A study of complaints and their relation to vertebral destruction in patients with osteoporosis. Bone Mineral. 1990;8(3):217-29.
-
(1990)
Bone Mineral
, vol.8
, Issue.3
, pp. 217-229
-
-
Leidig, G.1
Minne, H.W.2
Sauer, P.3
Wuster, C.4
Wuster, J.5
Lojen, M.6
-
4
-
-
0043165850
-
Note preliminaire sur le traitement des angiomes vertebraux par vertebroplastie acrylique percutanee
-
Galibert P, Deramond H, Rosat P, Le Gars D. Note preliminaire sur le traitement des angiomes vertebraux par vertebroplastie acrylique percutanee. Neurochirurgie. 1987;33(2):166-8.
-
(1987)
Neurochirurgie
, vol.33
, Issue.2
, pp. 166-168
-
-
Galibert, P.1
Deramond, H.2
Rosat, P.3
Le Gars, D.4
-
5
-
-
0031225248
-
Vertebroplasty relieves osteoporosis pain
-
San Francisco
-
Jensen ME, Dion JE. Vertebroplasty relieves osteoporosis pain. Diagn Imaging (San Francisco) 1997;19(9):68, 71-2.
-
(1997)
Diagn Imaging
, vol.19
, Issue.9
, pp. 68
-
-
Jensen, M.E.1
Dion, J.E.2
-
6
-
-
0031545893
-
Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: Technical aspects
-
Jensen ME, Evans AJ, Mathis JM, Kallmes DF, Cloft HJ, Dion JE. Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects. AJNR Am J Neuroradiol. 1997;18(10):1897-904.
-
(1997)
AJNR Am J Neuroradiol
, vol.18
, Issue.10
, pp. 1897-1904
-
-
Jensen, M.E.1
Evans, A.J.2
Mathis, J.M.3
Kallmes, D.F.4
Cloft, H.J.5
Dion, J.E.6
-
7
-
-
0031431778
-
Future directions. Augmentation of osteoporotic vertebral bodies
-
Bostrom MP, Lane JM. Future directions. Augmentation of osteoporotic vertebral bodies. Spine. 1997;22(24 Suppl):38S-42S.
-
(1997)
Spine
, vol.22
, Issue.24 SUPPL.
-
-
Bostrom, M.P.1
Lane, J.M.2
-
8
-
-
0031961970
-
Percutaneous vertebroplasty treatment of steroid-induced osteoporotic compression fractures
-
Mathis JM, Petri M, Naff N. Percutaneous vertebroplasty treatment of steroid-induced osteoporotic compression fractures. Arthritis Rheum. 1998;41(1):171-5.
-
(1998)
Arthritis Rheum
, vol.41
, Issue.1
, pp. 171-175
-
-
Mathis, J.M.1
Petri, M.2
Naff, N.3
-
9
-
-
0000050852
-
Percutaneous Vertebroplasty
-
Deramond H, Depriester C, Toussaint P, Galibert P. Percutaneous Vertebroplasty. Semin Musculoskelet Radiol. 1997;1(2):285-296.
-
(1997)
Semin Musculoskelet Radiol
, vol.1
, Issue.2
, pp. 285-296
-
-
Deramond, H.1
Depriester, C.2
Toussaint, P.3
Galibert, P.4
-
10
-
-
0033771647
-
Percutaneous transpedicular vertebroplasty with PMMA: Operative technique and early results. A prospective study for the treatment of osteoporotic compression fractures
-
Heini PF, Walchli B, Berlemann U. Percutaneous transpedicular vertebroplasty with PMMA: operative technique and early results. A prospective study for the treatment of osteoporotic compression fractures. Eur Spine J. 2000;9(5):445-50.
-
(2000)
Eur Spine J
, vol.9
, Issue.5
, pp. 445-450
-
-
Heini, P.F.1
Walchli, B.2
Berlemann, U.3
-
11
-
-
0014463475
-
The relative contribution of trabecular and cortical bone strength to the strength of human lumbar vertebrae
-
Rockoff SD, Sweet E, Bleustein J. The relative contribution of trabecular and cortical bone strength to the strength of human lumbar vertebrae. Calcif Tissue Res. 1969;3:163-75.
