메뉴 건너뛰기




Volumn 35, Issue 1, 2006, Pages 33-41

In vitro testing of platelets using the thromboelastogram, platelet function analyzer, and the clot signature analyzer to predict the bleeding time

Author keywords

Bleeding time; Clot signature analyzer; Platelet function analyzer; Thromboelastogram

Indexed keywords

APHERESIS; ARTICLE; BLEEDING TIME; BLOOD ANALYSIS; BLOOD CLOT LYSIS; BLOOD CLOTTING; CLOT SIGNATURE ANALYZER; CONTROLLED STUDY; CORRELATION ANALYSIS; CORRELATION COEFFICIENT; ERYTHROCYTE; FEMALE; HEMATOCRIT; HEMOSTASIS; HUMAN; MALE; NORMAL HUMAN; PLATELET FUNCTION ANALYZER; THROMBOELASTOGRAPHY;

EID: 33748465572     PISSN: 14730502     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.transci.2006.02.003     Document Type: Article
Times cited : (7)

References (23)
  • 1
    • 0028031929 scopus 로고
    • In vitro assessment of the quality of stored platelet concentrates. The BEST (Biomedical Excellence for Safer Transfusion) Task Force of the International Society of Blood Transfusion
    • Murphy S., Rebulla P., Bertolini F., et al. In vitro assessment of the quality of stored platelet concentrates. The BEST (Biomedical Excellence for Safer Transfusion) Task Force of the International Society of Blood Transfusion. Transfus Med Rev 8 (1994) 29-36
    • (1994) Transfus Med Rev , vol.8 , pp. 29-36
    • Murphy, S.1    Rebulla, P.2    Bertolini, F.3
  • 2
    • 0016246832 scopus 로고
    • The relation between response to hypotonic stress and the 51Cr recovery in vivo of preserved platelets
    • Valeri C.R., Feingold H., and Marchionni L.D. The relation between response to hypotonic stress and the 51Cr recovery in vivo of preserved platelets. Transfusion 4 (1974) 331-337
    • (1974) Transfusion , vol.4 , pp. 331-337
    • Valeri, C.R.1    Feingold, H.2    Marchionni, L.D.3
  • 3
    • 0032919481 scopus 로고    scopus 로고
    • Comparison of the effects of transfusions of cryopreserved and liquid-preserved platelets on hemostasis and blood loss after cardiopulmonary bypass
    • Khuri S.F., Healey N., MacGregor H., Barnard M.R., Szymanski I.O., Birjiniuk V., et al. Comparison of the effects of transfusions of cryopreserved and liquid-preserved platelets on hemostasis and blood loss after cardiopulmonary bypass. J Thorac Cardiovasc Surg 117 (1999) 172-184
    • (1999) J Thorac Cardiovasc Surg , vol.117 , pp. 172-184
    • Khuri, S.F.1    Healey, N.2    MacGregor, H.3    Barnard, M.R.4    Szymanski, I.O.5    Birjiniuk, V.6
  • 4
    • 0033364533 scopus 로고    scopus 로고
    • Fresh, liquid-preserved, and cryopreserved platelets: adhesive surface receptors and membrane procoagulant activity
    • Barnard M.R., MacGregor H., Ragno G., Pivacek L.E., Khuri S.F., Michelson A.D., et al. Fresh, liquid-preserved, and cryopreserved platelets: adhesive surface receptors and membrane procoagulant activity. Transfusion 39 (1999) 880-888
    • (1999) Transfusion , vol.39 , pp. 880-888
    • Barnard, M.R.1    MacGregor, H.2    Ragno, G.3    Pivacek, L.E.4    Khuri, S.F.5    Michelson, A.D.6
  • 5
    • 11144354139 scopus 로고    scopus 로고
    • Evaluation of stored platelets
    • International Forum. Evaluation of stored platelets. Vox Sang 86 (2004) 203-223
    • (2004) Vox Sang , vol.86 , pp. 203-223
    • International Forum1
  • 6
