메뉴 건너뛰기




Volumn 9, Issue 6, 2004, Pages 495-499

Theoretical analysis of chromatographic peak asymmetry and sharpness by the moment method using two peptides

Author keywords

Asymmetric factor; Excess; Moment analysis; Packings; Peptides; Skewness

Indexed keywords


EID: 33748494748     PISSN: 12268372     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02933492     Document Type: Article
Times cited : (14)

References (11)
  • 1
    • 0035964839 scopus 로고    scopus 로고
    • Application of a new mathematical function for describing chromatographic peaks
    • Pap, T. L. and Z. Papai (2001) Application of a new mathematical function for describing chromatographic peaks. J. Chromatogr. A 950: 55-60.
    • (2001) J. Chromatogr. A , vol.950 , pp. 55-60
    • Pap, T.L.1    Papai, Z.2
  • 2
    • 55449115201 scopus 로고    scopus 로고
    • Analysis of peak asymmetry in chromatography
    • Pápai, Zs. and T. L. Pap (2002) Analysis of peak asymmetry in chromatography. J. Chromatogr. A 955: 51-58.
    • (2002) J. Chromatogr. A , vol.955 , pp. 51-58
    • Pápai, Zs.1    Pap, T.L.2
  • 3
    • 0346155975 scopus 로고    scopus 로고
    • Optimum separation condition of peptides in reversed-phase liquid chromatography
    • Lee, S. K. and K. H. Row (2004) Optimum separation condition of peptides in reversed-phase liquid chromatography. J. Chromatogr. B 800: 115-120.
    • (2004) J. Chromatogr. B , vol.800 , pp. 115-120
    • Lee, S.K.1    Row, K.H.2
  • 4
    • 33644744896 scopus 로고    scopus 로고
    • New retention mechanism of mononucleotides with buffer concentrations in ion-suppressing RP-HPLC
    • Lee, J. W. and K. H. Row (2001) New retention mechanism of mononucleotides with buffer concentrations in ion-suppressing RP-HPLC. Biotechnol. Bioprocess Eng. 6: 57-41.
    • (2001) Biotechnol. Bioprocess Eng. , vol.6 , pp. 57-141
    • Lee, J.W.1    Row, K.H.2
  • 5
    • 0026881387 scopus 로고
    • Chromatography of liquid-phase adsorption on octadecylsily-silica gel
    • Miyabe, K. and M. Suzuki (1992) Chromatography of liquid-phase adsorption on octadecylsily-silica gel. AIChE J. 58:901-910.
    • (1992) AIChE J. , vol.58 , pp. 901-910
    • Miyabe, K.1    Suzuki, M.2
  • 6
    • 52349114479 scopus 로고    scopus 로고
    • Parameters estimation of perillyl alcohol in RP-HPLC by moment analysis
    • Row, K. H., C. H. Lee, and J. H. Kang (2002) Parameters estimation of perillyl alcohol in RP-HPLC by moment analysis. Biotechnol. Bioprocess Eng. 7: 16-20.
    • (2002) Biotechnol. Bioprocess Eng. , vol.7 , pp. 16-20
    • Row, K.H.1    Lee, C.H.2    Kang, J.H.3
  • 7
    • 0028460335 scopus 로고
    • Mass-transfer phenomena on the surface of adsorbent in reversed-phase chromatography
    • Miyabe, K. and M. Suzuki (1994) Mass-transfer phenomena on the surface of adsorbent in reversed-phase chromatography. Ind. Eng. Chem. Res. 55: 1792-1802.
    • (1994) Ind. Eng. Chem. Res. , vol.55 , pp. 1792-1802
    • Miyabe, K.1    Suzuki, M.2
  • 8
    • 0029256954 scopus 로고
    • Chromatographic study on liquid-phase adsorption on octadecylsilyl-silica gel
    • Miyabe, K. and M. Suzuki (1995) Chromatographic study on liquid-phase adsorption on octadecylsilyl-silica gel. AIChE J. 41: 548-558.
    • (1995) AIChE J. , vol.41 , pp. 548-558
    • Miyabe, K.1    Suzuki, M.2
  • 9
    • 0035876099 scopus 로고    scopus 로고
    • Retention and mass transfer characteristics in reversed-phase liquid chromatography using a tetrahydrofuran-water solution as the mobile phase
    • Kanji, M., S. Sayuri, and G. Georges (2001) Retention and mass transfer characteristics in reversed-phase liquid chromatography using a tetrahydrofuran-water solution as the mobile phase. J. Chromatogr. A 919: 251-244.
    • (2001) J. Chromatogr. A , vol.919 , pp. 251-1244
    • Kanji, M.1    Sayuri, S.2    Georges, G.3
  • 11
    • 0041345944 scopus 로고    scopus 로고
    • Efficiency of preparative and process column distribution systems
    • Gebauer, K. H., X. L. Luo, N. G. Barton, and A. N. Stokes (2005) Efficiency of preparative and process column distribution systems. J. Chromatogr. A 1006: 45-60.
    • (2005) J. Chromatogr. A , vol.1006 , pp. 45-60
    • Gebauer, K.H.1    Luo, X.L.2    Barton, N.G.3    Stokes, A.N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.