-
(1969)
Calcif Tissue Res
, vol.3
, pp. 163-175
-
-
Rockoff, S.D.1
Sweet, E.2
Bleustein, J.3
-
12
-
-
0035054442
-
Augmentation of mechanical properties in osteoporotic vertebral bones - A biomechanical investigation of vertebroplasty efficacy with different bone cements
-
Heini PF, Berlemann U, Kaufmann M, Lippuner K, Fankhauser C, van Landuyt P. Augmentation of mechanical properties in osteoporotic vertebral bones - a biomechanical investigation of vertebroplasty efficacy with different bone cements. Eur Spine J. 2001;10(2):164-71.
-
(2001)
Eur Spine J
, vol.10
, Issue.2
, pp. 164-171
-
-
Heini, P.F.1
Berlemann, U.2
Kaufmann, M.3
Lippuner, K.4
Fankhauser, C.5
Van Landuyt, P.6
-
13
-
-
13444261294
-
Injection biomechanics of bone cements used in vertebroplasty
-
Baroud G, Bohner M, Heini P, Steffen T. Injection biomechanics of bone cements used in vertebroplasty. Bio-Medical Materials Eng. 2004;14(4):487-504.
-
(2004)
Bio-Medical Materials Eng
, vol.14
, Issue.4
, pp. 487-504
-
-
Baroud, G.1
Bohner, M.2
Heini, P.3
Steffen, T.4
-
14
-
-
0037411334
-
Theoretical and experimental model to describe the injection of a polymethylmethacrylate cement into a porous structure
-
Bohner M, Gasser B, Baroud G, Heini P. Theoretical and experimental model to describe the injection of a polymethylmethacrylate cement into a porous structure. Biomaterials. 2003;24(16):2721-30.
-
(2003)
Biomaterials
, vol.24
, Issue.16
, pp. 2721-2730
-
-
Bohner, M.1
Gasser, B.2
Baroud, G.3
Heini, P.4
-
15
-
-
0036672744
-
Influence of cement viscosity on cement interdigitation and venous fat content under in vivo conditions
-
Breusch S, Heisel C, Mueller J, Borchers T, Mau H. Influence of cement viscosity on cement interdigitation and venous fat content under in vivo conditions. Acta Orthop Scand. 2002;73:409-15.
-
(2002)
Acta Orthop Scand
, vol.73
, pp. 409-415
-
-
Breusch, S.1
Heisel, C.2
Mueller, J.3
Borchers, T.4
Mau, H.5
-
16
-
-
0033366518
-
Pulmonary embolism caused by acrylic cement: A rare complication of percutaneous vertebroplasty
-
Padovani B, Kasriel O, Brunner P, Peretti-Viton P. Pulmonary embolism caused by acrylic cement: a rare complication of percutaneous vertebroplasty. AJNR Am J Neuroradiol. 1999;20(3):375-7.
-
(1999)
AJNR Am J Neuroradiol
, vol.20
, Issue.3
, pp. 375-377
-
-
Padovani, B.1
Kasriel, O.2
Brunner, P.3
Peretti-Viton, P.4
-
17
-
-
33748640447
-
Load shift after augmenting osteoporotic vertebrae
-
Davos, Switzerland
-
Baroud G, Steffen T. Load shift after augmenting osteoporotic vertebrae. In: Biomechanica IV; 2001; Davos, Switzerland.
-
(2001)
Biomechanica IV
-
-
Baroud, G.1
Steffen, T.2
-
18
-
-
33748666058
-
Adjacent stiffness and load shift after a vertebral cement augmentation
-
Middleton J, et al., editors. London: Gordon and Breach
-
Baroud G, Smit T, Heini P, Steffen T. Adjacent stiffness and load shift after a vertebral cement augmentation. In: Middleton J, et al., editors. Computer methods in biomechanics and biomedical engineering. London: Gordon and Breach; 2002.
