Cutting balloon inflation for drug-eluting stent underexpansion due to unrecognized coronary arterial calcification

Author keywords

Balloon inflation; Calcification; Drug eluting stent; Intravascular ultrasound

Indexed keywords

ACETYLSALICYLIC ACID; ALLOPURINOL; ATORVASTATIN; CLOPIDOGREL; FENOFIBRATE; METFORMIN; VALSARTAN;

EID: 33747894680     PISSN: 15538389     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.carrev.2006.05.005     Document Type: Article
Times cited : (19)

References (19)
  • 1
    • 20144388922 scopus 로고    scopus 로고
    • Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study
    • Fujii K., Carlier S., Mintz G., et al. Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study. J Am Coll Cardiol 45 (2005) 995-998
    • (2005) J Am Coll Cardiol , vol.45 , pp. 995-998
    • Fujii, K.1    Carlier, S.2    Mintz, G.3
  • 2
    • 12144286893 scopus 로고    scopus 로고
    • Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis
    • Fujii K., Mintz G., Kobayashi Y., et al. Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis. Circulation 109 (2004) 1085-1088
    • (2004) Circulation , vol.109 , pp. 1085-1088
    • Fujii, K.1    Mintz, G.2    Kobayashi, Y.3
  • 3
    • 0026049106 scopus 로고
    • Cutting balloon: a novel approach to percutaneous angioplasty
    • Barath P., Fishbein M., Vari S., et al. Cutting balloon: a novel approach to percutaneous angioplasty. Am J Cardiol 68 (1991) 1249-1252
    • (1991) Am J Cardiol , vol.68 , pp. 1249-1252
    • Barath, P.1    Fishbein, M.2    Vari, S.3
  • 4
    • 0036596222 scopus 로고    scopus 로고
    • The Barath cutting balloon: battling the sword of Damocles
    • Rocha-Singh K. The Barath cutting balloon: battling the sword of Damocles. Catheter Cardiolvasc Interv 56 (2002) 232-233
    • (2002) Catheter Cardiolvasc Interv , vol.56 , pp. 232-233
    • Rocha-Singh, K.1
  • 5
    • 0030900834 scopus 로고    scopus 로고
    • Management of resistant coronary lesions by the cutting balloon catheter: initial experience
    • Bertrand O., Bonan R., Bilodeau L., et al. Management of resistant coronary lesions by the cutting balloon catheter: initial experience. Catheter Cardiolvasc Interv 41 (1997) 179-184
    • (1997) Catheter Cardiolvasc Interv , vol.41 , pp. 179-184
    • Bertrand, O.1    Bonan, R.2    Bilodeau, L.3
  • 6
    • 0035190714 scopus 로고    scopus 로고
    • Cutting balloon angioplasty for treatment of calcified coronary lesions
    • Karvouni E., Stankovic G., Albiero R., et al. Cutting balloon angioplasty for treatment of calcified coronary lesions. Cathet Cardiol Interv 54 (2001) 473-481
    • (2001) Cathet Cardiol Interv , vol.54 , pp. 473-481
    • Karvouni, E.1    Stankovic, G.2    Albiero, R.3
  • 7
    • 0031853470 scopus 로고    scopus 로고
    • Successful predilatation of a resistant, heavily calcified lesion with cutting balloon for coronary stenting: a case report
    • Asakura Y., Furukawa Y., Ishikawa S., et al. Successful predilatation of a resistant, heavily calcified lesion with cutting balloon for coronary stenting: a case report. Catheter Cardiovasc Diagn 44 (1998) 420-422
    • (1998) Catheter Cardiovasc Diagn , vol.44 , pp. 420-422
    • Asakura, Y.1    Furukawa, Y.2    Ishikawa, S.3
  • 8
    • 0030920326 scopus 로고    scopus 로고
    • Cutting balloon angioplasty and stenting for aorto-ostial lesions
    • Kurbaan A., Kelly P., and Sigwart U. Cutting balloon angioplasty and stenting for aorto-ostial lesions. Heart 77 (1997) 350-352
    • (1997) Heart , vol.77 , pp. 350-352
    • Kurbaan, A.1    Kelly, P.2    Sigwart, U.3
  • 9
    • 0034857558 scopus 로고    scopus 로고
    • Cutting balloon angioplasty for the treatment of in-stent restenosis: a matched comparison with rotational atherectomy, additional stent implantation and balloon angioplasty
    • Adamian M., Colombo A., Briguori C., et al. Cutting balloon angioplasty for the treatment of in-stent restenosis: a matched comparison with rotational atherectomy, additional stent implantation and balloon angioplasty. J Am Coll Cardiol 38 (2001) 672-679
    • (2001) J Am Coll Cardiol , vol.38 , pp. 672-679
