메뉴 건너뛰기




Volumn 26, Issue 3, 2006, Pages 353-359

Improvement of peritoneal ultrafiltration with peritoneal dialysis solution buffered with bicarbonate/lactate mixture

Author keywords

Bicarbonate; Glucose degradation products; Lactate; pH; Solute transport; Ultrafiltration

Indexed keywords

ALBUMIN I 125; BICARBONATE; BUFFER; CALCIUM CHLORIDE; CREATININE; GAMBROSOL TRIO; GLUCOSE; GLUCOSE DEGRADATION PRODUCT; LACTIC ACID; MAGNESIUM CHLORIDE; NEUTRAL; PD BIO; PERITONEAL DIALYSIS FLUID; PHOSPHATE; SODIUM CHLORIDE; UREA;

EID: 33748422221     PISSN: 08968608     EISSN: None     Source Type: Journal    
DOI: 10.1177/089686080602600313     Document Type: Article
Times cited : (37)

References (21)
  • 1
    • 0030667327 scopus 로고    scopus 로고
    • Clinical and physiological effects of a new, less toxic and less acidic fluid for peritoneal dialysis
    • Rippe B, Simonsen O, Wieslander A, Landgren C. Clinical and physiological effects of a new, less toxic and less acidic fluid for peritoneal dialysis. Perit Dial Int 1997;17:27-34.
    • (1997) Perit Dial Int , vol.17 , pp. 27-34
    • Rippe, B.1    Simonsen, O.2    Wieslander, A.3    Landgren, C.4
  • 2
    • 0035162741 scopus 로고    scopus 로고
    • Long-term clinical effects of a peritoneal dialysis fluid with less glucose degradation products
    • Rippe B, Simonsen O, Heimbürger O, Christensson A, Haraldsson B, Stelin G, et al. Long-term clinical effects of a peritoneal dialysis fluid with less glucose degradation products. Kidney Int 2001; 59:348-57.
    • (2001) Kidney Int , vol.59 , pp. 348-357
    • Rippe, B.1    Simonsen, O.2    Heimbürger, O.3    Christensson, A.4    Haraldsson, B.5    Stelin, G.6
  • 3
    • 0038806762 scopus 로고    scopus 로고
    • Mass transfer of calcium across the peritoneum at three different peritoneal dialysis fluid Ca and glucose concentrations
    • Simonsen O, Wieslander A, Venturoli D, Carlsson O, Rippe B. Mass transfer of calcium across the peritoneum at three different peritoneal dialysis fluid Ca and glucose concentrations. Kidney Int 2003; 64:208-15.
    • (2003) Kidney Int , vol.64 , pp. 208-215
    • Simonsen, O.1    Wieslander, A.2    Venturoli, D.3    Carlsson, O.4    Rippe, B.5
  • 4
    • 0026569696 scopus 로고
    • Aqueous solute concentrations and evaluation of mass transport coefficients in peritoneal dialysis
    • Waniewski J, Heimbürger O, Werynski A, Lindholm B. Aqueous solute concentrations and evaluation of mass transport coefficients in peritoneal dialysis. Nephrol Dial Transplant 1992; 7:50-6.
    • (1992) Nephrol Dial Transplant , vol.7 , pp. 50-56
    • Waniewski, J.1    Heimbürger, O.2    Werynski, A.3    Lindholm, B.4
  • 5
    • 0029069141 scopus 로고
    • Intraperitoneal fluid volume changes during peritoneal dialysis in the rat. Indicator dilution vs volumetric measurements
    • Zakaria ER, Rippe B. Intraperitoneal fluid volume changes during peritoneal dialysis in the rat. Indicator dilution vs volumetric measurements. Blood Purif 1995; 13:255-70.
    • (1995) Blood Purif , vol.13 , pp. 255-270
    • Zakaria, E.R.1    Rippe, B.2
  • 6
    • 0002857024 scopus 로고
    • Peritoneal physiology - Transport of solutes
    • In: Gokal R, Nolph KD, eds. Dordrecht: Kluwer Academic Publishers
    • Rippe B, Krediet RT. Peritoneal physiology - transport of solutes. In: Gokal R, Nolph KD, eds. The Textbook of Peritoneal Dialysis. Dordrecht: Kluwer Academic Publishers; 1994:68-132.
    • (1994) The Textbook of Peritoneal Dialysis , pp. 68-132
    • Rippe, B.1    Krediet, R.T.2
  • 7
    • 0003016156 scopus 로고
    • Lymph flow from the peritoneal cavity in CAPD patients
    • In: Maher JF, Winchester JF, eds. New York: Field, Rich and Associates
    • Rippe B, Stelin G, Ahlmén J. Lymph flow from the peritoneal cavity in CAPD patients. In: Maher JF, Winchester JF, eds. Frontiers in Peritoneal Dialysis. New York: Field, Rich and Associates; 1986: 24-30.
    • (1986) Frontiers in Peritoneal Dialysis , pp. 24-30
    • Rippe, B.1    Stelin, G.2    Ahlmén, J.3
  • 8
    • 3042720430 scopus 로고    scopus 로고
    • The Euro-Balance Trial: The effect of a new biocompatible peritoneal dialysis fluid (balance) on the peritoneal membrane
    • Williams JD, Topley N, Craig KJ, Mackenzie RK, Pischetsrieder M, Lage C, et al. The Euro-Balance Trial: The effect of a new biocompatible peritoneal dialysis fluid (balance) on the peritoneal membrane. Kidney Int 2004; 66:408-18.