-
(2002)
Computer Methods in Biomechanics and Biomedical Engineering
-
-
Baroud, G.1
Smit, T.2
Heini, P.3
Steffen, T.4
-
19
-
-
0036328899
-
Adjacent vertebral failure after vertebroplasty. A biomechanical investigation
-
Berlemann U, Ferguson SJ, Nolte LP, Heini PF. Adjacent vertebral failure after vertebroplasty. A biomechanical investigation. J Bone Joint Surg Br. 2002;84(5):748-52.
-
(2002)
J Bone Joint Surg Br
, vol.84
, Issue.5
, pp. 748-752
-
-
Berlemann, U.1
Ferguson, S.J.2
Nolte, L.P.3
Heini, P.F.4
-
20
-
-
0038638437
-
Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty
-
Belkoff SM, Molloy S. Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty. Spine. 2003;28(14):1555-9.
-
(2003)
Spine
, vol.28
, Issue.14
, pp. 1555-1559
-
-
Belkoff, S.M.1
Molloy, S.2
-
21
-
-
0032807670
-
Temperature elevation caused by bone cement polymerization during vertebroplasty
-
Deramond H, Wright NT, Belkoff SM. Temperature elevation caused by bone cement polymerization during vertebroplasty. Bone. 1999;25(2 Suppl):17S-21S.
-
(1999)
Bone
, vol.25
, Issue.2 SUPPL.
-
-
Deramond, H.1
Wright, N.T.2
Belkoff, S.M.3
-
22
-
-
0346725969
-
Influence of mixing method on the cement temperature-mixing time history and doughing time of three acrylic cements for vertebroplasty
-
Baroud G, Samara M, Steffen T. Influence of mixing method on the cement temperature-mixing time history and doughing time of three acrylic cements for vertebroplasty. J Biomed Mater Res. 2004;68B(1):112-6.
-
(2004)
J Biomed Mater Res
, vol.68
, Issue.1 B
, pp. 112-116
-
-
Baroud, G.1
Samara, M.2
Steffen, T.3
-
23
-
-
0033200346
-
Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures
-
Tohmeh AG, Mathis JM, Fenton DC, Levine AM, Belkoff SM. Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures. Spine. 1999;24(17):1772-6.
-
(1999)
Spine
, vol.24
, Issue.17
, pp. 1772-1776
-
-
Tohmeh, A.G.1
Mathis, J.M.2
Fenton, D.C.3
Levine, A.M.4
Belkoff, S.M.5
-
24
-
-
0032782296
-
Pathology findings with acrylic implants
-
San Millan Ruiz D, Burkhardt K, Jean B, Muster M, Martin JB, Bouvier J, Fasel JH, Rufenacht DA, Kurt AM. Pathology findings with acrylic implants. Bone. 1999;25(2 Suppl):85S-90S.
-
(1999)
Bone
, vol.25
, Issue.2 SUPPL.
-
-
San Millan Ruiz, D.1
Burkhardt, K.2
Jean, B.3
Muster, M.4
Martin, J.B.5
Bouvier, J.6
Fasel, J.H.7
Rufenacht, D.A.8
Kurt, A.M.9
-
25
-
-
0034515155
-
Long-term observations of vertebral osteoporotic fractures treated by percutaneous vertebroplasty
-
Oxford
-
Grados F, Depriester C, Cayrolle G, Hardy N, Deramond H, Fardellone P. Long-term observations of vertebral osteoporotic fractures treated by percutaneous vertebroplasty. Rheumatology (Oxford). 2000;39(12):1410-4.
-
(2000)
Rheumatology
, vol.39
, Issue.12
, pp. 1410-1414
-
-
Grados, F.1
Depriester, C.2
Cayrolle, G.3
Hardy, N.4
Deramond, H.5
Fardellone, P.6
-
26
-
-
0037260469
-
Occurrence of new vertebral body fracture after percutaneous vertebroplasty in patients with osteoporosis
-
Uppin AA, Hirsch JA, Centenera LV, Pfiefer BA, Pazianos AG, Choi IS. Occurrence of new vertebral body fracture after percutaneous vertebroplasty in patients with osteoporosis. Radiology. 2003;226(1):119-24.
