메뉴 건너뛰기




Volumn 13, Issue 4, 2006, Pages 820-829

Hydrophobicity transfer from silicone rubber to adhering pollutants and its effect on insulator performance

Author keywords

Ceramic insulators; Composite insulation; Electrical breakdown; Flashover; Hydrophobicity; Insulator contamination; Insulator testing; Pollution; Polymeric insulators; Silicone rubber; Silicone rubber insulators

Indexed keywords

CONTACT ANGLE; ELECTRIC INSULATION; ELECTRIC INSULATORS; FLASHOVER; HYDROPHOBICITY; RUBBER COATINGS; SILICONES; THERMAL POLLUTION;

EID: 33748316679     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2006.1667741     Document Type: Article
Times cited : (119)

References (30)
  • 1
    • 0005842524 scopus 로고    scopus 로고
    • CIGRE Taskforce 33.04.01: CIGRE Technical Brochure No. 158
    • CIGRE Taskforce 33.04.01: "Polluted insulators: review of current knowledge", CIGRE Technical Brochure No. 158, 2000.
    • (2000) Polluted Insulators: Review of Current Knowledge
  • 6
    • 0003160903 scopus 로고
    • Mathematical models for pollution flashover
    • F.A. M. Rizk, "Mathematical models for pollution flashover", Electra, No. 78,pp.71-103, 1981.
    • (1981) Electra , Issue.78 , pp. 71-103
    • Rizk, F.A.M.1
  • 7
    • 59349118982 scopus 로고
    • AC flashover mechanism for water droplets on an hydrophobic insulator
    • Paper 44.09, Yokohama, Japan
    • D.A. Swift, "AC flashover mechanism for water droplets on an hydrophobic insulator", 8th Intern. Sympos. High Voltage Engineering (ISH), Paper 44.09, Yokohama, Japan, pp. 113-116, 1993.
    • (1993) 8th Intern. Sympos. High Voltage Engineering (ISH) , pp. 113-116
    • Swift, D.A.1
  • 8
    • 0029386428 scopus 로고
    • Flashover mechanism of silicone rubber insulators used for outdoor insulation part 1 and part II
    • G.G. Karady, M. Shah and R.L. Brown, "Flashover mechanism of silicone rubber insulators used for outdoor insulation part I and part II, IEEE Trans. Power Delivery, Vol. 10, pp. 1965-1978, 1995.
    • (1995) IEEE Trans. Power Delivery , vol.10 , pp. 1965-1978
    • Karady, G.G.1    Shah, M.2    Brown, R.L.3
  • 9
    • 0028749565 scopus 로고
    • An investigation into the temporary loss of hydrophobicity of some polymeric insulators and coatings
    • Brisbane Australia
    • D.K. Bhana and D.A. Swift, "An investigation into the temporary loss of hydrophobicity of some polymeric insulators and coatings", IEEE 4th Intern. Conf. Properties and Applications of Dielectric Materials, Brisbane Australia, pp.294-297, 1994.
    • (1994) IEEE 4th Intern. Conf. Properties and Applications of Dielectric Materials , pp. 294-297
    • Bhana, D.K.1    Swift, D.A.2
  • 13
    • 33748311830 scopus 로고    scopus 로고
    • A new technique for pollution testing of polymeric insulators under Clean-fog conditions
    • Paper 5-1, Bangalore, India, August
    • C.A. Spellman, H. Young, A. Haddad and R. Stone, "A new technique for pollution testing of polymeric insulators under Clean-fog conditions", 12th Intern. Sympos. High Voltage Engineering (ISH), Vol. 3, Paper 5-1, Bangalore, India, August 2001.
    • (2001) 12th Intern. Sympos. High Voltage Engineering (ISH) , vol.3
    • Spellman, C.A.1    Young, H.2    Haddad, A.3    Stone, R.4
  • 14
    • 0021316481 scopus 로고
    • Influence of ac source parameters on flashover characteristics of polluted insulators
    • Seattle, USA
