Diagnostic Value of the 12-Lead Electrocardiogram during Conventional and Biventricular Pacing for Cardiac Resynchronization

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFICIAL HEART PACEMAKER; CARDIAC RESYNCHRONIZATION THERAPY; ELECTROCARDIOGRAM; ELECTROCARDIOGRAPHY; HEART ATRIUM FIBRILLATION; HEART ATRIUM PACING; HEART PACING; HEART RIGHT VENTRICLE OUTFLOW TRACT; HUMAN; HYPERKALEMIA; HYPERTROPHIC OBSTRUCTIVE CARDIOMYOPATHY; PRIORITY JOURNAL; Q WAVE; QRS COMPLEX; R WAVE; REVIEW;

EID: 33747879511     PISSN: 07338651     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ccl.2006.05.001     Document Type: Review
Times cited : (23)

References (71)
  • 1
    • 0034777236 scopus 로고    scopus 로고
    • The paced 12-lead electrocardiogram should no longer be neglected in pacemaker follow-up
    • Barold S.S., Levine P.A., and Ovsyshcher I.E. The paced 12-lead electrocardiogram should no longer be neglected in pacemaker follow-up. PACE 24 (2001) 1455-1458
    • (2001) PACE , vol.24 , pp. 1455-1458
    • Barold, S.S.1    Levine, P.A.2    Ovsyshcher, I.E.3
  • 3
    • 15244354092 scopus 로고    scopus 로고
    • Electrocardiogram interpretation with biventricular pacing devices
    • Hayes D.L., Wang P.J., Sackner-Bernstein J., and Asirvatham S.J. (Eds), Blackwell-Futura, Oxford (UK)
    • Asirvatham S.J. Electrocardiogram interpretation with biventricular pacing devices. In: Hayes D.L., Wang P.J., Sackner-Bernstein J., and Asirvatham S.J. (Eds). Resynchronization and defibrillation for heart failure. A practical approach (2004), Blackwell-Futura, Oxford (UK) 73-97
    • (2004) Resynchronization and defibrillation for heart failure. A practical approach , pp. 73-97
    • Asirvatham, S.J.1
  • 4
    • 15244351207 scopus 로고    scopus 로고
    • Troubleshooting and programming of cardiac resynchronization therapy
    • Ellenbogen K.A., Kay G.N., and Wilkoff B.L. (Eds), WB Saunders, Philadelphia (PA)
    • Kay G.N. Troubleshooting and programming of cardiac resynchronization therapy. In: Ellenbogen K.A., Kay G.N., and Wilkoff B.L. (Eds). Device therapy for congestive heart failure (2004), WB Saunders, Philadelphia (PA) 232-293
    • (2004) Device therapy for congestive heart failure , pp. 232-293
    • Kay, G.N.1
  • 6
    • 0242680368 scopus 로고    scopus 로고
    • Advances in devices for cardiac resynchronization in heart failure
    • Lau C.P., Barold S., Tse H.F., et al. Advances in devices for cardiac resynchronization in heart failure. J Interv Card Electrophysiol 9 (2003) 167-181
    • (2003) J Interv Card Electrophysiol , vol.9 , pp. 167-181
    • Lau, C.P.1    Barold, S.2    Tse, H.F.3
  • 7
    • 84954214235 scopus 로고    scopus 로고
    • Electrocardiography of multisite ventricular pacing
    • Barold S.S., and Mugica J. (Eds), Blackwell-Futura, Elmsford (NY)
    • Garrigue S., Barold S.S., and Clémenty J. Electrocardiography of multisite ventricular pacing. In: Barold S.S., and Mugica J. (Eds). The fifth decade of cardiac pacing (2004), Blackwell-Futura, Elmsford (NY) 84-100
    • (2004) The fifth decade of cardiac pacing , pp. 84-100
    • Garrigue, S.1    Barold, S.S.2    Clémenty, J.3
  • 8
    • 14444285461 scopus 로고
    • Normal and abnormal patterns of ventricular depolarization during cardiac pacing
    • Barold S.S. (Ed), Futura, Mt. Kisco (NY)
    • Barold S.S. Normal and abnormal patterns of ventricular depolarization during cardiac pacing. In: Barold S.S. (Ed). Modern cardiac pacing (1985), Futura, Mt. Kisco (NY) 545-569