    • 0015525988 scopus 로고
    • The bleeding time as a screening test for the evaluation of platelet function
    • Harker L.A., and Slichter S.J. The bleeding time as a screening test for the evaluation of platelet function. N Engl J Med 287 (1972) 155-159
    • (1972) N Engl J Med , vol.287 , pp. 155-159
    • Harker, L.A.1    Slichter, S.J.2
  • 7
    • 0024391179 scopus 로고
    • A reassessment of the bleeding time: association of age, hematocrit, platelet function, von Willebrand factor, and bleeding time thromboxane B2 with the length of the bleeding time
    • Gerrard J.M., Docherty J.C., Israels S.J., et al. A reassessment of the bleeding time: association of age, hematocrit, platelet function, von Willebrand factor, and bleeding time thromboxane B2 with the length of the bleeding time. Clin Invest Med 12 (1989) 165-171
    • (1989) Clin Invest Med , vol.12 , pp. 165-171
    • Gerrard, J.M.1    Docherty, J.C.2    Israels, S.J.3
  • 8
    • 0028949673 scopus 로고
    • Effects of temperature on bleeding time and clotting time in normal male and female volunteers
    • Valeri C.R., MacGregor H., Cassidy G., Tinney R., and Pompei F. Effects of temperature on bleeding time and clotting time in normal male and female volunteers. Crit Care Med 23 (1995) 698-704
    • (1995) Crit Care Med , vol.23 , pp. 698-704
    • Valeri, C.R.1    MacGregor, H.2    Cassidy, G.3    Tinney, R.4    Pompei, F.5
  • 9
    • 0030711743 scopus 로고    scopus 로고
    • The volume of blood shed during the bleeding time correlates with the peripheral venous hematocrit
    • Crowley J.P., Metzger J.B., and Valeri C.R. The volume of blood shed during the bleeding time correlates with the peripheral venous hematocrit. Am J Clin Path 108 (1997) 579-584
    • (1997) Am J Clin Path , vol.108 , pp. 579-584
    • Crowley, J.P.1    Metzger, J.B.2    Valeri, C.R.3
  • 10
    • 0031820606 scopus 로고    scopus 로고
    • The red cell transfusion trigger: has a sin of commission now become a sin of omission?
    • Valeri C.R., Crowley J.P., and Loscalzo J. The red cell transfusion trigger: has a sin of commission now become a sin of omission?. Transfusion 38 (1998) 602-610
    • (1998) Transfusion , vol.38 , pp. 602-610
    • Valeri, C.R.1    Crowley, J.P.2    Loscalzo, J.3
  • 11
    • 0029422608 scopus 로고
    • The thromboelastograph and the thromboelastograph technique
    • Chandler W.L. The thromboelastograph and the thromboelastograph technique. Semin Thromb Hemost 21 (1995) 1-6
    • (1995) Semin Thromb Hemost , vol.21 , pp. 1-6
    • Chandler, W.L.1
  • 12
    • 0029583751 scopus 로고
    • Thromboelastographic modifications induced by intra-venous and subcutaneous heparin administration
    • Traverso C.I., Caprini J.A., Arcelus J., and Arcelus I.M. Thromboelastographic modifications induced by intra-venous and subcutaneous heparin administration. Semin Thromb Hemost 21 (1995) 53-58
    • (1995) Semin Thromb Hemost , vol.21 , pp. 53-58
    • Traverso, C.I.1    Caprini, J.A.2    Arcelus, J.3    Arcelus, I.M.4
  • 13
    • 0029587243 scopus 로고
    • Thromboelastographic study of fibrinolytic agents
    • Summaria L. Thromboelastographic study of fibrinolytic agents. Semin Thromb Hemost 21 (1995) 63-71
    • (1995) Semin Thromb Hemost , vol.21 , pp. 63-71
