메뉴 건너뛰기




Volumn 27, Issue 10, 2006, Pages 999-1008

Does centripetal acceleration affect trunk flexion monitoring by means of accelerometers?

Author keywords

3D rigid body position and orientation; Accelerometer; Gyroscopes; Human movement analysis; Long term monitoring; Patient monitoring; Posturography; Short term monitoring; Simulation

Indexed keywords

ACCELEROMETERS; ERRORS; NANOSENSORS; PATIENT MONITORING; WEARABLE SENSORS;

EID: 33748425913     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/27/10/006     Document Type: Article
Times cited : (15)

References (18)
  • 1
    • 33745137544 scopus 로고
    • Cappozzo A 1982 Head and trunk mechanics in level walking PhD Thesis University of Strathclyde, Glasgow, UK
    • (1982) PhD Thesis
    • Cappozzo, A.1
  • 7
    • 23744509825 scopus 로고    scopus 로고
    • Comparison of three different kinematic sensors assemblies for the locomotion study
    • Giansanti D and Maccioni G 2005 Comparison of three different kinematic sensors assemblies for the locomotion study Physiol. Meas. 26 689-705
    • (2005) Physiol. Meas. , vol.26 , Issue.5 , pp. 689-705
    • Giansanti, D.1    MacCioni, G.2
  • 8
    • 33745122501 scopus 로고    scopus 로고
    • Physiological motion monitoring: Wearable device and adaptative algorithm for sit-to-stand timing detection
    • Giansanti D and Maccioni G 2006 Physiological motion monitoring: wearable device and adaptative algorithm for sit-to-stand timing detection Physiol. Meas. 27 713-23
    • (2006) Physiol. Meas. , vol.27 , Issue.8 , pp. 713-723
    • Giansanti, D.1    MacCioni, G.2
  • 9
    • 21844473021 scopus 로고    scopus 로고
    • The development and test of a DEVICE for the reconstruction of 3D position and orientation by means of a kinematic sensor assembly with rate gyroscopes and accelerometers
    • Giansanti D, Maccioni G and Macellari V 2005 The development and test of a DEVICE for the reconstruction of 3D position and orientation by means of a kinematic sensor assembly with rate gyroscopes and accelerometers IEEE Trans. Biomed. Eng. 52 1271-7
    • (2005) IEEE Trans. Biomed. Eng. , vol.52 , Issue.7 , pp. 1271-1277
    • Giansanti, D.1    MacCioni, G.2    MacEllari, V.3
  • 10
    • 0037389292 scopus 로고    scopus 로고
    • Is it feasible to reconstruct body segment 3-D position and orientation using accelerometric data?
    • Giansanti D, Macellari V, Maccioni G and Cappozzo A 2003 Is it feasible to reconstruct body segment 3-D position and orientation using accelerometric data? IEEE Trans. Biomed. 50 476-83
    • (2003) IEEE Trans. Biomed. , vol.50 , Issue.4 , pp. 476-483
    • Giansanti, D.1    MacEllari, V.2    MacCioni, G.3    Cappozzo, A.4
  • 12
  • 13
    • 2342539792 scopus 로고    scopus 로고
    • Accelerometry: Providing an integrated, practical method for long-term, ambulatory monitoring of human movement
    • Mathie M J, Coster A C F, Lovell N H and Celler B G 2004 Accelerometry: providing an integrated, practical method for long-term, ambulatory monitoring of human movement Physiol. Meas. 25 R1-R20
    • (2004) Physiol. Meas. , vol.25 , Issue.2
    • Mathie, M.J.1    Coster, A.C.F.2    Lovell, N.H.3    Celler, B.G.4
  • 15
    • 0036063718 scopus 로고    scopus 로고
    • Trunk accelerometry as a measure of balance control during quiet standing
    • Moe-Nilssen R and Helbostad J L 2002 Trunk accelerometry as a measure of balance control during quiet standing Gait Posture 16 60-68
    • (2002) Gait Posture , vol.16 , Issue.1 , pp. 60-68
    • Moe-Nilssen, R.1    Helbostad, J.L.2
  • 17
    • 0030463516 scopus 로고    scopus 로고
    • Detection of static and dynamic activity using uniaxial accelerometers
    • Veltink P H and Bussmann H B J 1996 Detection of static and dynamic activity using uniaxial accelerometers IEEE Trans. Rehab. Eng. 4 375-385
    • (1996) IEEE Trans. Rehab. Eng. , vol.4 , Issue.4 , pp. 375-385
    • Veltink, P.H.1    Bussmann, H.B.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.