메뉴 건너뛰기




Volumn 5, Issue 1, 2006, Pages 86-89

Infected vertebroplasty requiring 360° spinal reconstruction: Long-term follow-up review - Report of two cases

Author keywords

Osteomyelitis; Surgical complication; Vertebroplasty

Indexed keywords

ANTIBIOTIC AGENT;

EID: 33748466549     PISSN: 15475654     EISSN: None     Source Type: Journal    
DOI: 10.3171/spi.2006.5.1.86     Document Type: Article
Times cited : (21)

References (18)
  • 1
    • 0035879117 scopus 로고    scopus 로고
    • The biomechanics of vertebroplasty: The effect of cement volume on mechanical behavior
    • Belkoff SM, Mathis JM, Jasper LE, Deramond H: The biomechanics of vertebroplasty: the effect of cement volume on mechanical behavior. Spine 26:1537-1541, 2001
    • (2001) Spine , vol.26 , pp. 1537-1541
    • Belkoff, S.M.1    Mathis, J.M.2    Jasper, L.E.3    Deramond, H.4
  • 3
    • 0029971187 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for osteolytic metastases and myeloma: Effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up
    • Cotten A, Dewatre F, Cortet B, Assaker R, Leblond D, Duquesnoy B, et al: Percutaneous vertebroplasty for osteolytic metastases and myeloma: effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up. Radiology 200:523-530, 1996
    • (1996) Radiology , vol.200 , pp. 523-530
    • Cotten, A.1    Dewatre, F.2    Cortet, B.3    Assaker, R.4    Leblond, D.5    Duquesnoy, B.6
  • 4
    • 0035879089 scopus 로고    scopus 로고
    • New technologies in spine: Kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures
    • Garfin SR, Yuan HA, Reiley MA: New technologies in spine: kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures. Spine 26:1511-1515, 2001
    • (2001) Spine , vol.26 , pp. 1511-1515
    • Garfin, S.R.1    Yuan, H.A.2    Reiley, M.A.3
  • 5
    • 0034918914 scopus 로고    scopus 로고
    • Major neurological complications following percutaneous vertebroplasty with polymethylmethacrylate. A case report
    • Harrington KD: Major neurological complications following percutaneous vertebroplasty with polymethylmethacrylate. A case report. J Bone Joint Surg Am 83:1070-1073, 2001
    • (2001) J Bone Joint Surg Am , vol.83 , pp. 1070-1073
    • Harrington, K.D.1
  • 6
    • 0031545893 scopus 로고    scopus 로고
    • Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: Technical aspects
    • Jensen ME, Evans AJ, Mathis JM, Kallmes DF, Cloft HJ, Dion JE: Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects. AJNR Am J Neuroradiol 18:1897-1904, 1997
    • (1997) AJNR Am J Neuroradiol , vol.18 , pp. 1897-1904
    • Jensen, M.E.1    Evans, A.J.2    Mathis, J.M.3    Kallmes, D.F.4    Cloft, H.J.5    Dion, J.E.6
  • 9
    • 0035879322 scopus 로고    scopus 로고
    • Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures
    • Lieberman IH, Dudeney S, Reinhardt MK, Bell G: Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures. Spine 26:1631-1638, 2001
    • (2001) Spine , vol.26 , pp. 1631-1638
    • Lieberman, I.H.1    Dudeney, S.2    Reinhardt, M.K.3    Bell, G.4
  • 10
    • 0010677426 scopus 로고    scopus 로고
    • Vertebroplasty: Techniques to avoid complications
    • Moreland DB, Landi MK, Grand W: Vertebroplasty: techniques to avoid complications. Spine J 1:66-71, 2001
    • (2001) Spine J , vol.1 , pp. 66-71
    • Moreland, D.B.1    Landi, M.K.2    Grand, W.3
  • 11
    • 0033824345 scopus 로고    scopus 로고
    • Vertebroplasty in patients with severe vertebral compression fractures: A technical report
    • O'Brien JP, Sims JT, Evans AJ: Vertebroplasty in patients with severe vertebral compression fractures: a technical report. AJNR Am J Neuroradiol 21:1555-1558, 2000
    • (2000) AJNR Am J Neuroradiol , vol.21 , pp. 1555-1558
    • O'Brien, J.P.1    Sims, J.T.2    Evans, A.J.3
  • 12
    • 25844435984 scopus 로고    scopus 로고
    • Single-stage debridement and instrumentation for pyogenic spinal infections
    • Ogden AT, Kaiser MG: Single-stage debridement and instrumentation for pyogenic spinal infections. Neurosurg Focus 17(6):E5, 2004
    • (2004) Neurosurg Focus , vol.17 , Issue.6
    • Ogden, A.T.1    Kaiser, M.G.2
  • 13
    • 0033366518 scopus 로고    scopus 로고
    • Pulmonary embolism caused by acrylic cement: A rare complication of percutaneous vertebroplasty
    • Padovani B, Kasriel O, Brunner P, Peretti-Viton P: Pulmonary embolism caused by acrylic cement: a rare complication of percutaneous vertebroplasty. AJNR Am J Neuroradiol 20:375-377, 1999
    • (1999) AJNR Am J Neuroradiol , vol.20 , pp. 375-377
    • Padovani, B.1    Kasriel, O.2    Brunner, P.3    Peretti-Viton, P.4
  • 14
    • 0037102557 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty: New treatment for vertebral compression fractures
    • Predey TA, Sewall LE, Smith SJ: Percutaneous vertebroplasty: new treatment for vertebral compression fractures. Am Fam Physician 66:611-615, 2002
    • (2002) Am Fam Physician , vol.66 , pp. 611-615
    • Predey, T.A.1    Sewall, L.E.2    Smith, S.J.3
  • 15
    • 18044402604 scopus 로고    scopus 로고
    • Root and spinal cord compression from methylmethacrylate vertebroplasty
    • Ratliff J, Nguyen T, Heiss J: Root and spinal cord compression from methylmethacrylate vertebroplasty. Spine 26:E300-E302, 2001
    • (2001) Spine , vol.26
    • Ratliff, J.1    Nguyen, T.2    Heiss, J.3
  • 16
    • 0033200346 scopus 로고    scopus 로고
    • Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures
    • Tohmeh AG, Mathis JM, Fenton DC, Levine AM, Belkoff SM: Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures. Spine 24:1772-1776, 1999
    • (1999) Spine , vol.24 , pp. 1772-1776
    • Tohmeh, A.G.1    Mathis, J.M.2    Fenton, D.C.3    Levine, A.M.4    Belkoff, S.M.5
  • 17
    • 0642281043 scopus 로고    scopus 로고
    • Antibiotic-loaded cement in revision joint replacement
    • Youngman JR, Ridgway GL, Haddad FS: Antibiotic-loaded cement in revision joint replacement. Hosp Med 64:613-616, 2003
    • (2003) Hosp Med , vol.64 , pp. 613-616
    • Youngman, J.R.1    Ridgway, G.L.2    Haddad, F.S.3
  • 18
    • 3543086793 scopus 로고    scopus 로고
    • Serious pyogenic spondylitis following vertebroplasty - a case report
    • Yu Sw, Chen WJ, Lin WC, Chen YJ, Tu YK: Serious pyogenic spondylitis following vertebroplasty - a case report. Spine 29:E209-E211, 2004
    • (2004) Spine , vol.29
    • Yu, S.1    Chen, W.J.2    Lin, W.C.3    Chen, Y.J.4    Tu, Y.K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.