    • Adamian, M.1    Colombo, A.2    Briguori, C.3
  • 10
    • 0028905580 scopus 로고
    • Patterns of calcification in coronary artery disease: a statistical analysis of intravascular ultrasound and coronary angiography in 1155 lesions
    • Mintz G., Popma J., Pichard A., et al. Patterns of calcification in coronary artery disease: a statistical analysis of intravascular ultrasound and coronary angiography in 1155 lesions. Circulation 91 (1995) 1959-1965
    • (1995) Circulation , vol.91 , pp. 1959-1965
    • Mintz, G.1    Popma, J.2    Pichard, A.3
  • 11
    • 0037678479 scopus 로고    scopus 로고
    • Impact of intravascular ultrasound-guided stenting on long-term clinical outcome: a meta-analysis of available studies comparing intravascular ultrasound-guided and angiographically guided stenting
    • Casella G., Klauss V., Ottani F., Siebert U., Sangiorgio P., and Bracchetti D. Impact of intravascular ultrasound-guided stenting on long-term clinical outcome: a meta-analysis of available studies comparing intravascular ultrasound-guided and angiographically guided stenting. Catheter Cardiovasc Interv 59 3 (2003) 314-321
    • (2003) Catheter Cardiovasc Interv , vol.59 , Issue.3 , pp. 314-321
    • Casella, G.1    Klauss, V.2    Ottani, F.3    Siebert, U.4    Sangiorgio, P.5    Bracchetti, D.6
  • 13
  • 14
    • 0027471917 scopus 로고
    • Parallel angioplasty dilatation catheter and guide wire: a new technique for the dilatation of calcified coronary arteries
    • Yazdanfar S., Ledley G., Alferi A., Strauss C., and Kotler M. Parallel angioplasty dilatation catheter and guide wire: a new technique for the dilatation of calcified coronary arteries. Cathet Cardiovasc Diagn 28 (1993) 72-75
    • (1993) Cathet Cardiovasc Diagn , vol.28 , pp. 72-75
    • Yazdanfar, S.1    Ledley, G.2    Alferi, A.3    Strauss, C.4    Kotler, M.5
  • 15
    • 23044447487 scopus 로고    scopus 로고
    • My buddy, my friend: focused force angioplasty using the buddy wire technique in an inadequately expanded stent
    • Meerkin D. My buddy, my friend: focused force angioplasty using the buddy wire technique in an inadequately expanded stent. Catheter Cardiol Interv 65 (2005) 513-515
    • (2005) Catheter Cardiol Interv , vol.65 , pp. 513-515
    • Meerkin, D.1
  • 16
    • 0028233965 scopus 로고
    • Longitudinal force focused coronary angioplasty: a technique for resistant lesions
    • Stillabower M. Longitudinal force focused coronary angioplasty: a technique for resistant lesions. Catheter Cardiovasc Diagn 32 (1994) 196-198
    • (1994) Catheter Cardiovasc Diagn , vol.32 , pp. 196-198
    • Stillabower, M.1
  • 17
    • 0037308559 scopus 로고    scopus 로고
    • Fracture of cutting balloon microsurgical blade inside coronary artery during angioplasty of tough restenotic lesion: a case report
    • Haridas K., Vijayakumar M., Viveka K., et al. Fracture of cutting balloon microsurgical blade inside coronary artery during angioplasty of tough restenotic lesion: a case report. Catheter Cardiovasc Interv 58 (2003) 199-201
    • (2003) Catheter Cardiovasc Interv , vol.58 , pp. 199-201
    • Haridas, K.1    Vijayakumar, M.2    Viveka, K.3
  • 18
    • 0036267290 scopus 로고    scopus 로고
    • Coronary stent strut avulsion in aorto-ostial in-stent restenosis: potential complication after cutting balloon angioplasty
    • Wang H., Kao H., Liau C., et al. Coronary stent strut avulsion in aorto-ostial in-stent restenosis: potential complication after cutting balloon angioplasty. Catheter Cardiovasc Interv 56 (2002) 215-219
    • (2002) Catheter Cardiovasc Interv , vol.56 , pp. 215-219
    • Wang, H.1    Kao, H.2    Liau, C.3
  • 19
    • 0036790684 scopus 로고    scopus 로고
    • Extraction of previously deployed stent by an entrapped cutting balloon due to blade fracture
    • Kawamura A., Asakura Y., Ishikawa S., et al. Extraction of previously deployed stent by an entrapped cutting balloon due to blade fracture. Catheter Cardiovasc Interv 57 (2002) 239-243
    • (2002) Catheter Cardiovasc Interv , vol.57 , pp. 239-243
    • Kawamura, A.1    Asakura, Y.2    Ishikawa, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.