Improved perfusion system for bipolar radiofrequency ablation of liver: Preliminary findings from a computer modeling study

Author keywords

Computer model; Finite element method; Hepatic ablation; Numerical model; Perfusion electrode; Radiofrequency ablation; Saline perfusion; Theoretical model; Thermoablation

Indexed keywords

COAGULATION; ELECTRODES; FINITE ELEMENT METHOD; NUMERICAL METHODS; TUMORS;

EID: 33748426673     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/27/10/N03     Document Type: Article
Times cited : (25)

References (28)
  • 1
    • 33646556653 scopus 로고    scopus 로고
    • Theoretical modeling for radiofrequency ablation: State-of-the-art and challenges for the future
    • Berjano E J 2006 Theoretical modeling for radiofrequency ablation: state-of-the-art and challenges for the future Biomed. Eng. Online. 5 24
    • (2006) Biomed. Eng. Online. , vol.5 , Issue.1 , pp. 24
    • Berjano, E.J.1
  • 2
    • 23844436063 scopus 로고    scopus 로고
    • Modeling for radio-frequency conductive keratoplasty: Implications for the maximum temperature reached in the cornea
    • Berjano E J, Alio J L and Saiz J 2005 Modeling for radio-frequency conductive keratoplasty: implications for the maximum temperature reached in the cornea Physiol. Meas. 26 157-72
    • (2005) Physiol. Meas. , vol.26 , Issue.3 , pp. 157-172
    • Berjano, E.J.1    Alio, J.L.2    Saiz, J.3
  • 3
    • 3242669886 scopus 로고    scopus 로고
    • Thermal-electrical modeling for epicardial atrial radiofrequency ablation
    • Berjano E J and Hornero F 2004 Thermal-electrical modeling for epicardial atrial radiofrequency ablation IEEE Trans. Biomed. Eng. 51 1348-57
    • (2004) IEEE Trans. Biomed. Eng. , vol.51 , Issue.8 , pp. 1348-1357
    • Berjano, E.J.1    Hornero, F.2
  • 4
    • 0042262536 scopus 로고    scopus 로고
    • Temperature dependence of thermal conductivity of biological tissues
    • Bhattacharya A and Mahajan R L 2003 Temperature dependence of thermal conductivity of biological tissues Physiol. Meas. 24 769-83
    • (2003) Physiol. Meas. , vol.24 , Issue.3 , pp. 769-783
    • Bhattacharya, A.1    Mahajan, R.L.2
  • 5
    • 0036190130 scopus 로고    scopus 로고
    • Radio-frequency tumor ablation: Internally cooled electrode versus saline-enhanced technique in an aggressive rabbit tumor model
    • Boehm T, Malich A, Goldberg S N, Reichenbach J R, Hilger I, Hauff P, Reinhardt M, Fleck M and Kaiser W A 2002 Radio-frequency tumor ablation: internally cooled electrode versus saline-enhanced technique in an aggressive rabbit tumor model Radiology 222 805-13
    • (2002) Radiology , vol.222 , Issue.3 , pp. 805-813
    • Boehm, T.1    Malich, A.2    Goldberg, S.N.3    Reichenbach, J.R.4    Hilger, I.5    Hauff, P.6    Reinhardt, M.7    Fleck, M.8    Kaiser, W.A.9
  • 7
    • 0344406953 scopus 로고    scopus 로고
    • Large hepatic ablation with bipolar saline-enhanced radiofrequency: An experimental study in in vivo porcine liver with a novel approach
    • Burdio F, Guemes A, Burdio J M, Navarro A, Sousa R, Castiella T, Cruz I, Burzaco O, Guirao X and Lozano R 2003a Large hepatic ablation with bipolar saline-enhanced radiofrequency: an experimental study in in vivo porcine liver with a novel approach J. Surg. Res. 110 193-201
    • (2003) J. Surg. Res. , vol.110 , Issue.1 , pp. 193-201
    • Burdio, F.1    Guemes, A.2    Burdio, J.M.3    Navarro, A.4    Sousa, R.5    Castiella, T.6    Cruz, I.7    Burzaco, O.8    Guirao, X.9    Lozano, R.10
  • 8
    • 0142147989 scopus 로고    scopus 로고