-
(2003)
Radiology
, vol.226
, Issue.1
, pp. 119-124
-
-
Uppin, A.A.1
Hirsch, J.A.2
Centenera, L.V.3
Pfiefer, B.A.4
Pazianos, A.G.5
Choi, I.S.6
-
27
-
-
4444317638
-
Risk factors of new compression fractures in adjacent vertebrae after percutaneous vertebroplasty
-
Kim SH, Kang HS, Choi J-A, Ahn JM. Risk factors of new compression fractures in adjacent vertebrae after percutaneous vertebroplasty. Acta Radiologica. 2004;45(4):440-5(6).
-
(2004)
Acta Radiologica
, vol.45
, Issue.4
, pp. 440-456
-
-
Kim, S.H.1
Kang, H.S.2
Choi, J.-A.3
Ahn, J.M.4
-
28
-
-
33645239259
-
Biomechanical impact of vertebroplasty. Postoperative biomechanics of vertebroplasty
-
Baroud G, Bohner M. Biomechanical impact of vertebroplasty. Postoperative biomechanics of vertebroplasty. Joint Bone Spine. 2006;73:144-50.
-
(2006)
Joint Bone Spine
, vol.73
, pp. 144-150
-
-
Baroud, G.1
Bohner, M.2
-
29
-
-
0042795013
-
Physical changes of the vertebral tissue treated with vertebroplasty
-
Zurich, Switzerland
-
Baroud G, Goerke U, Beckman L, Steffen T. Physical changes of the vertebral tissue treated with vertebroplasty. In: XVIIIth Congress of International Society of Biomechanics; 2001; Zurich, Switzerland; p. 728.
-
(2001)
XVIIIth Congress of International Society of Biomechanics
, pp. 728
-
-
Baroud, G.1
Goerke, U.2
Beckman, L.3
Steffen, T.4
-
30
-
-
1242329821
-
The biomechanics of vertebroplasty: A review
-
Proc Inst Mech Eng: Part H
-
Wilcox RK. The biomechanics of vertebroplasty: a review. Proc Inst Mech Eng: Part H. J Eng Med. 2004;218(1):1-10.
-
(2004)
J Eng Med
, vol.218
, Issue.1
, pp. 1-10
-
-
Wilcox, R.K.1
-
31
-
-
0034193728
-
Biomechanical evaluation of a new bone cement for use in vertebroplasty
-
Belkoff SM, Mathis JM, Erbe EM, Fenton DC. Biomechanical evaluation of a new bone cement for use in vertebroplasty. Spine. 2000;25(9):1061-4.
-
(2000)
Spine
, vol.25
, Issue.9
, pp. 1061-1064
-
-
Belkoff, S.M.1
Mathis, J.M.2
Erbe, E.M.3
Fenton, D.C.4
-
32
-
-
0035879117
-
The biomechanics of vertebroplasty. The effect of cement volume on mechanical behavior
-
Belkoff SM, Mathis JM, Jasper LE, Deramond H. The biomechanics of vertebroplasty. The effect of cement volume on mechanical behavior. Spine. 2001;26(14):1537-41.
-
(2001)
Spine
, vol.26
, Issue.14
, pp. 1537-1541
-
-
Belkoff, S.M.1
Mathis, J.M.2
Jasper, L.E.3
Deramond, H.4
-
33
-
-
0036846092
-
Ex vivo biomechanical comparison of hydroxyapatite and polymethylmethacrylate cements for use with vertebroplasty
-
Belkoff SM, Mathis JM, Jasper LE. Ex vivo biomechanical comparison of hydroxyapatite and polymethylmethacrylate cements for use with vertebroplasty. AJNR Am J Neuroradiol 2002;23(10):1647-51.
