메뉴 건너뛰기




Volumn 53, Issue 4, 2006, Pages 2409-2415

Performance comparison of a large volume CZT semiconductor detector and a LaBr3(Ce) scintillator detector

Author keywords

Coplanar; CZT; Gamma detector; LaBr3; Scintillator

Indexed keywords

CADMIUM COMPOUNDS; MONTE CARLO METHODS; PHOSPHORS; RADIATION DETECTORS; SCINTILLATION;

EID: 33748366581     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2006.877853     Document Type: Conference Paper
Times cited : (9)

References (13)
  • 4
    • 34547723673 scopus 로고
    • Single-polarity charge sensing in ionizing detectors using coplanar electrodes
    • Nov.
    • P. N. Luke, "Single-polarity charge sensing in ionizing detectors using coplanar electrodes," Appl. Phys. Lett., vol. 65, no. 22, pp. 2884-2886, Nov. 1994.
    • (1994) Appl. Phys. Lett. , vol.65 , Issue.22 , pp. 2884-2886
    • Luke, P.N.1
  • 5
    • 0029357607 scopus 로고
    • Unipolar charge sensing with coplanar electrodes application to semiconductor detectors
    • Aug.
    • P. N. Luke, "Unipolar charge sensing with coplanar electrodes application to semiconductor detectors," IEEE Trans. Nucl. Sci., vol. 42, no. 4, pp. 207-213, Aug. 1995.
    • (1995) IEEE Trans. Nucl. Sci. , vol.42 , Issue.4 , pp. 207-213
    • Luke, P.N.1
  • 7
    • 4544299339 scopus 로고    scopus 로고
    • Efficiency at different interactions depth in large coplanar CdZnTe detector
    • R. González, J. M. Pérez, and Z. He, "Efficiency at different interactions depth in large coplanar CdZnTe detector," Nucl. Instrum. Methods Phys. Res. A, vol. A531, pp. 544-559, 2004.
    • (2004) Nucl. Instrum. Methods Phys. Res. A , vol.A531 , pp. 544-559
    • González, R.1    Pérez, J.M.2    He, Z.3
  • 8
    • 0036703116 scopus 로고    scopus 로고
    • Estimate of large CZT detector absolute efficiency
    • Aug.
    • J. M. Pérez, Z. He, D. K. Wehe, and Y. F. Du, "Estimate of large CZT detector absolute efficiency," IEEE Trans. Nucl. Sci, vol. 49, no. 4, pp. 2010-2018, Aug. 2002.
    • (2002) IEEE Trans. Nucl. Sci , vol.49 , Issue.4 , pp. 2010-2018
    • Pérez, J.M.1    He, Z.2    Wehe, D.K.3    Du, Y.F.4
  • 9
    • 0032114882 scopus 로고    scopus 로고
    • Coplanar grid pattern and their effect on energy resolution of CdZnTe detectors
    • Z. He, G. K. Knoll, D. K. Wehe, and Y. F. Du, "Coplanar grid pattern and their effect on energy resolution of CdZnTe detectors," Nucl. Instrum. Methods Phys. Res. A, vol. A411, pp. 107-113, 1998.
    • (1998) Nucl. Instrum. Methods Phys. Res. A , vol.A411 , pp. 107-113
    • He, Z.1    Knoll, G.K.2    Wehe, D.K.3    Du, Y.F.4
  • 13
    • 4444249595 scopus 로고    scopus 로고
    • 4π compton imaging using a 3-D position-sensitive CdZnTe detector via weighted list-mode maximum likelihood
    • Aug.
    • C. E. Lehner, Z. He, and F. Zhang, "4π compton imaging using a 3-D position-sensitive CdZnTe detector via weighted list-mode maximum likelihood," IEEE Trans. Nucl. Sci, vol. 51, no. 4, pp. 1618-1624, Aug. 2004.
    • (2004) IEEE Trans. Nucl. Sci , vol.51 , Issue.4 , pp. 1618-1624
    • Lehner, C.E.1    He, Z.2    Zhang, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.