    • Bipolar saline-enhanced electrode for radiofrequency ablation: Results of experimental study of in vivo porcine liver
    • Burdio F, Guemes A, Burdio J M, Navarro A, Sousa R, Castiella T, Cruz I, Burzaco O and Lozano R 2003b Bipolar saline-enhanced electrode for radiofrequency ablation: results of experimental study of in vivo porcine liver Radiology 229 447-56
    • (2003) Radiology , vol.229 , Issue.2 , pp. 447-456
    • Burdio, F.1    Guemes, A.2    Burdio, J.M.3    Navarro, A.4    Sousa, R.5    Castiella, T.6    Cruz, I.7    Burzaco, O.8    Lozano, R.9
  • 10
    • 22144469863 scopus 로고    scopus 로고
    • Premature roll-off in radiofrequency ablation using bipolar saline-enhanced electrodes
    • Burdio F, Navarro A, Sousa R, Guemes A, Burdio J M, Tejero E and Lozano R 2005 Premature roll-off in radiofrequency ablation using bipolar saline-enhanced electrodes Eur. Radiol. 15 1495-6
    • (2005) Eur. Radiol. , vol.15 , Issue.7 , pp. 1495-1496
    • Burdio, F.1    Navarro, A.2    Sousa, R.3    Guemes, A.4    Burdio, J.M.5    Tejero, E.6    Lozano, R.7
  • 11
    • 1942533893 scopus 로고    scopus 로고
    • Finite element analysis of hepatic radiofrequency ablation probes using temperature-dependent electrical conductivity
    • Chang I 2003 Finite element analysis of hepatic radiofrequency ablation probes using temperature-dependent electrical conductivity Biomed. Eng. Online 2 12
    • (2003) Biomed. Eng. Online , vol.2 , Issue.1 , pp. 12
    • Chang, I.1
  • 12
    • 0042662575 scopus 로고    scopus 로고
    • Radiofrequency ablation of malignant liver tumors
    • Curley S A 2003 Radiofrequency ablation of malignant liver tumors Ann. Surg. Oncol. 10 338-347
    • (2003) Ann. Surg. Oncol. , vol.10 , Issue.4 , pp. 338-347
    • Curley, S.A.1
  • 13
    • 24044533231 scopus 로고    scopus 로고
    • CT mapping of the distribution of saline during radiofrequency ablation with perfusion electrodes
    • Gillams A R and Lees W R 2005 CT mapping of the distribution of saline during radiofrequency ablation with perfusion electrodes Cardiovasc. Intervent. Radiol. 28 476-80
    • (2005) Cardiovasc. Intervent. Radiol. , vol.28 , Issue.4 , pp. 476-480
    • Gillams, A.R.1    Lees, W.R.2
  • 15
    • 0038519127 scopus 로고    scopus 로고
    • Hepatic bipolar radiofrequency ablation creates coagulation zones close to blood vessels: A finite element study
    • Haemmerich D, Wright A W, Mahvi D M, Lee F T Jr and Webster J G 2003 Hepatic bipolar radiofrequency ablation creates coagulation zones close to blood vessels: a finite element study Med. Biol. Eng. Comput. 41 317-23
    • (2003) Med. Biol. Eng. Comput. , vol.41 , Issue.3 , pp. 317-323
    • Haemmerich, D.1    Wright, A.W.2    Mahvi, D.M.3    Lee, F.T.4    Webster, J.G.5
  • 18
    • 10044296989 scopus 로고    scopus 로고
    • Hepatic bipolar radiofrequency ablation using perfused-cooled electrodes: A comparative study in the ex vivo bovine liver
    • Lee J M, Han J K, Kim S H, Lee J Y, Choi S H and Choi B I 2004 Hepatic bipolar radiofrequency ablation using perfused-cooled electrodes: a comparative study in the ex vivo bovine liver Br. J. Radiol. 77 944-9
    • (2004) Br. J. Radiol. , vol.77 , Issue.923 , pp. 944-949
    • Lee, J.M.1    Han, J.K.2    Kim, S.H.3    Lee, J.Y.4    Choi, S.H.5    Choi, B.I.6
  • 19
    • 17044427608 scopus 로고    scopus 로고
    • Bipolar radiofrequency ablation in ex vivo bovine liver with the open-perfused system versus the cooled-wet system
    • Lee J M, Han J K, Kim S H, Sohn K L, Choi S H and Choi B I 2005 Bipolar radiofrequency ablation in ex vivo bovine liver with the open-perfused system versus the cooled-wet system Eur. Radiol. 15 759-64