    • (1985) Modern cardiac pacing , pp. 545-569
    • Barold, S.S.1
  • 9
    • 0021086191 scopus 로고
    • Electrocardiographic analysis of normal and abnormal pacemaker function
    • Dreifus L.S. (Ed), F.A.Davis, Philadelphia (PA)
    • Barold S.S., Falkoff M.D., Ong L.S., et al. Electrocardiographic analysis of normal and abnormal pacemaker function. In: Dreifus L.S. (Ed). Pacemaker therapy, cardiovascular clinics (1983), F.A.Davis, Philadelphia (PA) 97-134
    • (1983) Pacemaker therapy, cardiovascular clinics , pp. 97-134
    • Barold, S.S.1    Falkoff, M.D.2    Ong, L.S.3
  • 10
    • 0023387019 scopus 로고
    • Electrocardiographic diagnosis of myocardial infarction during ventricular pacing
    • Barold S.S., Falkoff M.D., Ong L.S., et al. Electrocardiographic diagnosis of myocardial infarction during ventricular pacing. Cardiol Clin 5 (1987) 403-417
    • (1987) Cardiol Clin , vol.5 , pp. 403-417
    • Barold, S.S.1    Falkoff, M.D.2    Ong, L.S.3
  • 11
    • 0021871236 scopus 로고
    • Unusual QRS morphology associated with transvenous pacemakers. The pseudo RBBB pattern
    • Klein H.O., Becker B., Sareli P., et al. Unusual QRS morphology associated with transvenous pacemakers. The pseudo RBBB pattern. Chest 87 (1985) 517-521
    • (1985) Chest , vol.87 , pp. 517-521
    • Klein, H.O.1    Becker, B.2    Sareli, P.3
  • 12
    • 0037269910 scopus 로고    scopus 로고
    • Safe right bundle branch block pattern during permanent right ventricular pacing
    • Yang Y.N., Yin W.H., and Young M.S. Safe right bundle branch block pattern during permanent right ventricular pacing. J Electrocardiol 36 (2003) 67-71
    • (2003) J Electrocardiol , vol.36 , pp. 67-71
    • Yang, Y.N.1    Yin, W.H.2    Young, M.S.3
  • 13
    • 0028801177 scopus 로고
    • Incidence and electrocardiographic localization of safe right bundle branch block configurations during permanent ventricular pacing
    • Coman J.A., and Trohman R.G. Incidence and electrocardiographic localization of safe right bundle branch block configurations during permanent ventricular pacing. Am J Cardiol 76 (1995) 781-784
    • (1995) Am J Cardiol , vol.76 , pp. 781-784
    • Coman, J.A.1    Trohman, R.G.2
  • 14
    • 1542575157 scopus 로고    scopus 로고
    • Asymptomatic malposition of a pacing lead in the left ventricle: the case of a woman untreated with anticoagulant therapy for eight years
    • Ciolli A., Trambaiolo P., Lo Sardo G., et al. Asymptomatic malposition of a pacing lead in the left ventricle: the case of a woman untreated with anticoagulant therapy for eight years. Ital Heart J 4 (2003) 562-564
    • (2003) Ital Heart J , vol.4 , pp. 562-564
    • Ciolli, A.1    Trambaiolo, P.2    Lo Sardo, G.3
  • 16
    • 16544376945 scopus 로고    scopus 로고
    • An unusual cause of stroke in a patient with permanent transvenous pacemaker
    • Ergun K., Tufekcioglu O., Karabal O., et al. An unusual cause of stroke in a patient with permanent transvenous pacemaker. Jpn Heart J 45 (2004) 873-875
    • (2004) Jpn Heart J , vol.45 , pp. 873-875
    • Ergun, K.1    Tufekcioglu, O.2    Karabal, O.3
  • 17
    • 0035701120 scopus 로고    scopus 로고
    • Cerebral embolism resulting from a transvenous pacemaker catheter inadvertently placed in the left ventricle: a report of two cases confirmed by echocardiography
    • Arnar D.O., and Kerber R.E. Cerebral embolism resulting from a transvenous pacemaker catheter inadvertently placed in the left ventricle: a report of two cases confirmed by echocardiography. Echocardiography 18 (2001) 681-684