-
(2002)
AJNR Am J Neuroradiol
, vol.23
, Issue.10
, pp. 1647-1651
-
-
Belkoff, S.M.1
Mathis, J.M.2
Jasper, L.E.3
-
34
-
-
0034520393
-
The strengthening effect of percutaneous vertebroplasty
-
Dean JR, Ison KT, Gishen P. The strengthening effect of percutaneous vertebroplasty. Clin Radiol. 2000;55(6):471-6.
-
(2000)
Clin Radiol
, vol.55
, Issue.6
, pp. 471-476
-
-
Dean, J.R.1
Ison, K.T.2
Gishen, P.3
-
35
-
-
0037096636
-
Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty
-
Lim TH, Brebach GT, Renner SM, Kim WJ, Kim JG, Lee RE, Andersson GB, An HS. Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty. Spine. 2002;27(12):1297-302.
-
(2002)
Spine
, vol.27
, Issue.12
, pp. 1297-1302
-
-
Lim, T.H.1
Brebach, G.T.2
Renner, S.M.3
Kim, W.J.4
Kim, J.G.5
Lee, R.E.6
Andersson, G.B.7
An, H.S.8
-
36
-
-
0032810055
-
The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures
-
Bai B, Jazrawi LM, Kummer FJ, Spivak JM. The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures. Spine. 1999;24(15):1521-6.
-
(1999)
Spine
, vol.24
, Issue.15
, pp. 1521-1526
-
-
Bai, B.1
Jazrawi, L.M.2
Kummer, F.J.3
Spivak, J.M.4
-
37
-
-
0035863342
-
An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture
-
Belkoff SM, Mathis JM, Fenton DC, Scribner RM, Reiley ME, Talmadge K. An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture. Spine. 2001;26(2):151-6.
-
(2001)
Spine
, vol.26
, Issue.2
, pp. 151-156
-
-
Belkoff, S.M.1
Mathis, J.M.2
Fenton, D.C.3
Scribner, R.M.4
Reiley, M.E.5
Talmadge, K.6
-
38
-
-
0037263256
-
Biomechanical evaluation of kyphoplasty and vertebroplasty with calcium phosphate cement in a simulated osteoporotic compression fracture
-
Tomita S, Kin A, Yazu M, Abe M. Biomechanical evaluation of kyphoplasty and vertebroplasty with calcium phosphate cement in a simulated osteoporotic compression fracture. J Orthop Sci. 2003;8(2):192-7.
-
(2003)
J Orthop Sci
, vol.8
, Issue.2
, pp. 192-197
-
-
Tomita, S.1
Kin, A.2
Yazu, M.3
Abe, M.4
-
39
-
-
0037962372
-
Biomechanical effects of unipedicular vertebroplasty on intact vertebrae
-
Higgins KB, Harten RD, Langrana NA, Reiter MF. Biomechanical effects of unipedicular vertebroplasty on intact vertebrae. Spine. 2003;28(14):1540-1548.
-
(2003)
Spine
, vol.28
, Issue.14
, pp. 1540-1548
-
-
Higgins, K.B.1
Harten, R.D.2
Langrana, N.A.3
Reiter, M.F.4
-
40
-
-
0032803123
-
An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty
-
Belkoff SM, Maroney M, Fenton DC, Mathis JM. An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty. Bone. 1999;25(2 Suppl):23S-26S.
-
(1999)
Bone
, vol.25
, Issue.2 SUPPL.
-
-
Belkoff, S.M.1
Maroney, M.2
Fenton, D.C.3
Mathis, J.M.4
-
41
-
-
0035879286
-
An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty
-
Belkoff SM, Mathis JM, Jasper LE, Deramond H. An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty. Spine. 2001;26(14):1542-6.
-
(2001)
Spine
, vol.26
, Issue.14
, pp. 1542-1546
-
-
Belkoff, S.M.1
Mathis, J.M.2
Jasper, L.E.3
Deramond, H.4
-
42
-
-
0038638438
-
The effect of vertebral body percentage fill on mechanica behavior during percutaneous vertebroplasty
-
Molloy S, Mathis JM, Belkoff SM. The effect of vertebral body percentage fill on mechanica behavior during percutaneous vertebroplasty. Spine. 2003:28(14):1549-1554.