    • (2005) Eur. Radiol. , vol.15 , Issue.4 , pp. 759-764
    • Lee, J.M.1    Han, J.K.2    Kim, S.H.3    Sohn, K.L.4    Choi, S.H.5    Choi, B.I.6
  • 21
    • 0030686445 scopus 로고    scopus 로고
    • Nonuniform heating during radiofrequency catheter ablation with long electrodes: Monitoring the edge effect
    • McRury I D, Panescu D, Mitchell M A and Haines D E 1997 Nonuniform heating during radiofrequency catheter ablation with long electrodes: monitoring the edge effect Circulation 96 4057-64
    • (1997) Circulation , vol.96 , pp. 4057-4064
    • McRury, I.D.1    Panescu, D.2    Mitchell, M.A.3    Haines, D.E.4
  • 22
    • 0034053049 scopus 로고    scopus 로고
    • Treatment of VX2 liver tumor in rabbits with 'wet' electrode mediated radio-frequency ablation
    • Miao Y, Ni Y, Mulier S, Yu J, De Weber I, Penninckx F, Baert A L and Marchal G 2000 Treatment of VX2 liver tumor in rabbits with 'wet' electrode mediated radio-frequency ablation Eur. Radiol. 10 188-194
    • (2000) Eur. Radiol. , vol.10 , Issue.1 , pp. 188-194
    • Miao, Y.1    Ni, Y.2    Mulier, S.3    Yu, J.4    De Weber, I.5    Penninckx, F.6    Baert, A.L.7    Marchal, G.8
  • 24
    • 0042977261 scopus 로고    scopus 로고
    • Changes in dielectric properties at 460 kHz of kidney and fat during heating: Importance for radio-frequency thermal therapy
    • Pop M, Molckovsky A, Chin L, Kolios M C, Jewett M A and Sherar M D 2003 Changes in dielectric properties at 460 kHz of kidney and fat during heating: importance for radio-frequency thermal therapy Phys. Med. Biol. 48 2509-25
    • (2003) Phys. Med. Biol. , vol.48 , Issue.15 , pp. 2509-2525
    • Pop, M.1    Molckovsky, A.2    Chin, L.3    Kolios, M.C.4    Jewett, M.A.5    Sherar, M.D.6
  • 25
    • 0024433306 scopus 로고
    • Determinants of impedance rise during catheter ablation of bovine myocardium with radiofrequency energy
    • Ring M E, Huang S K, Gorman G and Graham A R 1989 Determinants of impedance rise during catheter ablation of bovine myocardium with radiofrequency energy Pacing Clin. Electrophysiol. 12 1502-13
    • (1989) Pacing Clin. Electrophysiol. , vol.12 , Issue.9 , pp. 1502-1513
    • Ring, M.E.1    Huang, S.K.2    Gorman, G.3    Graham, A.R.4
  • 26
    • 22544465241 scopus 로고    scopus 로고
    • Radiofrequency ablation: Importance of background tissue electrical conductivity-an agar phantom and computer modeling study
    • Solazzo S A, Liu Z, Lobo S M, Ahmed M, Hines-Peralta A U, Lenkinski R E and Goldberg S N 2005 Radiofrequency ablation: importance of background tissue electrical conductivity-an agar phantom and computer modeling study Radiology 236 495-502
    • (2005) Radiology , vol.236 , Issue.2 , pp. 495-502
    • Solazzo, S.A.1    Liu, Z.2    Lobo, S.M.3    Ahmed, M.4    Hines-Peralta, A.U.5    Lenkinski, R.E.6    Goldberg, S.N.7
  • 27
    • 3142715930 scopus 로고    scopus 로고
    • Variability of size and shape of necrosis induced by radiofrequency ablation in human livers: A volumetric evaluation
    • Stippel D L, Brochhagen H G, Arenja M, Hunkemoller J, Holscher A H and Beckurts K T 2004 Variability of size and shape of necrosis induced by radiofrequency ablation in human livers: a volumetric evaluation Ann. Surg. Oncol. 11 420-5
    • (2004) Ann. Surg. Oncol. , vol.11 , Issue.4 , pp. 420-425
    • Stippel, D.L.1    Brochhagen, H.G.2    Arenja, M.3    Hunkemoller, J.4    Holscher, A.H.5    Beckurts, K.T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.