메뉴 건너뛰기




Volumn 72, Issue 8, 2006, Pages 728-732

Impedance cardiography: Can it replace thermodilution and the pulmonary artery catheter?

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BODY MASS; CLINICAL ASSESSMENT; COMPARATIVE STUDY; CONTROLLED STUDY; CORRELATION ANALYSIS; DEVICE; DIAGNOSTIC ACCURACY; FEMALE; HEART ASSIST DEVICE; HEART OUTPUT; HEMODYNAMICS; HUMAN; IMPEDANCE CARDIOGRAPHY; INTENSIVE CARE; INTENSIVE CARE UNIT; LENGTH OF STAY; MAJOR CLINICAL STUDY; MALE; PATIENT POSITIONING; PHYSICIAN; PROSPECTIVE STUDY; PULMONARY ARTERY CATHETER; PULMONARY ASSIST DEVICE; RANDOMIZATION; THERMODILUTION; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CRITICAL ILLNESS; FOLLOW UP; HEART DISEASE; METHODOLOGY; MIDDLE AGED; PATHOPHYSIOLOGY; PHYSIOLOGY; RANDOMIZED CONTROLLED TRIAL; REPRODUCIBILITY; SWAN GANZ CATHETER;

EID: 33747828689     PISSN: 00031348     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (10)