-
(2003)
Spine
, vol.28
, Issue.14
, pp. 1549-1554
-
-
Molloy, S.1
Mathis, J.M.2
Belkoff, S.M.3
-
43
-
-
0042737757
-
Load shift of the intervertebral disc after a vertebroplasty: A finite-element study
-
Baroud G, Nemes J, Heini P, Steffen T. Load shift of the intervertebral disc after a vertebroplasty: a finite-element study. Eur Spine J. 2003;12(4):421-6.
-
(2003)
Eur Spine J
, vol.12
, Issue.4
, pp. 421-426
-
-
Baroud, G.1
Nemes, J.2
Heini, P.3
Steffen, T.4
-
44
-
-
0035489425
-
Comparison of the biomechanics of hydroxyapatite and polymethylmethacrylate vertebroplasty in a cadaveric spinal compression fracture model
-
Hitchon PW, Goel V, Drake J, Taggard D, Brenton M, Rogge T, Torner JC. Comparison of the biomechanics of hydroxyapatite and polymethylmethacrylate vertebroplasty in a cadaveric spinal compression fracture model. J Neurosurg. 2001;95(2 Suppl):215-20.
-
(2001)
J Neurosurg
, vol.95
, Issue.2 SUPPL.
, pp. 215-220
-
-
Hitchon, P.W.1
Goel, V.2
Drake, J.3
Taggard, D.4
Brenton, M.5
Rogge, T.6
Torner, J.C.7
-
45
-
-
0035893684
-
Bioactive bone cement as a principal fixture for spinal burst fracture: An in vitro biomechanical and morphologic study
-
Lu WW, Cheung KM, Li YW, Luk KD, Holmes AD, Zhu QA, Leong JC. Bioactive bone cement as a principal fixture for spinal burst fracture: an in vitro biomechanical and morphologic study. Spine. 2001;26(24):2684-90; discussion 2690-1.
-
(2001)
Spine
, vol.26
, Issue.24
, pp. 2684-2690
-
-
Lu, W.W.1
Cheung, K.M.2
Li, Y.W.3
Luk, K.D.4
Holmes, A.D.5
Zhu, Q.A.6
Leong, J.C.7
-
47
-
-
85039321382
-
Biomechanical evaluation of vertebro- And kyphoplasty under cyclic loading
-
Vancouver, BC, Canada: Abstract 235
-
Wilke H-J, Mehnert U, Boszczyk BM, Bierschneider M, Jaksche H, Claes LE. Biomechanical evaluation of vertebro- and kyphoplasty under cyclic loading. In: 30th Annual Meeting of the International Society for the Study of the Lumbar Spine; 2003; Vancouver, BC, Canada: Abstract 235.
-
(2003)
30th Annual Meeting of the International Society for the Study of the Lumbar Spine
-
-
Wilke, H.-J.1
Mehnert, U.2
Boszczyk, B.M.3
Bierschneider, M.4
Jaksche, H.5
Claes, L.E.6
-
49
-
-
2942532705
-
Evolution of vertebroplasty: A biomechanical prespective
-
Sun K, Liebschner AK. Evolution of vertebroplasty: A biomechanical prespective. Annals of Biomed Eng. 2004:32(1):77-91.
-
(2004)
Annals of Biomed Eng
, vol.32
, Issue.1
, pp. 77-91
-
-
Sun, K.1
Liebschner, A.K.2
-
50
-
-
0035879306
-
Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty
-
Liebschner MA, Rosenberg WS, Keaveny TM. Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty. Spine. 2001;26(14):1547-54
-
(2001)
Spine
, vol.26
, Issue.14
, pp. 1547-1554
-
-
Liebschner, M.A.1
Rosenberg, W.S.2
Keaveny, T.M.3
-
51
-
-
0037648845
-
The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: Finite-element analysis
-
Polikeit A, Nolte LP, Ferguson SJ. The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: finite-element analysis. Spine. 2003;28(10):991-6.