    • (2001) Echocardiography , vol.18 , pp. 681-684
    • Arnar, D.O.1    Kerber, R.E.2
  • 18
    • 0029049452 scopus 로고
    • Inadvertent malposition of a transvenous inserted pacing lead in the left ventricular chamber
    • Sharafi M., Sorkin R., Sharifi V., et al. Inadvertent malposition of a transvenous inserted pacing lead in the left ventricular chamber. Am J Cardiol 76 (1995) 92-95
    • (1995) Am J Cardiol , vol.76 , pp. 92-95
    • Sharafi, M.1    Sorkin, R.2    Sharifi, V.3
  • 19
    • 0033974079 scopus 로고    scopus 로고
    • Malpositioned ventricular pacing l lead in the left ventricle
    • Burkart T.A., Lewis J.F., Conti J.B., et al. Malpositioned ventricular pacing l lead in the left ventricle. Clin Cardiol 23 (2000) 123-124
    • (2000) Clin Cardiol , vol.23 , pp. 123-124
    • Burkart, T.A.1    Lewis, J.F.2    Conti, J.B.3
  • 20
    • 0033734991 scopus 로고    scopus 로고
    • A cardiac embolic stroke due to malposition of the pacemaker lead in the left ventricle. A case report
    • Agnelli D., Ferrari A., Saltafossi D., et al. A cardiac embolic stroke due to malposition of the pacemaker lead in the left ventricle. A case report. Ital Heart J 1 1 Suppl (2000) 122-125
    • (2000) Ital Heart J , vol.1 , Issue.1 SUPPL , pp. 122-125
    • Agnelli, D.1    Ferrari, A.2    Saltafossi, D.3
  • 21
    • 0142089400 scopus 로고    scopus 로고
    • Diagnosis and management of inadvertently placed pacing and ICD leads in the left ventricle: a multicenter experience and review of the literature
    • Van Gelder B.M., Bracke F.A., Oto A., et al. Diagnosis and management of inadvertently placed pacing and ICD leads in the left ventricle: a multicenter experience and review of the literature. PACE 23 (2000) 877-883
    • (2000) PACE , vol.23 , pp. 877-883
    • Van Gelder, B.M.1    Bracke, F.A.2    Oto, A.3
  • 22
    • 0034183873 scopus 로고    scopus 로고
    • Inadvertent transvenous left ventricular pacing. A case report
    • Agarwal A., Kapoor A., and Garg N. Inadvertent transvenous left ventricular pacing. A case report. Indian Heart J 52 (2000) 331-334
    • (2000) Indian Heart J , vol.52 , pp. 331-334
    • Agarwal, A.1    Kapoor, A.2    Garg, N.3
  • 23
    • 84921430707 scopus 로고    scopus 로고
    • Images in cardiology. Ventricular pacing and right bundle branch block morphology: diagnosis and management
    • Blommaert D., Mucumbitsi J., and de Roy L. Images in cardiology. Ventricular pacing and right bundle branch block morphology: diagnosis and management. Heart 83 (2000) 666
    • (2000) Heart , vol.83 , pp. 666
    • Blommaert, D.1    Mucumbitsi, J.2    de Roy, L.3
  • 24
    • 0032971172 scopus 로고    scopus 로고
    • Pocket infection complicating inadvertent transarterial permanent pacing. Successful percutaneous explantation
    • Trigano J.A., Paganelli F., Fekhar S., et al. Pocket infection complicating inadvertent transarterial permanent pacing. Successful percutaneous explantation. Clin Cardiol 22 (1999) 492-493
    • (1999) Clin Cardiol , vol.22 , pp. 492-493
    • Trigano, J.A.1    Paganelli, F.2    Fekhar, S.3
  • 25
    • 11144297188 scopus 로고    scopus 로고
    • Left ventricular malposition of pacemaker lead in Chagas' disease
    • Chun J.K., Bode F., and Wiegand U.K. Left ventricular malposition of pacemaker lead in Chagas' disease. Pacing Clin Electrophysiol 27 (2004) 1682-1685
