메뉴 건너뛰기




Volumn 41, Issue 9, 2006, Pages 1582-1587

Complications associated with an implantable vascular access device

Author keywords

Children; Complications; Portacath; Vascular access

Indexed keywords

ADOLESCENT; ARTICLE; ARTIFICIAL EMBOLISM; CATHETER; CHILD; HEMATOLOGY; HUMAN; MAJOR CLINICAL STUDY; MEDICAL RECORD; NEEDLE; NUCLEAR MAGNETIC RESONANCE IMAGING; ONCOLOGY; OUTCOME ASSESSMENT; PRIORITY JOURNAL; PULMONARY ARTERY; RADIOGRAPHY; RADIOLOGY; RESERVOIR; RISK ASSESSMENT; TIME SERIES ANALYSIS; VASCULAR ACCESS DEVICE;

EID: 33748067424     PISSN: 00223468     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jpedsurg.2006.05.022     Document Type: Article
Times cited : (67)

References (23)
  • 1
    • 0015611436 scopus 로고
    • A silicone rubber atrial catheter for prolonged parenteral alimentation
    • Broviac J.W., Cole J.J., and Scribner B.H. A silicone rubber atrial catheter for prolonged parenteral alimentation. Surg Gynecol Obstet 136 4 (1973) 602-606
    • (1973) Surg Gynecol Obstet , vol.136 , Issue.4 , pp. 602-606
    • Broviac, J.W.1    Cole, J.J.2    Scribner, B.H.3
  • 2
    • 0022652550 scopus 로고
    • Fifty-five patient years' experience with a totally implanted system for intravenous chemotherapy
    • Brincker H., and Salter G. Fifty-five patient years' experience with a totally implanted system for intravenous chemotherapy. Cancer 57 6 (1986) 1124-1129
    • (1986) Cancer , vol.57 , Issue.6 , pp. 1124-1129
    • Brincker, H.1    Salter, G.2
  • 3
    • 84907107376 scopus 로고
    • Totally implanted device for venous access. Experience in tumour patients
    • Starkhammar H., and Bengtsson M. Totally implanted device for venous access. Experience in tumour patients. Acta Radiol Oncol 24 2 (1985) 173-176
    • (1985) Acta Radiol Oncol , vol.24 , Issue.2 , pp. 173-176
    • Starkhammar, H.1    Bengtsson, M.2
  • 4
    • 0022482070 scopus 로고
    • Continuous venous access in children for long-term chemotherapy by means of an implantable system
    • Krul E.J., van Leeuwen E.F., Vos A., et al. Continuous venous access in children for long-term chemotherapy by means of an implantable system. J Pediatr Surg 21 8 (1986) 689-690
    • (1986) J Pediatr Surg , vol.21 , Issue.8 , pp. 689-690
    • Krul, E.J.1    van Leeuwen, E.F.2    Vos, A.3
  • 5
    • 12144290004 scopus 로고    scopus 로고
    • Follow-up of 452 totally implantable vascular devices in cystic fibrosis patients
    • Munck A., Malbezin S., Bloch J., et al. Follow-up of 452 totally implantable vascular devices in cystic fibrosis patients. Eur Respir J 23 3 (2004) 430-434
    • (2004) Eur Respir J , vol.23 , Issue.3 , pp. 430-434
    • Munck, A.1    Malbezin, S.2    Bloch, J.3
  • 6
    • 0032884848 scopus 로고    scopus 로고
    • Totally implantable central venous access devices for paediatric oncology patients
    • Munro F.D., Gillett P.M., Wratten J.C., et al. Totally implantable central venous access devices for paediatric oncology patients. Med Pediatr Oncol 33 4 (1999) 377-381
    • (1999) Med Pediatr Oncol , vol.33 , Issue.4 , pp. 377-381
    • Munro, F.D.1    Gillett, P.M.2    Wratten, J.C.3
  • 7
    • 0036845321 scopus 로고    scopus 로고
    • Totally implantable venous-access ports: local problems and extravasation injury