    • (2004) Kidney Int , vol.66 , pp. 408-418
    • Williams, J.D.1    Topley, N.2    Craig, K.J.3    Mackenzie, R.K.4    Pischetsrieder, M.5    Lage, C.6
  • 9
    • 0033653329 scopus 로고    scopus 로고
    • A Long-term study of bicarbonate/lactate-based peritoneal dialysis solution - Clinical benefits
    • The Bicarbonate/Lactate Study Group
    • Tranaeus A. A Long-term study of bicarbonate/lactate-based peritoneal dialysis solution - clinical benefits. The Bicarbonate/Lactate Study Group. Perit Dial Int 2000; 20: 516-23.
    • (2000) Perit Dial Int , vol.20 , pp. 516-523
    • Tranaeus, A.1
  • 11
    • 0027013227 scopus 로고
    • Bicarbonate is not the ultimate answer to the biocompatibility problems of CAPD solutions: A cytotoxicity test of CAPD solutions and effluents
    • Schambye HT, Pedersen FB, Wang P. Bicarbonate is not the ultimate answer to the biocompatibility problems of CAPD solutions: a cytotoxicity test of CAPD solutions and effluents. Adv Perit Dial 1992; 8:42-6.
    • (1992) Adv Perit Dial , vol.8 , pp. 42-46
    • Schambye, H.T.1    Pedersen, F.B.2    Wang, P.3
  • 12
    • 0029953197 scopus 로고    scopus 로고
    • Effect of different buffers on the biocompatibility of CAPD solutions
    • Schambye HT. Effect of different buffers on the biocompatibility of CAPD solutions. Perit Dial Int 1996; 16(Suppl 1):S130-6.
    • (1996) Perit Dial Int , vol.16 , Issue.SUPPL. 1
    • Schambye, H.T.1
  • 13
    • 15644368482 scopus 로고    scopus 로고
    • Bicarbonate and bicarbonate/lactate peritoneal dialysis solutions for the treatment of infusion pain
    • Mactier RA, Sprosen TS, Gokal R. Bicarbonate and bicarbonate/lactate peritoneal dialysis solutions for the treatment of infusion pain. Kidney Int 1998; 53:1061-7.
    • (1998) Kidney Int , vol.53 , pp. 1061-1067
    • Mactier, R.A.1    Sprosen, T.S.2    Gokal, R.3
  • 14
    • 0004218743 scopus 로고
    • New York: Oxford University Press
    • Folkow B, Neil E. Circulation. New York: Oxford University Press; 1971; 285-306.
    • (1971) Circulation , pp. 285-306
    • Folkow, B.1    Neil, E.2
  • 17
    • 0025873429 scopus 로고
    • Computer simulations of peritoneal fluid transport in CAPD
    • Rippe B, Stelin G, Haraldsson B. Computer simulations of peritoneal fluid transport in CAPD. Kidney Int 1991; 40: 315-25.
    • (1991) Kidney Int , vol.40 , pp. 315-325
    • Rippe, B.1    Stelin, G.2    Haraldsson, B.3
  • 18
    • 0033658561 scopus 로고    scopus 로고
    • Pathophysiology of peritoneal membrane failure
    • Krediet RT, Lindholm B, Rippe B. Pathophysiology of peritoneal membrane failure. Perit Dial Int 2000; 20(Suppl 4): S22-42.
    • (2000) Perit Dial Int , vol.20 , Issue.SUPPL. 4
    • Krediet, R.T.1    Lindholm, B.2    Rippe, B.3
  • 19
    • 3042812197 scopus 로고    scopus 로고
    • Fluid and electrolyte transport across the peritoneal membrane during CAPD
    • Rippe B, Venturoli D, Simonsen O, de Arteaga J. Fluid and electrolyte transport across the peritoneal membrane during CAPD. Perit Dial Int 2004; 24:10-27.
    • (2004) Perit Dial Int , vol.24 , pp. 10-27
    • Rippe, B.1    Venturoli, D.2    Simonsen, O.3    de Arteaga, J.4
  • 20
    • 0038512393 scopus 로고    scopus 로고
    • Blood flow Limitation in vivo of small solute transfer during peritoneal dialysis in rats
    • Rosengren B-I, Rippe B. Blood flow Limitation in vivo of small solute transfer during peritoneal dialysis in rats. J Am Soc Nephrol 2003; 14:1599-604.
    • (2003) J Am Soc Nephrol , vol.14 , pp. 1599-1604
    • Rosengren, B.-I.1    Rippe, B.2
  • 21
    • 0036151752 scopus 로고    scopus 로고
    • Hemodynamic effects of peritoneal dialysis solutions on the rat peritoneal membrane: Role of acidity, buffer choice, glucose concentration, and glucose degradation products
    • Mortier S, De Vriese AS, Van de Voorde J, Schaub TP, Passlick-Deetjen J, Lameire NH. Hemodynamic effects of peritoneal dialysis solutions on the rat peritoneal membrane: role of acidity, buffer choice, glucose concentration, and glucose degradation products. J Am Soc Nephrol 2002; 13:480-9.
    • (2002) J Am Soc Nephrol , vol.13 , pp. 480-489
    • Mortier, S.1    De Vriese, A.S.2    Van de Voorde, J.3    Schaub, T.P.4    Passlick-Deetjen, J.5    Lameire, N.H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.