    • (2004) Pacing Clin Electrophysiol , vol.27 , pp. 1682-1685
    • Chun, J.K.1    Bode, F.2    Wiegand, U.K.3
  • 26
    • 0032874592 scopus 로고    scopus 로고
    • Transesophageal echocardiographic visualization of left ventricular malpositioned pacemaker electrodes: implications for lead extraction procedures
    • Orlov M.V., Messenger J.C., Tobias S., et al. Transesophageal echocardiographic visualization of left ventricular malpositioned pacemaker electrodes: implications for lead extraction procedures. Pacing Clin Electrophysiol 22 (1999) 1407-1409
    • (1999) Pacing Clin Electrophysiol , vol.22 , pp. 1407-1409
    • Orlov, M.V.1    Messenger, J.C.2    Tobias, S.3
  • 27
    • 0036697224 scopus 로고    scopus 로고
    • Transvenous pacemaker malposition in the systemic circulation and pacemaker infection: a case report and review of the literature
    • AL-Dashti R., Huynh T., Rosengarten M., et al. Transvenous pacemaker malposition in the systemic circulation and pacemaker infection: a case report and review of the literature. Can J Cardiol 18 (2002) 887-890
    • (2002) Can J Cardiol , vol.18 , pp. 887-890
    • AL-Dashti, R.1    Huynh, T.2    Rosengarten, M.3
  • 28
    • 0037749865 scopus 로고    scopus 로고
    • Images in clinical medicine. Malposition of dual-chamber pacemaker lead
    • Firschke C., and Zrenner B. Images in clinical medicine. Malposition of dual-chamber pacemaker lead. N Engl J Med 346 (2002) e2
    • (2002) N Engl J Med , vol.346
    • Firschke, C.1    Zrenner, B.2
  • 29
    • 0024583975 scopus 로고
    • Inadvertent permanent ventricular pacing from the coronary vein: an electrocardiographic, roentgenographic, and echocardiographic assessment
    • Shettigar U.R., Loungani R.R., and Smith C.A. Inadvertent permanent ventricular pacing from the coronary vein: an electrocardiographic, roentgenographic, and echocardiographic assessment. Clin Cardiol 12 (1989) 267-274
    • (1989) Clin Cardiol , vol.12 , pp. 267-274
    • Shettigar, U.R.1    Loungani, R.R.2    Smith, C.A.3
  • 30
    • 0034759369 scopus 로고    scopus 로고
    • Left ventricular pacing via the great cardiac vein in a patient with tricuspid and pulmonary valve replacement
    • Altmiks R., and Nathan A.W. Left ventricular pacing via the great cardiac vein in a patient with tricuspid and pulmonary valve replacement. Heart 85 (2001) 91
    • (2001) Heart , vol.85 , pp. 91
    • Altmiks, R.1    Nathan, A.W.2
  • 31
    • 0018246997 scopus 로고
    • Unusual electrocardiographic pattern during transvenous pacing from the middle cardiac vein
    • Barold S.S., and Banner R. Unusual electrocardiographic pattern during transvenous pacing from the middle cardiac vein. Pacing Clin Electrophysiol 1 (1978) 31-34
    • (1978) Pacing Clin Electrophysiol , vol.1 , pp. 31-34
    • Barold, S.S.1    Banner, R.2
  • 32
    • 20544452338 scopus 로고    scopus 로고
    • An electrocardiogram-based algorithm to detect loss of left ventricular capture during cardiac resynchronization therapy
    • Ammann P., Sticherling C., Kalusche D., et al. An electrocardiogram-based algorithm to detect loss of left ventricular capture during cardiac resynchronization therapy. Ann Intern Med 142 (2005) 968-973
    • (2005) Ann Intern Med , vol.142 , pp. 968-973
    • Ammann, P.1    Sticherling, C.2    Kalusche, D.3
  • 33
    • 0033670410 scopus 로고    scopus 로고
    • A new and reliable method of individual ventricular capture identification during biventricular pacing threshold testing
