메뉴 건너뛰기




Volumn 70, Issue 3, 2006, Pages 668-675

Conversion of chromium(III) propionate to chromium(VI) by the Advanced Oxidation Process. Pretreatment of a biomimetic complex for metal analysis

Author keywords

Advanced Oxidation Process; Chromium; Hydrogen peroxide; Metal analysis; Pretreatment

Indexed keywords

CHROMIUM; COMPLEXATION; DISSOLUTION; HYDROGEN PEROXIDE; METAL ANALYSIS; ULTRAVIOLET RADIATION;

EID: 33748306001     PISSN: 00399140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.talanta.2006.05.092     Document Type: Article
Times cited : (22)

References (60)
  • 22
    • 0034246126 scopus 로고    scopus 로고
    • Residual carbon has been found to interfere with determination of chromium in blood and tissue samples using quadrupole ICP-MS
    • Rodushkin I., Ödman F., Olofsson R., and Axelsson M.D. J. Anal. At. Spectrom. 15 (2000) 937 Residual carbon has been found to interfere with determination of chromium in blood and tissue samples using quadrupole ICP-MS
    • (2000) J. Anal. At. Spectrom. , vol.15 , pp. 937
    • Rodushkin, I.1    Ödman, F.2    Olofsson, R.3    Axelsson, M.D.4
  • 23
    • 14944382555 scopus 로고    scopus 로고
    • Acid digestion and microwave (MW) heating have been used to pretreat biological samples in the analysis of chromium by, e.g., inductively coupled plasma mass spectrometry (ICP-MS)
    • Kunze J., Wimmer M.A., Reich M., Koelling S., and Jacobs J.J. At. Spectros. 26 (2005) 8 Acid digestion and microwave (MW) heating have been used to pretreat biological samples in the analysis of chromium by, e.g., inductively coupled plasma mass spectrometry (ICP-MS)
    • (2005) At. Spectros. , vol.26 , pp. 8
    • Kunze, J.1    Wimmer, M.A.2    Reich, M.3    Koelling, S.4    Jacobs, J.J.5
  • 35
    • 0034668007 scopus 로고    scopus 로고
    • 2, ozonation, and ultrasonic irradiation (through extreme temperatures and pressures) have also been used as extraction and decomposition methods. See, e.g., Ref. [10b] and
    • 2, ozonation, and ultrasonic irradiation (through extreme temperatures and pressures) have also been used as extraction and decomposition methods. See, e.g., Ref. [10b] and. Capelo J.L., Lavilla I., and Bendicho C. Anal. Chem. 72 (2000) 4979
    • (2000) Anal. Chem. , vol.72 , pp. 4979
    • Capelo, J.L.1    Lavilla, I.2    Bendicho, C.3
  • 50
    • 33748293191 scopus 로고    scopus 로고
    • Perkin-Elmer Corporation, Analytical Methods for Atomic Absorption Spectroscopy, 1996.
  • 54
    • 33748318230 scopus 로고    scopus 로고
    • See supplementary data for details.
  • 55
    • 33748324915 scopus 로고    scopus 로고
    • A nitrous oxide-acetylene flame at a higher temperature is expected to give accurate AA. However, we used the more common air-acetylene flame as a gauge in the current work for the degree of AOP pretreatment.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.