Volumn 42, Issue 4, 2006, Pages 474-479
|
Detection of budesonide in human urine after inhalation by liquid chromatography-mass spectrometry
|
Author keywords
Budesonide; Corticosteroids; Doping; LC MS; Urine
|
Indexed keywords
16ALPHA HYDROXYPREDNISOLONE;
BUDESONIDE;
CORTICOSTEROID;
ACCURACY;
ARTICLE;
CONTROLLED STUDY;
DRUG DETERMINATION;
DRUG ISOLATION;
DRUG URINE LEVEL;
ELECTROSPRAY MASS SPECTROMETRY;
HUMAN;
HUMAN EXPERIMENT;
LIQUID CHROMATOGRAPHY;
LIQUID LIQUID EXTRACTION;
MALE;
METERED DOSE INHALER;
NORMAL HUMAN;
PRIORITY JOURNAL;
QUANTITATIVE ASSAY;
VALIDATION PROCESS;
ADMINISTRATION, INHALATION;
ADULT;
ANTI-INFLAMMATORY AGENTS;
BUDESONIDE;
CHROMATOGRAPHY, HIGH PRESSURE LIQUID;
HUMANS;
MALE;
METERED DOSE INHALERS;
PREDNISOLONE;
REPRODUCIBILITY OF RESULTS;
SPECTROMETRY, MASS, ELECTROSPRAY IONIZATION;
|
EID: 33748520232
PISSN: 07317085
EISSN: None
Source Type: Journal
DOI: 10.1016/j.jpba.2006.05.016 Document Type: Article |
Times cited : (32)
|
References (14)
|