    • Yong P., and Duby C. A new and reliable method of individual ventricular capture identification during biventricular pacing threshold testing. PACE 23 (2000) 1735-1737
    • (2000) PACE , vol.23 , pp. 1735-1737
    • Yong, P.1    Duby, C.2
  • 34
    • 18444385953 scopus 로고    scopus 로고
    • Specific electrocardiographic patterns may assess left ventricular capture during biventricular pacing
    • [abstract]
    • Georger F., Scavee C., Collet B., et al. Specific electrocardiographic patterns may assess left ventricular capture during biventricular pacing. [abstract]. PACE 25 (2002) 56
    • (2002) PACE , vol.25 , pp. 56
    • Georger, F.1    Scavee, C.2    Collet, B.3
  • 35
    • 1242266256 scopus 로고    scopus 로고
    • Assessment of ventricular capture in patients with cardiac resynchronization devices; a simple surface electrocardiographic algorithm
    • [abstract]
    • Hart D., Luiza P., Arshad R., et al. Assessment of ventricular capture in patients with cardiac resynchronization devices; a simple surface electrocardiographic algorithm. [abstract]. PACE 26 (2003) 1083
    • (2003) PACE , vol.26 , pp. 1083
    • Hart, D.1    Luiza, P.2    Arshad, R.3
  • 36
    • 0037116542 scopus 로고    scopus 로고
    • Retiming the failing heart: principles and current clinical status of cardiac resynchronization
    • Leclercq C., and Kass D.A. Retiming the failing heart: principles and current clinical status of cardiac resynchronization. J Am Coll Cardiol 39 (2002) 194-201
    • (2002) J Am Coll Cardiol , vol.39 , pp. 194-201
    • Leclercq, C.1    Kass, D.A.2
  • 37
    • 0347479206 scopus 로고    scopus 로고
    • Predicting cardiac resynchronization response by QRS duration: the long and short of it
    • Kass D.A. Predicting cardiac resynchronization response by QRS duration: the long and short of it. J Am Coll Cardiol 42 (2003) 2125-2127
    • (2003) J Am Coll Cardiol , vol.42 , pp. 2125-2127
    • Kass, D.A.1
  • 38
    • 0036787663 scopus 로고    scopus 로고
    • Systolic improvement and mechanical resynchronization does not require electrical synchrony in the dilated failing heart with left bundle-branch block
    • Leclercq C., Faris O., Tunin R., et al. Systolic improvement and mechanical resynchronization does not require electrical synchrony in the dilated failing heart with left bundle-branch block. Circulation 106 (2002) 1760-1763
    • (2002) Circulation , vol.106 , pp. 1760-1763
    • Leclercq, C.1    Faris, O.2    Tunin, R.3
  • 39
    • 0242636803 scopus 로고    scopus 로고
    • Biventricular pacing: it isn't always as it seems
    • Kistler P.M., Mond H.G., and Corcoran S.J. Biventricular pacing: it isn't always as it seems. PACE 26 (2003) 2185-2187
    • (2003) PACE , vol.26 , pp. 2185-2187
    • Kistler, P.M.1    Mond, H.G.2    Corcoran, S.J.3
  • 40
    • 16844361841 scopus 로고    scopus 로고
    • Upgrading to triple-ventricular pacing guided by clinical outcomes and echo assessment; a pilot study
    • [abstract]
    • Alonso C., Goscinska K., Ritter P., et al. Upgrading to triple-ventricular pacing guided by clinical outcomes and echo assessment; a pilot study. [abstract]. Europace 6 Suppl 1 (2004) 195
    • (2004) Europace , vol.6 , Issue.SUPPL. 1 , pp. 195
    • Alonso, C.1    Goscinska, K.2    Ritter, P.3
  • 41
    • 0036630489 scopus 로고    scopus 로고
    • Early and late QRS morphology and width in biventricular pacing: relationship to lead site and electrical remodeling
