메뉴 건너뛰기




Volumn 100, Issue 5, 2006, Pages 359-364

Calculations of the corrections for the true summation of cascade γ rays on the basis of statistical simulation using evaluated nuclear data

Author keywords

[No Author keywords available]

Indexed keywords

ATOMIC NUCLEI; GERMANIUM DETECTOR; NUCLEAR DATA; STATISTICAL SIMULATION;

EID: 33747887457     PISSN: 10634258     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10512-006-0094-4     Document Type: Article
Times cited : (2)

References (12)
  • 1
    • 0006505877 scopus 로고
    • Taking account of cascade transitions when determining the absolute yield of γ rays
    • D. S. Andreev, K. I. Erokhina, V. S. Zvonov, and I. Kh. Lemberg, "Taking account of cascade transitions when determining the absolute yield of γ rays," Prib. Tekh. Éksp., 5, 63-65 (1972).
    • (1972) Prib. Tekh. Éksp. , vol.5 , pp. 63-65
    • Andreev, D.S.1    Erokhina, K.I.2    Zvonov, V.S.3    Lemberg, I.Kh.4
  • 2
    • 0342413300 scopus 로고
    • Determination of the detection efficiency for γ rays in the energy peaks using nuclides with a complicated decay scheme under near-geometry conditions
    • D. S. Andreev, K. I. Erokhina, V. S. Zvonov, and I. Kh. Lemberg, "Determination of the detection efficiency for γ rays in the energy peaks using nuclides with a complicated decay scheme under near-geometry conditions," Izv. Akad Nauk SSSR, Ser. fiz., 37, 1609-1612 (1973).
    • (1973) Izv. Akad Nauk SSSR, Ser. Fiz. , vol.37 , pp. 1609-1612
    • Andreev, D.S.1    Erokhina, K.I.2    Zvonov, V.S.3    Lemberg, I.Kh.4
  • 3
    • 0030439418 scopus 로고    scopus 로고
    • Estimation of true coincidence corrections for voluminous sources
    • V. P. Kolotov, V. V. Atrashkevich, and S. Gelsema, "Estimation of true coincidence corrections for voluminous sources," Rad. Nucl. Chem., 210, No. 4, 183-196 (1996).
    • (1996) Rad. Nucl. Chem. , vol.210 , Issue.4 , pp. 183-196
    • Kolotov, V.P.1    Atrashkevich, V.V.2    Gelsema, S.3
  • 4
    • 0031208964 scopus 로고    scopus 로고
    • A new summing-correction method for γ efficiency calibration with multi-ray radionuclides
    • I. Ramos-Lerate, M. Barrera, R. Ligero, and M. Casas-Ruiz, "A new summing-correction method for γ efficiency calibration with multi-ray radionuclides," Nucl. Instrum. Meth. Phys. Res., 395A, 202-206 (1997).
    • (1997) Nucl. Instrum. Meth. Phys. Res. , vol.395 A , pp. 202-206
    • Ramos-Lerate, I.1    Barrera, M.2    Ligero, R.3    Casas-Ruiz, M.4
  • 5
    • 0034246092 scopus 로고    scopus 로고
    • Accurate calculation of total efficiency of Ge well-type detectors suitable for efficiency calibration using common standard source
    • O. Sima, "Accurate calculation of total efficiency of Ge well-type detectors suitable for efficiency calibration using common standard source," ibid., Nucl. Instrum. Meth. Phys. Res., 450A, 98-108 (2000).
    • (2000) Nucl. Instrum. Meth. Phys. Res. , vol.450 A , pp. 98-108
    • Sima, O.1
  • 6
    • 0000254615 scopus 로고
    • Coincidence-summing corrections for extended sources in γ-ray spectrometry using Monte Carlo simulation
    • M. Docombaz, J.-J. Gostely, and J.-P. Laedermann, "Coincidence- summing corrections for extended sources in γ-ray spectrometry using Monte Carlo simulation," ibid., Nucl. Instrum. Meth. Phys. Res., 312, 152-159 (1992).
    • (1992) Nucl. Instrum. Meth. Phys. Res. , vol.312 , pp. 152-159
    • Docombaz, M.1    Gostely, J.-J.2    Laedermann, J.-P.3
  • 7
    • 0030250078 scopus 로고    scopus 로고
    • Self-attenuation and coincidence-summing corrections calculated by Monte Carlo simulations for γ-spectrometric measurements with well-type germanium detectors
    • O. Sima and D. Arnold, "Self-attenuation and coincidence-summing corrections calculated by Monte Carlo simulations for γ-spectrometric measurements with well-type germanium detectors," Appl. Radiat. Isot., 47, 889-893 (1996).
    • (1996) Appl. Radiat. Isot. , vol.47 , pp. 889-893
    • Sima, O.1    Arnold, D.2
  • 8
    • 0034662374 scopus 로고    scopus 로고
    • Monte Carlo calculation of the efficiency calibration curve and coincidence-summing corrections in low-level γ-ray spectrometry using well-type HPGe detectors
    • J.-M. Laborie, G. Le Petit, D. Abt, and M. Girard, "Monte Carlo calculation of the efficiency calibration curve and coincidence-summing corrections in low-level γ-ray spectrometry using well-type HPGe detectors," ibid., Appl. Radiat. Isot., 53, 57-62 (2000).
    • (2000) Appl. Radiat. Isot. , vol.53 , pp. 57-62
    • Laborie, J.-M.1    Le Petit, G.2    Abt, D.3    Girard, M.4
  • 9
    • 17844410381 scopus 로고    scopus 로고
    • A Monte Carlo approach to true-coincidence summing correction factor calculation for γ-ray spectrometry applications
    • A. N. Berlizov and V. V. Tryshyn, "A Monte Carlo approach to true-coincidence summing correction factor calculation for γ-ray spectrometry applications," Rad. Nucl. Chem., 264, 169-174 (2005).
    • (2005) Rad. Nucl. Chem. , vol.264 , pp. 169-174
    • Berlizov, A.N.1    Tryshyn, V.V.2
  • 12
    • 10644219501 scopus 로고    scopus 로고
    • The 2002 IAEA test spectra for low-level γ-ray spectrometry software
    • J. Los Arcos, M. Baauw, S. Frinic, and V. P. Kolotov, "The 2002 IAEA test spectra for low-level γ-ray spectrometry software," Nucl. Insrum. Meth. Phys. Res., 536A, No. 1-2, 189-195 (2005).
    • (2005) Nucl. Insrum. Meth. Phys. Res. , vol.536 A , Issue.1-2 , pp. 189-195
    • Los Arcos, J.1    Baauw, M.2    Frinic, S.3    Kolotov, V.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.