메뉴 건너뛰기




Volumn 32, Issue 1, 2006, Pages 93-103

Quantification of mechanical vibration during diffusion tensor imaging at 3 T

Author keywords

Diffusion tensor imaging; DTI; Magnetic resonance imaging; Mechanical vibration

Indexed keywords

ANIMAL; ARTICLE; BIOLOGICAL MODEL; BRAIN; BUILDING MATERIAL; COMPARATIVE STUDY; DIFFUSION; EQUIPMENT DESIGN; HISTOLOGY; HUMAN; INSTRUMENTATION; METHODOLOGY; MOVEMENT (PHYSIOLOGY); NUCLEAR MAGNETIC RESONANCE IMAGING; PHYSIOLOGY; VIBRATION;

EID: 33748640992     PISSN: 10538119     EISSN: 10959572     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2006.03.004     Document Type: Article
Times cited : (37)

References (18)
  • 1
    • 0036335681 scopus 로고    scopus 로고
    • A model-based method for retrospective correction of geometric distortions in diffusion-weighted EPI
    • Andersson, J.L., Skare, S., 2002. A model-based method for retrospective correction of geometric distortions in diffusion-weighted EPI. Neuro-Image 16, 177- 199.
    • (2002) Neuro-Image , vol.16 , pp. 177-199
    • Andersson, J.L.1    Skare, S.2
  • 2
    • 0022501525 scopus 로고
    • Respiratory effects in two-dimensional Fourier transform MR imaging
    • Axel, L., Summers, R.M., Kressel, H.Y., Charles, C., 1986. Respiratory effects in two-dimensional Fourier transform MR imaging. Radiology 160, 795- 801.
    • (1986) Radiology , vol.160 , pp. 795-801
    • Axel, L.1    Summers, R.M.2    Kressel, H.Y.3    Charles, C.4
  • 3
    • 0028154030 scopus 로고
    • MR diffusion tensor spectroscopy and imaging
    • Basser, P.J., Mattiello, J., LeBihan, D., 1994. MR diffusion tensor spectroscopy and imaging. Biophys. J. 66, 259- 267.
    • (1994) Biophys. J. , vol.66 , pp. 259-267
    • Basser, P.J.1    Mattiello, J.2    LeBihan, D.3
  • 4
    • 0036233679 scopus 로고    scopus 로고
    • High-resolution isotropic 3D diffusion tensor imaging of the human brain
    • Golay, X., Jiang, H., Van Zilj, P.C., Mori, S., 2002. High-resolution isotropic 3D diffusion tensor imaging of the human brain. Magn. Reson. Med. 47, 837- 843.
    • (2002) Magn. Reson. Med , vol.47 , pp. 837-843
    • Golay, X.1    Jiang, H.2    Van Zilj, P.C.3    Mori, S.4
  • 5
    • 0034767814 scopus 로고    scopus 로고
    • Diffusiontensor MR imaging at 1.5 and 3.0 T: initial observations
    • Hunsche, S., Moseley, M.E., Stoeter, P., Hedehus, M., 2001. Diffusiontensor MR imaging at 1.5 and 3.0 T: initial observations. Radiology 221, 550- 556.
    • (2001) Radiology , vol.221 , pp. 550-556
    • Hunsche, S.1    Moseley, M.E.2    Stoeter, P.3    Hedehus, M.4
  • 7
    • 0029402319 scopus 로고
    • Molecular diffusion, tissue microdynamics and microstructure
    • Le Bihan, D., 1995. Molecular diffusion, tissue microdynamics and microstructure. NMR Biomed. 8, 375- 386.
    • (1995) NMR Biomed , vol.8 , pp. 375-386
    • Le Bihan, D.1
  • 8
    • 10044240735 scopus 로고    scopus 로고
    • Self-navigated interleaved spiral (SNAILS): application to high-resolution diffusion tensor imaging
    • Liu, C., Bammer, R., Kim, D.H., Moseley, M.E., 2004. Self-navigated interleaved spiral (SNAILS): application to high-resolution diffusion tensor imaging. Magn. Reson. Med. 52, 1388- 1396.