    • Ricci R., Pignalberi C., Ansalone G., et al. Early and late QRS morphology and width in biventricular pacing: relationship to lead site and electrical remodeling. J Interv Card Electrophysiol 6 (2002) 279-285
    • (2002) J Interv Card Electrophysiol , vol.6 , pp. 279-285
    • Ricci, R.1    Pignalberi, C.2    Ansalone, G.3
  • 42
    • 0034952983 scopus 로고    scopus 로고
    • Triple-site ventricular pacing in a biventricular pacing system
    • Van Gelder B.M., Bracke F.A., Pilmeyer A., et al. Triple-site ventricular pacing in a biventricular pacing system. PACE 24 (2001) 1165-1167
    • (2001) PACE , vol.24 , pp. 1165-1167
    • Van Gelder, B.M.1    Bracke, F.A.2    Pilmeyer, A.3
  • 43
    • 1542350214 scopus 로고    scopus 로고
    • Triple-site pacing with biventricular device. Incidence of the phenomenon and cardiac resynchronization benefit
    • Bulava A., Ansalone G., Ricci R., et al. Triple-site pacing with biventricular device. Incidence of the phenomenon and cardiac resynchronization benefit. J Interv Card Electrophysiol 10 (2004) 37-45
    • (2004) J Interv Card Electrophysiol , vol.10 , pp. 37-45
    • Bulava, A.1    Ansalone, G.2    Ricci, R.3
  • 44
    • 0142026260 scopus 로고    scopus 로고
    • Anodal capture with second-generation biventricular cardioverter-defibrillator
    • Herweg B., and Barold S.S. Anodal capture with second-generation biventricular cardioverter-defibrillator. Acta Cardiol 58 (2003) 435-436
    • (2003) Acta Cardiol , vol.58 , pp. 435-436
    • Herweg, B.1    Barold, S.S.2
  • 45
    • 22244431924 scopus 로고    scopus 로고
    • Anodal right ventricular capture during left ventricular stimulation in CRT-implantable cardioverter defibrillators
    • Thibault B., Roy D., Guerra P.G., et al. Anodal right ventricular capture during left ventricular stimulation in CRT-implantable cardioverter defibrillators. Pacing Clin Electrophysiol 28 (2005) 613-619
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 613-619
    • Thibault, B.1    Roy, D.2    Guerra, P.G.3
  • 46
    • 27844470720 scopus 로고    scopus 로고
    • The effect of anodal stimulation on V-V timing at varying V-V intervals
    • van Gelder B.M., Bracke F.A., and Meijer A. The effect of anodal stimulation on V-V timing at varying V-V intervals. Pacing Clin Electrophysiol 28 (2005) 771-776
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 771-776
    • van Gelder, B.M.1    Bracke, F.A.2    Meijer, A.3
  • 47
    • 0033857592 scopus 로고    scopus 로고
    • Treatment of underlying atrial fibrillation: paced rhythm obscures recognition
    • Patel A.M., Westveer D.C., Man K.C., et al. Treatment of underlying atrial fibrillation: paced rhythm obscures recognition. J Am Coll Cardiol 36 (2000) 784-787
    • (2000) J Am Coll Cardiol , vol.36 , pp. 784-787
    • Patel, A.M.1    Westveer, D.C.2    Man, K.C.3
  • 48
    • 0038351180 scopus 로고    scopus 로고
    • Atrial fibrillation in the pacemaker clinic
    • McLellan C.S., Abdollah H., Brennan F.J., et al. Atrial fibrillation in the pacemaker clinic. Can J Cardiol 19 (2003) 492-494
    • (2003) Can J Cardiol , vol.19 , pp. 492-494
    • McLellan, C.S.1    Abdollah, H.2    Brennan, F.J.3
  • 49
    • 0031839307 scopus 로고    scopus 로고
    • Atrial fibrillation and anticoagulation in patients with permanent pacemakers: implications for stroke prevention
    • Sparks P.B., Mond H.G., Kalman J.M., et al. Atrial fibrillation and anticoagulation in patients with permanent pacemakers: implications for stroke prevention. Pacing Clin Electrophysiol 21 (1998) 1258-1267