    • Summaria, L.1
  • 14
    • 4043117617 scopus 로고    scopus 로고
    • The in vitro effects of poly-N-acetylglucosamine on the activation of platelets in platelet-rich plasma with and without red blood cells
    • Valeri C.R., Srey R., Tilahun D., and Ragno G. The in vitro effects of poly-N-acetylglucosamine on the activation of platelets in platelet-rich plasma with and without red blood cells. J Trauma (Suppl) 57 (2004) 522-525
    • (2004) J Trauma (Suppl) , vol.57 , pp. 522-525
    • Valeri, C.R.1    Srey, R.2    Tilahun, D.3    Ragno, G.4
  • 17
    • 0025166288 scopus 로고
    • A critical reappraisal of the bleeding time
    • Rodgers R.P.C., and Levin J. A critical reappraisal of the bleeding time. Semin Thromb Hemost 16 (1991) 1-20
    • (1991) Semin Thromb Hemost , vol.16 , pp. 1-20
    • Rodgers, R.P.C.1    Levin, J.2
  • 18
    • 0025768028 scopus 로고
    • The bleeding time does not predict surgical bleeding
    • Lind S.E. The bleeding time does not predict surgical bleeding. Blood 77 (1991) 2547-2552
    • (1991) Blood , vol.77 , pp. 2547-2552
    • Lind, S.E.1
  • 19
    • 0026689814 scopus 로고
    • Hematologic changes during and after cardiopulmonary bypass and their relationship to the bleeding time and nonsurgical blood loss
    • Khuri S.F., Wolfe J.A., Josa M., Axford T.C., Szymanski I.O., Assousa S.N., et al. Hematologic changes during and after cardiopulmonary bypass and their relationship to the bleeding time and nonsurgical blood loss. J Thorac Cardiovasc Surg 104 (1992) 94-107
    • (1992) J Thorac Cardiovasc Surg , vol.104 , pp. 94-107
    • Khuri, S.F.1    Wolfe, J.A.2    Josa, M.3    Axford, T.C.4    Szymanski, I.O.5    Assousa, S.N.6
  • 20
    • 0043119631 scopus 로고    scopus 로고
    • Bleeding during and after cardiopulmonary bypass: a 15-year institutional experience
    • Pifarre R. (Ed), Hanley & Belfus, Philadelphia [Chapter 8]
    • Khuri S.F., Valeri C.R., and Treanor P. Bleeding during and after cardiopulmonary bypass: a 15-year institutional experience. In: Pifarre R. (Ed). Management of bleeding in cardiovascular surgery (2000), Hanley & Belfus, Philadelphia 145-160 [Chapter 8]
    • (2000) Management of bleeding in cardiovascular surgery , pp. 145-160
    • Khuri, S.F.1    Valeri, C.R.2    Treanor, P.3
  • 21
    • 0018123667 scopus 로고
    • Development and evaluation of a disposable device for performing simultaneous duplicate bleeding time determinations
    • Babson S.R., and Babson A.L. Development and evaluation of a disposable device for performing simultaneous duplicate bleeding time determinations. Am J Clin Pathol 70 (1978) 406-408
    • (1978) Am J Clin Pathol , vol.70 , pp. 406-408
    • Babson, S.R.1    Babson, A.L.2
  • 23
    • 0035431030 scopus 로고    scopus 로고
    • Anemia-induced increase in the bleeding time: implications for treatment of non-surgical blood loss
    • Valeri C.R., Cassidy G., Pivacek L.E., Ragno G., Lieberthal W., Crowley J.P., et al. Anemia-induced increase in the bleeding time: implications for treatment of non-surgical blood loss. Transfusion 41 (2001) 977-983
    • (2001) Transfusion , vol.41 , pp. 977-983
    • Valeri, C.R.1    Cassidy, G.2    Pivacek, L.E.3    Ragno, G.4    Lieberthal, W.5    Crowley, J.P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.