    • (2004) Magn. Reson. Med. , vol.52 , pp. 1388-1396
    • Liu, C.1    Bammer, R.2    Kim, D.H.3    Moseley, M.E.4
  • 9
    • 25144471800 scopus 로고    scopus 로고
    • Investigations on the efficiency of cardiac-gated methods for the acquisition of diffusion-weighted images
    • Nunes, R.G., Jezzard, P., Clare, S., 2005. Investigations on the efficiency of cardiac-gated methods for the acquisition of diffusion-weighted images. J. Magn. Reson. Imaging 177, 102- 110.
    • (2005) J. Magn. Reson. Imaging , vol.177 , pp. 102-110
    • Nunes, R.G.1    Jezzard, P.2    Clare, S.3
  • 11
    • 0037229177 scopus 로고    scopus 로고
    • Reduction of eddy-current-induced distortion in diffusion MRI using a twicerefocused spin echo
    • Reese, T.G., Heid, O., Weisskoff, R.M., Wedeen, V.J., 2003. Reduction of eddy-current-induced distortion in diffusion MRI using a twicerefocused spin echo. Magn. Reson. Med. 49, 177- 182.
    • (2003) Magn. Reson. Med. , vol.49 , pp. 177-182
    • Reese, T.G.1    Heid, O.2    Weisskoff, R.M.3    Wedeen, V.J.4
  • 12
    • 0345742636 scopus 로고    scopus 로고
    • Comprehensive approach for correction of motion and distortion in diffusion-weighted MRI
    • Rohde, G.K., Barnett, A.S., Basser, P.J., Marenco, S., Pierpaoli, C., 2004. Comprehensive approach for correction of motion and distortion in diffusion-weighted MRI. Magn. Reson. Med. 51, 103- 114.
    • (2004) Magn. Reson. Med. , vol.51 , pp. 103-114
    • Rohde, G.K.1    Barnett, A.S.2    Basser, P.J.3    Marenco, S.4    Pierpaoli, C.5
  • 13
    • 4243148473 scopus 로고    scopus 로고
    • In vivo diffusion tensor imaging of human prostate
    • Sinha, S., Sinha, U., 2004. In vivo diffusion tensor imaging of human prostate. Magn. Reson. Med. 52, 530-537.
    • (2004) Magn. Reson. Med. , vol.52 , pp. 530-537
    • Sinha, S.1    Sinha, U.2
  • 14
    • 0038449816 scopus 로고    scopus 로고
    • Echo planar imaging at 4 Tesla with minimum acoustic noise
    • Tomasi, D.G., Ernst, T., 2003. Echo planar imaging at 4 Tesla with minimum acoustic noise. J. Magn. Reson. Imaging 18, 128-130.
    • (2003) J. Magn. Reson. Imaging , vol.18 , pp. 128-130
    • Tomasi, D.G.1    Ernst, T.2
  • 17
    • 0033772807 scopus 로고    scopus 로고
    • Gradient-induced acoustic and magnetic field fluctuations in a 4T whole-body MR imager
    • Wu, Y., Chronik, B.A., Bowen, C., Mechefske, C.K., Rutt, B.K., 2000. Gradient-induced acoustic and magnetic field fluctuations in a 4T whole-body MR imager. Magn. Reson. Med. 44, 532-536.
    • (2000) Magn. Reson. Med. , vol.44 , pp. 532-536
    • Wu, Y.1    Chronik, B.A.2    Bowen, C.3    Mechefske, C.K.4    Rutt, B.K.5
  • 18
    • 6344262132 scopus 로고    scopus 로고
    • Characterization of vibration and acoustic noise in a gradient-coil insert
    • Yao, G.Z., Mechefske, C.K., Rutt, B.K., 2004. Characterization of vibration and acoustic noise in a gradient-coil insert. MAGMA 17, 12- 27.
    • (2004) MAGMA , vol.17 , pp. 12-27
    • Yao, G.Z.1    Mechefske, C.K.2    Rutt, B.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.