-
(2003)
Spine
, vol.28
, Issue.10
, pp. 991-996
-
-
Polikeit, A.1
Nolte, L.P.2
Ferguson, S.J.3
-
52
-
-
13844276734
-
Do vertebroplasty cements have the optimum mechanical properties?
-
Sydney, Australia: Abstract 1547
-
Wilcox RK, Do vertebroplasty cements have the optimum mechanical properties? In: Transactions of 7th World Biomaterials Congress; 2004; Sydney, Australia: Abstract 1547.
-
(2004)
Transactions of 7th World Biomaterials Congress
-
-
Wilcox, R.K.1
-
53
-
-
0034951131
-
An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty
-
Belkoff SM, Mathis JM, Deramond H, Jasper LE. An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty. AJNR Am J Neuroradiol. 2001;22(6):1212-6.
-
(2001)
AJNR Am J Neuroradiol
, vol.22
, Issue.6
, pp. 1212-1216
-
-
Belkoff, S.M.1
Mathis, J.M.2
Deramond, H.3
Jasper, L.E.4
-
54
-
-
1042267309
-
Vertebroplastik bei hochgradiger Osteoporose Technik und Erfahrung mit plurisegmentalen Injektionen
-
Heini PF, Orler R. Vertebroplastik bei hochgradiger Osteoporose Technik und Erfahrung mit plurisegmentalen Injektionen. Orthopade. 2004;33(1):22-30.
-
(2004)
Orthopade
, vol.33
, Issue.1
, pp. 22-30
-
-
Heini, P.F.1
Orler, R.2
-
55
-
-
0035900949
-
Risk of new vertebral fracture in the year following a fracture
-
Lindsay R, Silverman SL, Cooper C, Hanley DA, Barton I, Broy SB, Licata A, Benhamou L, Geusens P, et al. Risk of new vertebral fracture in the year following a fracture. JAMA. 2001;285(3):320-3.
-
(2001)
JAMA
, vol.285
, Issue.3
, pp. 320-323
-
-
Lindsay, R.1
Silverman, S.L.2
Cooper, C.3
Hanley, D.A.4
Barton, I.5
Broy, S.B.6
Licata, A.7
Benhamou, L.8
Geusens, P.9
-
56
-
-
0027210851
-
Predicting vertebral fracture incidence from prevalent fractures and bone density among non-black, osteoporotic women
-
Ross PD, Genant HK, Davis JW, Miller PD, Wasnich RD. Predicting vertebral fracture incidence from prevalent fractures and bone density among non-black, osteoporotic women. Osteoporos Int. 1993;3(3):120-6.
-
(1993)
Osteoporos Int
, vol.3
, Issue.3
, pp. 120-126
-
-
Ross, P.D.1
Genant, H.K.2
Davis, J.W.3
Miller, P.D.4
Wasnich, R.D.5
-
57
-
-
0016972929
-
Poly(methyl methacrylate) - Aqueous phase blends: In situ curing porous materials
-
De Wijn, JR. Poly(methyl methacrylate) - aqueous phase blends: in situ curing porous materials. J Biomed Mater Res. 1976;10(4):625-35.
-
(1976)
J Biomed Mater Res
, vol.10
, Issue.4
, pp. 625-635
-
-
De Wijn, J.R.1
-
59
-
-
0034653222
-
Use of alpha-tricalcium phosphate (TCP) as powders and as an aqueous dispersion to modify processing, microstructure, and mechanical properties of polymethylmethacrylate (PMMA) bone cements and to produce bone-substitute compounds
-
Beruto DT, Mezzasalma SA, Capurro M, Botter R, Cirillo P. Use of alpha-tricalcium phosphate (TCP) as powders and as an aqueous dispersion to modify processing, microstructure, and mechanical properties of polymethylmethacrylate (PMMA) bone cements and to produce bone-substitute compounds. J Biomed Mater Res. 2000;49(4):498-505.
-
(2000)
J Biomed Mater Res
, vol.49
, Issue.4
, pp. 498-505
-
-
Beruto, D.T.1
Mezzasalma, S.A.2
Capurro, M.3
Botter, R.4
Cirillo, P.5
|