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 1258-1267
    • Sparks, P.B.1    Mond, H.G.2    Kalman, J.M.3
  • 50
    • 0031989438 scopus 로고    scopus 로고
    • Therapeutic options in patients with obstructive hypertrophic cardiomyopathyand severe drug-refractory symptoms
    • Fananapazir L., and McAreavey D. Therapeutic options in patients with obstructive hypertrophic cardiomyopathyand severe drug-refractory symptoms. J Am Coll Cardiol 31 (1998) 259-264
    • (1998) J Am Coll Cardiol , vol.31 , pp. 259-264
    • Fananapazir, L.1    McAreavey, D.2
  • 53
    • 1842843856 scopus 로고    scopus 로고
    • Intra- and interatrial conduction delay: implications for cardiac pacing
    • Daubert J.C., Pavin D., Jauvert G., et al. Intra- and interatrial conduction delay: implications for cardiac pacing. PACE 27 (2004) 507-525
    • (2004) PACE , vol.27 , pp. 507-525
    • Daubert, J.C.1    Pavin, D.2    Jauvert, G.3
  • 54
    • 0033667229 scopus 로고    scopus 로고
    • DDD pacing and interatrial conduction block:importance of optimal interval setting
    • Parravicimi U., Mezzani A., Bielli M., et al. DDD pacing and interatrial conduction block:importance of optimal interval setting. PACE 23 (2000) 1448-1450
    • (2000) PACE , vol.23 , pp. 1448-1450
    • Parravicimi, U.1    Mezzani, A.2    Bielli, M.3
  • 55
    • 0033770750 scopus 로고    scopus 로고
    • Long-term effects of biatrial synchronous pacing to prevent drug-refractory atrial tachyarrhythmia: a nine-year experience
    • D'Allones G.R., Pavin D., Leclercq C., et al. Long-term effects of biatrial synchronous pacing to prevent drug-refractory atrial tachyarrhythmia: a nine-year experience. J Cardiovasc Electrophysiol 11 (2000) 1081-1091
    • (2000) J Cardiovasc Electrophysiol , vol.11 , pp. 1081-1091
    • D'Allones, G.R.1    Pavin, D.2    Leclercq, C.3
  • 57
    • 0017144936 scopus 로고
    • The Wenckebach phenomenon between electric pacemaker and ventricle
    • Klein H.O., Di Segni E., Kaplinsky E., et al. The Wenckebach phenomenon between electric pacemaker and ventricle. Br Heart J 38 (1976) 961-965
    • (1976) Br Heart J , vol.38 , pp. 961-965
    • Klein, H.O.1    Di Segni, E.2    Kaplinsky, E.3
  • 58
    • 0017285928 scopus 로고
    • Wenckebach phenomenon in the exit area from a transvenous pacing electrode
    • Peter T., Harper R., Hunt D., et al. Wenckebach phenomenon in the exit area from a transvenous pacing electrode. Br Heart J 38 (1976) 201-352
    • (1976) Br Heart J , vol.38 , pp. 201-352
    • Peter, T.1    Harper, R.2    Hunt, D.3
  • 59
    • 0017060370 scopus 로고
    • Pacemaker Wenckebach phenomenon due to antiarrhythmic drug toxicity
    • Mehta J., and Khan A.H. Pacemaker Wenckebach phenomenon due to antiarrhythmic drug toxicity. Cardiology 61 3 (1976) 189-194
    • (1976) Cardiology , vol.61 , Issue.3 , pp. 189-194
    • Mehta, J.1    Khan, A.H.2
  • 60
    • 0023262113 scopus 로고
    • Pacemaker Wenckebach secondary to variable latency: an unusual form of hyperkalemic pacemaker exit block
    • Varriale P., and Manolis A. Pacemaker Wenckebach secondary to variable latency: an unusual form of hyperkalemic pacemaker exit block. Am Heart J 114 (1987) 189-192
    • (1987) Am Heart J , vol.114 , pp. 189-192
    • Varriale, P.1    Manolis, A.2
  • 61
    • 0031685076 scopus 로고    scopus 로고
    • Loss of atrial capture during DDD pacing: what is the mechanism?