    • Kurul S., Saip P., and Aydin T. Totally implantable venous-access ports: local problems and extravasation injury. Lancet Oncol 3 11 (2002) 684-692
    • (2002) Lancet Oncol , vol.3 , Issue.11 , pp. 684-692
    • Kurul, S.1    Saip, P.2    Aydin, T.3
  • 8
    • 0036461108 scopus 로고    scopus 로고
    • Implanted vascular access devices (ports) in children: complications and their prevention
    • Babu R., and Spicer R.D. Implanted vascular access devices (ports) in children: complications and their prevention. Pediatr Surg Int 18 1 (2002) 50-53
    • (2002) Pediatr Surg Int , vol.18 , Issue.1 , pp. 50-53
    • Babu, R.1    Spicer, R.D.2
  • 9
    • 0023754096 scopus 로고
    • Comparison of totally implanted reservoirs with external catheters as venous access devices in pediatric oncologic patients
    • Ross M.N., Haase G.M., Poole M.A., et al. Comparison of totally implanted reservoirs with external catheters as venous access devices in pediatric oncologic patients. Surg Gynecol Obstet 167 2 (1988) 141-144
    • (1988) Surg Gynecol Obstet , vol.167 , Issue.2 , pp. 141-144
    • Ross, M.N.1    Haase, G.M.2    Poole, M.A.3
  • 10
    • 0029827594 scopus 로고    scopus 로고
    • Complications of venous access ports in 132 patients with disseminated testicular cancer treated with polychemotherapy
    • Lemmers N.W., Gels M.E., Sleijfer D.T., et al. Complications of venous access ports in 132 patients with disseminated testicular cancer treated with polychemotherapy. J Clin Oncol 14 11 (1996) 2916-2922
    • (1996) J Clin Oncol , vol.14 , Issue.11 , pp. 2916-2922
    • Lemmers, N.W.1    Gels, M.E.2    Sleijfer, D.T.3
  • 11
    • 84864526199 scopus 로고    scopus 로고
    • Totally implantable vascular access devices for cystic fibrosis
    • Rahman A., and Spencer D. Totally implantable vascular access devices for cystic fibrosis. Cochrane Database Syst Rev 3 (2003) CD004111
    • (2003) Cochrane Database Syst Rev , Issue.3
    • Rahman, A.1    Spencer, D.2
  • 12
    • 0025283419 scopus 로고
    • Totally implantable vascular access devices in cystic fibrosis: a four-year experience with fifty-eight patients
    • Morris J.B., Occhionero M.E., Gauderer M.W., et al. Totally implantable vascular access devices in cystic fibrosis: a four-year experience with fifty-eight patients. J Pediatr 117 1 Pt l (1990) 82-85
    • (1990) J Pediatr , vol.117 , Issue.1 PART l , pp. 82-85
    • Morris, J.B.1    Occhionero, M.E.2    Gauderer, M.W.3
  • 13
    • 0027031019 scopus 로고
    • Atypical thrombotic and septic complications of totally implantable venous access devices in patients with cystic fibrosis
    • Sola J.E., Stone M.M., Wise B., et al. Atypical thrombotic and septic complications of totally implantable venous access devices in patients with cystic fibrosis. Pediatr Pulmonol 14 4 (1992) 239-242
    • (1992) Pediatr Pulmonol , vol.14 , Issue.4 , pp. 239-242
    • Sola, J.E.1    Stone, M.M.2    Wise, B.3
  • 14
    • 0034072006 scopus 로고    scopus 로고
    • 5-Fluorouracil extravasation following port failure
    • Nesti S.P., and Kovac R. 5-Fluorouracil extravasation following port failure. J Intraven Nurs 23 3 (2000) 176-180
    • (2000) J Intraven Nurs , vol.23 , Issue.3 , pp. 176-180
    • Nesti, S.P.1    Kovac, R.2
  • 15
    • 0037238486 scopus 로고    scopus 로고
    • Ventricular tachycardia secondary to Port-a-Cath fracture and embolization
