메뉴 건너뛰기




Volumn 26, Issue 1, 2006, Pages 65-69

Application of revised best square approach algorithm in power systems

Author keywords

Aperiodic component; Periodic component; Power system; The best square approach algorithm

Indexed keywords

ALGORITHMS; CALCULATIONS; COMPUTER SIMULATION; LEAST SQUARES APPROXIMATIONS; MATRIX ALGEBRA;

EID: 33748457307     PISSN: 10066047     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (8)
  • 1
    • 26844549938 scopus 로고
    • Application of recursive least square algorithm in distance relaying
    • ZHANG Zhe, CHEN De-shu. Application of recursive least square algorithm in distance relaying[J]. Automation of Electric Power Systems, 1991, 15(4): 31-40.
    • (1991) Automation of Electric Power Systems , vol.15 , Issue.4 , pp. 31-40
    • Zhang, Z.1    Chen, D.-S.2
  • 2
    • 4243186233 scopus 로고    scopus 로고
    • Comparison of load models using artificial neural networks and recursive least-squares identification
    • QIU Xiao-yan, LI Xing-yuan, SONG Yong-hua, et al. Comparison of load models using artificial neural networks and recursive least-squares identification[J]. Automation of Electric Power Systems, 1996, 20(5): 29-33.
    • (1996) Automation of Electric Power Systems , vol.20 , Issue.5 , pp. 29-33
    • Qiu, X.-Y.1    Li, X.-Y.2    Song, Y.-H.3
  • 3
    • 33748456811 scopus 로고    scopus 로고
    • The weighted least squares method with optimal weight for linear dependent equation of power consumption forecast
    • LIU Min-hua. The weighted least squares method with optimal weight for linear dependent equation of power consumption forecast[J]. J. of Xuzhou Normal Uni.: Natural Sciences, 2003, 21(3): 26-29.
    • (2003) J. of Xuzhou Normal Uni.: Natural Sciences , vol.21 , Issue.3 , pp. 26-29
    • Liu, M.-H.1
  • 4
    • 0037570867 scopus 로고    scopus 로고
    • A compact algorithm for filtering decaying DC component in relay protection Fourier algorithm
    • HUANG Kai, SUN Ling-sheng. A compact algorithm for filtering decaying DC component in relay protection Fourier algorithm[J]. Automation of Electric Power Systems, 2003, 27(4): 50-52.
    • (2003) Automation of Electric Power Systems , vol.27 , Issue.4 , pp. 50-52
    • Huang, K.1    Sun, L.-S.2
  • 5
    • 33748465026 scopus 로고    scopus 로고
    • An efficient method to eliminate the effects of decaying DC component on the least square algorithm
    • ZHOU Da-min, LONG Yan. An efficient method to eliminate the effects of decaying DC component on the least square algorithm[J]. Power System Technology, 1999, 23(3): 31-34.
    • (1999) Power System Technology , vol.23 , Issue.3 , pp. 31-34
    • Zhou, D.-M.1    Long, Y.2
  • 6
    • 33748441476 scopus 로고    scopus 로고
    • Comparison between two restraint criteria of the magnetizing inrush and harmonic
    • QIU Wen-zheng, CHEN De-shu. Comparison between two restraint criteria of the magnetizing inrush and harmonic[J]. Electric Power Automation Equipment, 1998, 18(3): 8-10.
    • (1998) Electric Power Automation Equipment , vol.18 , Issue.3 , pp. 8-10
    • Qiu, W.-Z.1    Chen, D.-S.2
  • 7
    • 33748445009 scopus 로고    scopus 로고
    • Discussion on the setting calculations of stator ground protection based on the third harmonic voltage criterion
    • GUO Ai-jun. Discussion on the setting calculations of stator ground protection based on the third harmonic voltage criterion[J]. Relay, 2004, 32(3): 32-38.
    • (2004) Relay , vol.32 , Issue.3 , pp. 32-38
    • Guo, A.-J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.