    • Barold S.S. Loss of atrial capture during DDD pacing: what is the mechanism?. Pacing Clin Electrophysiol 21 (1998) 1988-1989
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 1988-1989
    • Barold, S.S.1
  • 62
    • 0023195982 scopus 로고
    • Hyperkalemia-induced failure of atrial capture during dual-chamber cardiac pacing
    • Barold S.S., Falkoff M.D., Ong L.S., et al. Hyperkalemia-induced failure of atrial capture during dual-chamber cardiac pacing. J Am Coll Cardiol 10 (1987) 467-469
    • (1987) J Am Coll Cardiol , vol.10 , pp. 467-469
    • Barold, S.S.1    Falkoff, M.D.2    Ong, L.S.3
  • 63
    • 3142691894 scopus 로고    scopus 로고
    • Hyperkalaemia causing loss of atrial capture and extremely wide QRS complex during DDD pacing
    • Ortega-Carnicer J., Benezet J., and Benezet-Mazuecos J. Hyperkalaemia causing loss of atrial capture and extremely wide QRS complex during DDD pacing. Resuscitation 62 (2004) 119-120
    • (2004) Resuscitation , vol.62 , pp. 119-120
    • Ortega-Carnicer, J.1    Benezet, J.2    Benezet-Mazuecos, J.3
  • 64
    • 0023262113 scopus 로고
    • Pacemaker Wenckebach secondary to variable latency: an unusual form of hyperkalemic pacemaker exit block
    • Varriale P., and Manolis A. Pacemaker Wenckebach secondary to variable latency: an unusual form of hyperkalemic pacemaker exit block. Am Heart J 114 (1987) 189-192
    • (1987) Am Heart J , vol.114 , pp. 189-192
    • Varriale, P.1    Manolis, A.2
  • 65
    • 0022159285 scopus 로고
    • Myocardial stimulation threshold in patients with cardiac pacemakers: effect of physiologic variables, pharmacologic agents, and lead electrodes
    • Dohrmann M.L., and Goldschlager N.F. Myocardial stimulation threshold in patients with cardiac pacemakers: effect of physiologic variables, pharmacologic agents, and lead electrodes. Cardiol Clin 3 (1985) 527-537
    • (1985) Cardiol Clin , vol.3 , pp. 527-537
    • Dohrmann, M.L.1    Goldschlager, N.F.2
  • 66
    • 18844411372 scopus 로고    scopus 로고
    • Association of prolonged QRS duration with death in a clinical trial of pacemaker therapy for sinus node dysfunction
    • Sweeney M.O., Hellkamp A.S., Lee K.L., Mode Selection Trial (MOST) Investigators, et al. Association of prolonged QRS duration with death in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation 111 (2005) 2418-2423
    • (2005) Circulation , vol.111 , pp. 2418-2423
    • Sweeney, M.O.1    Hellkamp, A.S.2    Lee, K.L.3    Mode Selection Trial (MOST) Investigators4
  • 67
    • 33644846765 scopus 로고    scopus 로고
    • Prolonged paced QRS duration as a predictor for congestive heart failure in patients with right ventricular apical pacing
    • Miyoshi F., Kobayashi Y., Itou H., et al. Prolonged paced QRS duration as a predictor for congestive heart failure in patients with right ventricular apical pacing. Pacing Clin Electrophysiol 28 (2005) 1182-1188
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 1182-1188
    • Miyoshi, F.1    Kobayashi, Y.2    Itou, H.3
  • 68
    • 0036710643 scopus 로고    scopus 로고
    • The DVI mode of cardiac pacing: a second coming?
    • Barold S.S., Gallardo I., and Sayad D. The DVI mode of cardiac pacing: a second coming?. Am J Cardiol 90 (2002) 521-523
    • (2002) Am J Cardiol , vol.90 , pp. 521-523
    • Barold, S.S.1    Gallardo, I.2    Sayad, D.3
  • 69
    • 0036665168 scopus 로고    scopus 로고
    • Triboelectric simulation of pacemaker malfunction
    • Kahan S., Miller C.W., Hayes D.L., et al. Triboelectric simulation of pacemaker malfunction. Europace 4 (2002) 325-327
    • (2002) Europace , vol.4 , pp. 325-327
    • Kahan, S.1    Miller, C.W.2    Hayes, D.L.3
  • 70
    • 84921440114 scopus 로고    scopus 로고
    • Images is cardiology: initiation of pacemaker endless loop tachycardia by triboelectricity
    • Barold S.S. Images is cardiology: initiation of pacemaker endless loop tachycardia by triboelectricity. Heart 85 (2001) 248
    • (2001) Heart , vol.85 , pp. 248
    • Barold, S.S.1
  • 71
    • 0012521257 scopus 로고
    • Differential diagnosis of pacemaker pauses
    • Barold S.S. (Ed), Futura, Mt Kisco (NY)
    • Barold S.S., Falkoff M.D., Ong L.S., et al. Differential diagnosis of pacemaker pauses. In: Barold S.S. (Ed). Modern cardiac pacing (1985), Futura, Mt Kisco (NY) 587-613
    • (1985) Modern cardiac pacing , pp. 587-613
    • Barold, S.S.1    Falkoff, M.D.2    Ong, L.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.