    • A.M. Rizk and M. Bourdages, "Influence of ac source parameters on flashover characteristics of polluted insulators", IEEE Power Engineering Society Meeting, Seattle, USA, pp.1-8, 1984.
    • (1984) IEEE Power Engineering Society Meeting , pp. 1-8
    • Rizk, A.M.1    Bourdages, M.2
  • 15
    • 33748322991 scopus 로고    scopus 로고
    • Hydrophobicity transfer from silicone rubber to adhering pollutants: Water-triggered flashover of this surface
    • Paper 5-20, Bangalore, India
    • D.A. Swift, C.A. Spellman and A. Haddad, "Hydrophobicity transfer from silicone rubber to adhering pollutants: water-triggered flashover of this surface", 12th Intern. Sympos. High Voltage Engineering (ISH), Vol.3, Paper 5-20, Bangalore, India, 2001.
    • (2001) 12th Intern. Sympos. High Voltage Engineering (ISH) , vol.3
    • Swift, D.A.1    Spellman, C.A.2    Haddad, A.3
  • 16
    • 33748316353 scopus 로고    scopus 로고
    • Leakage current on silicone rubber insulators and RTV coatings in clean fog: Hydrophobicity transfer to pollution
    • Paper 5-7, Bangalore, India
    • D.A. Swift, C.A. Spellman and A. Haddad, "Leakage current on silicone rubber insulators and RTV coatings in clean fog: hydrophobicity transfer to pollution", 12th Intern. Sympos. High Voltage Engineering (ISH), Vol.3, Paper 5-7, Bangalore, India, 2001.
    • (2001) 12th Intern. Sympos. High Voltage Engineering (ISH) , vol.3
    • Swift, D.A.1    Spellman, C.A.2    Haddad, A.3
  • 20
    • 33748291307 scopus 로고    scopus 로고
    • Hydrophobicity of composite insulators: Measurement and influence on electrical performance
    • Massachusetts (USA), March
    • R. Hartings, "Hydrophobicity of composite insulators: measurement and influence on electrical performance", 63rd Annual International Conference of Doble Clients, Massachusetts (USA), March 1996.
    • (1996) 63rd Annual International Conference of Doble Clients
    • Hartings, R.1
  • 23
    • 33746263007 scopus 로고
    • Surface hydrophobicity of polymeric materials used for outdoor insulation applications
    • Paper 30.05, New Orleans (USA)
    • J. Chang and R.S Gorur, "Surface hydrophobicity of polymeric materials used for outdoor insulation applications", 6th Intern. Sympos. High Voltage Engineering (ISH), Paper 30.05, New Orleans (USA), 1989.
    • (1989) 6th Intern. Sympos. High Voltage Engineering (ISH)
    • Chang, J.1    Gorur, R.S.2
  • 26
    • 33748308633 scopus 로고    scopus 로고
    • Guide to the measurement of wettability of insulator surfaces
    • IEC 62073
    • IEC 62073: "Guide to the measurement of wettability of insulator surfaces", Draft document 62073, 2002.
    • (2002) Draft Document 62073
  • 28
    • 0025505982 scopus 로고
    • Composite rod insulators for ac power lines; Electrical performance of various designs in a coastal testing station
    • R.G. Houlgate and D.A Swift, "Composite rod insulators for ac power lines; Electrical performance of various designs in a coastal testing station", IEEE Trans. Power Delivery, Vol.5, pp. 1944-1955, 1990.
    • (1990) IEEE Trans. Power Delivery , vol.5 , pp. 1944-1955
    • Houlgate, R.G.1    Swift, D.A.2
  • 29
    • 0001191099 scopus 로고
    • Disintegration of water drops in an electric field
    • G. Taylor, "Disintegration of water drops in an electric field", Proc. Roy. Soc., Series A, No. 1382, Vol.280, pp.383-397, 1964.
    • (1964) Proc. Roy. Soc., Series A , vol.280 , Issue.1382 , pp. 383-397
    • Taylor, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.