    • Denny M.A., and Frank L.R. Ventricular tachycardia secondary to Port-a-Cath fracture and embolization. J Emerg Med 24 l (2003) 29-34
    • (2003) J Emerg Med , vol.24 , Issue.l , pp. 29-34
    • Denny, M.A.1    Frank, L.R.2
  • 16
    • 0016312575 scopus 로고
    • Intravenous catheter emboli. Experience with twenty cases and collective review
    • Richardson J.D., Grover F.L., and Trinkle J.K. Intravenous catheter emboli. Experience with twenty cases and collective review. Am J Surg 128 6 (1974) 722-727
    • (1974) Am J Surg , vol.128 , Issue.6 , pp. 722-727
    • Richardson, J.D.1    Grover, F.L.2    Trinkle, J.K.3
  • 17
    • 0029949637 scopus 로고    scopus 로고
    • Catheter fracture: a rare complication of totally implantable subclavian venous access devices
    • Klotz H.P., Schopke W., Kohler A., et al. Catheter fracture: a rare complication of totally implantable subclavian venous access devices. J Surg Oncol 62 3 (1996) 222-225
    • (1996) J Surg Oncol , vol.62 , Issue.3 , pp. 222-225
    • Klotz, H.P.1    Schopke, W.2    Kohler, A.3
  • 18
    • 0031964073 scopus 로고    scopus 로고
    • Implantable vascular access systems: experience in 1500 patients with totally implanted central venous port systems
    • Kock H.J., Pietsch M., Krause U., et al. Implantable vascular access systems: experience in 1500 patients with totally implanted central venous port systems. World J Surg 22 1 (1998) 12-16
    • (1998) World J Surg , vol.22 , Issue.1 , pp. 12-16
    • Kock, H.J.1    Pietsch, M.2    Krause, U.3
  • 19
    • 0021705456 scopus 로고
    • The "pinch-off sign": a warning of impending problems with permanent subclavian catheters
    • Aitken D.R., and Minton J.P. The "pinch-off sign": a warning of impending problems with permanent subclavian catheters. Am J Surg 148 5 (1984) 633-636
    • (1984) Am J Surg , vol.148 , Issue.5 , pp. 633-636
    • Aitken, D.R.1    Minton, J.P.2
  • 20
  • 21
    • 0017836814 scopus 로고
    • Evaluation of current techniques for nonsurgical removal of intravascular iatrogenic foreign bodies
    • Fisher R.G., and Ferreyro R. Evaluation of current techniques for nonsurgical removal of intravascular iatrogenic foreign bodies. AJR Am J Roentgenol 130 3 (1978) 541-548
    • (1978) AJR Am J Roentgenol , vol.130 , Issue.3 , pp. 541-548
    • Fisher, R.G.1    Ferreyro, R.2
  • 22
    • 0036311849 scopus 로고    scopus 로고
    • Percutaneous retrieval of central venous catheter fragments
    • Andrews R.E., Tulloh R.M., and Rigby M.L. Percutaneous retrieval of central venous catheter fragments. Arch Dis Child 87 2 (2002) 149-150
    • (2002) Arch Dis Child , vol.87 , Issue.2 , pp. 149-150
    • Andrews, R.E.1    Tulloh, R.M.2    Rigby, M.L.3
  • 23
    • 0037305671 scopus 로고    scopus 로고
    • Experience at a single institution with endovascular treatment of mechanical complications caused by implanted central venous access devices in pediatric and adult patients
    • Bessoud B., de Baere T., Kuoch V., et al. Experience at a single institution with endovascular treatment of mechanical complications caused by implanted central venous access devices in pediatric and adult patients. AJR Am J Roentgenol 180 2 (2003) 527-532
    • (2003) AJR Am J Roentgenol , vol.180 , Issue.2 , pp. 527-532
    • Bessoud, B.1    de Baere, T.2    Kuoch, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.