References (18)
  • 1
    • 0024497513 scopus 로고
    • The limited reliability of physical signs for estimating hemodynamics in chronic heart failure
    • Stevenson LW, Perloff JK. The limited reliability of physical signs for estimating hemodynamics in chronic heart failure. J Am Med Assoc 1989;261:884-8.
    • (1989) J Am Med Assoc , vol.261 , pp. 884-888
    • Stevenson, L.W.1    Perloff, J.K.2
  • 2
    • 27744519271 scopus 로고    scopus 로고
    • Hemodynamic and pulmonary fluid status in the trauma patient: Are we slipping?
    • Veale WN Jr, Morgan JH, Beatty JS, et al. Hemodynamic and pulmonary fluid status in the trauma patient: Are we slipping? Am Surg 2005;71:621-6.
    • (2005) Am Surg , vol.71 , pp. 621-626
    • Veale Jr, W.N.1    Morgan, J.H.2    Beatty, J.S.3
  • 3
    • 22244436230 scopus 로고    scopus 로고
    • Cardiopulmonary assessment: Is improvement needed?
    • Van De Water JM, Dalton ML, Parish DC, et al. Cardiopulmonary assessment: Is improvement needed? World J Surg 2005;29(Suppl 1):S95-8.
    • (2005) World J Surg , vol.29 , Issue.SUPPL. 1
    • Van De Water, J.M.1    Dalton, M.L.2    Parish, D.C.3
  • 4
    • 0037413466 scopus 로고    scopus 로고
    • Canadian Critical Care Clinical Trials Group. A randomized, controlled trial of the use of pulmonary artery catheters in high-risk surgical patients
    • Sandham JD, Hull RD, Brant RF, et al. Canadian Critical Care Clinical Trials Group. A randomized, controlled trial of the use of pulmonary artery catheters in high-risk surgical patients. N Engl J Med 2003;348:5-14.
    • (2003) N Engl J Med , vol.348 , pp. 5-14
    • Sandham, J.D.1    Hull, R.D.2    Brant, R.F.3
  • 5
    • 0345374592 scopus 로고    scopus 로고
    • French Pulmonary Artery Catheter Study Group. Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: A randomized controlled trial
    • Richard C, Warszawski J, Anguel N, et al. French Pulmonary Artery Catheter Study Group. Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: A randomized controlled trial. J Am Med Assoc 2003;290:2713-20.
    • (2003) J Am Med Assoc , vol.290 , pp. 2713-2720
    • Richard, C.1    Warszawski, J.2    Anguel, N.3
  • 6
    • 45249090603 scopus 로고    scopus 로고
    • Burchard KW. Shock. In: Lawrence PF, Bell RM, Dayton MT, eds. Essentials of General Surgery, 3rd ed. Philadelphia: Lippincott Williams & Wilkins, 2000, pp 93-112.
    • Burchard KW. Shock. In: Lawrence PF, Bell RM, Dayton MT, eds. Essentials of General Surgery, 3rd ed. Philadelphia: Lippincott Williams & Wilkins, 2000, pp 93-112.
  • 7
    • 45249105961 scopus 로고    scopus 로고
    • Shock: Approach to the treatment of shock
    • DW Wilmore, et al, eds, New York: WebMD Corp
    • Holcroft JW. Shock: Approach to the treatment of shock. In: DW Wilmore, et al., eds. ACS Surgery: Principles and Practice 2003. New York: WebMD Corp., 2003, pp 63-76.
    • (2003) ACS Surgery: Principles and Practice 2003 , pp. 63-76
    • Holcroft, J.W.1
  • 8
    • 14944350322 scopus 로고    scopus 로고
    • Thoracic fluid content (TFC): A new parameter for assessment of changes in chest fluid volume
    • Van De Water JM, Mount BE, Chandra KM, et al. Thoracic fluid content (TFC): A new parameter for assessment of changes in chest fluid volume. Am Surg 2005;71:81-6.
    • (2005) Am Surg , vol.71 , pp. 81-86
    • Van De Water, J.M.1    Mount, B.E.2    Chandra, K.M.3
  • 9
    • 45249113714 scopus 로고    scopus 로고
    • BioZ.com. Operators' Manual. San Diego, CA: Cardio Dynamics Int. Corp., 2001.
    • BioZ.com. Operators' Manual. San Diego, CA: Cardio Dynamics Int. Corp., 2001.
  • 10
    • 45249120383 scopus 로고    scopus 로고
    • American College of Surgeons Committee on Trauma. Shock. In: Krantz BE, Weigelt JA, Ali J, Aprahamian C, Bell RM, Boyle DE, Collicott PE, Feliciano DV, Jurkovich GJ, Kellam JF, Maull KI, McManus WF, Morris JA, Parks SN, Narayan R, Ramenofsky ML, Reynolds SA, Rinker C, Timberlake GA, eds. Advanced Trauma Life Support Program for Doctors: ATLS, 6th ed. Chicago: American College of Surgeons, 1997, 97-146.
    • American College of Surgeons Committee on Trauma. Shock. In: Krantz BE, Weigelt JA, Ali J, Aprahamian C, Bell RM, Boyle DE, Collicott PE, Feliciano DV, Jurkovich GJ, Kellam JF, Maull KI, McManus WF, Morris JA, Parks SN, Narayan R, Ramenofsky ML, Reynolds SA, Rinker C, Timberlake GA, eds. Advanced Trauma Life Support Program for Doctors: ATLS, 6th ed. Chicago: American College of Surgeons, 1997, 97-146.
  • 11
    • 0001575491 scopus 로고    scopus 로고
    • Comparison of cardiac output measurements by thoracic electrical bioimpedance versus intermittent bolus thermodilution in mechanical ventilated patients
    • Ziegler D, Grotti L, Krucke G. Comparison of cardiac output measurements by thoracic electrical bioimpedance versus intermittent bolus thermodilution in mechanical ventilated patients. Chest 1999;116:281S.
    • (1999) Chest , vol.116
    • Ziegler, D.1    Grotti, L.2    Krucke, G.3
  • 12
    • 0037090669 scopus 로고    scopus 로고
    • Comparison of impedance cardiography with invasive hemodynamic measurements in patients with heart failure secondary to ischemic or nonischemic cardiomyopathy
    • Drazner MH, Thompson B, Rosenberg PB, et al. Comparison of impedance cardiography with invasive hemodynamic measurements in patients with heart failure secondary to ischemic or nonischemic cardiomyopathy. Am J Cardiol 2002;89:993-5.
    • (2002) Am J Cardiol , vol.89 , pp. 993-995
    • Drazner, M.H.1    Thompson, B.2    Rosenberg, P.B.3
  • 13
    • 0036171177 scopus 로고    scopus 로고
    • Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery
    • Sageman WS, Riffenburgh RH, Spiess BD. Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery. J Cardiothorac Vasc Anesth 2002;16:8-14.
    • (2002) J Cardiothorac Vasc Anesth , vol.16 , pp. 8-14
    • Sageman, W.S.1    Riffenburgh, R.H.2    Spiess, B.D.3
  • 14
    • 0038385882 scopus 로고    scopus 로고
    • Impedance cardiography: The next vital sign technology?
    • Van De Water JM, Miller TW, Vogel RL, et al. Impedance cardiography: The next vital sign technology? Chest 2003;123: 2028-33.
    • (2003) Chest , vol.123 , pp. 2028-2033
    • Van De Water, J.M.1    Miller, T.W.2    Vogel, R.L.3
  • 15
    • 8644266685 scopus 로고    scopus 로고
    • Equivalence of the bioimpedance and thermodilution methods in measuring cardiac output in hospitalized patients with advanced, decompensated chronic heart failure
    • Albert NM, Hail MD, Li J, et al. Equivalence of the bioimpedance and thermodilution methods in measuring cardiac output in hospitalized patients with advanced, decompensated chronic heart failure. Am J Crit Care 2004;13:469-79.
    • (2004) Am J Crit Care , vol.13 , pp. 469-479
    • Albert, N.M.1    Hail, M.D.2    Li, J.3
  • 16
    • 3042738343 scopus 로고    scopus 로고
    • Comparison of impedance cardiography to direct Fick and thermodilution cardiac output determinations in pulmonary artery hypertension
    • Yung GL, Fedullo PF, Kinninger K, et al. Comparison of impedance cardiography to direct Fick and thermodilution cardiac output determinations in pulmonary artery hypertension. Congest Heart Fail 2004;10(Suppl 2):7-10.
    • (2004) Congest Heart Fail , vol.10 , Issue.SUPPL. 2 , pp. 7-10
    • Yung, G.L.1    Fedullo, P.F.2    Kinninger, K.3
  • 17
    • 18044389302 scopus 로고    scopus 로고
    • The effect of obesity on bioimpedance cardiac index
    • Brown CV, Martin MJ, Shoemaker WC, et al. The effect of obesity on bioimpedance cardiac index. Am J Surg 2005;189: 547-51.
    • (2005) Am J Surg , vol.189 , pp. 547-551
    • Brown, C.V.1    Martin, M.J.2    Shoemaker, W.C.3
  • 18
    • 14544286527 scopus 로고    scopus 로고
    • Is noninvasive hemodynamic monitoring appropriate for the elderly critically injured patient?
    • Brown CV, Shoemaker WC, Wo CC, et al. Is noninvasive hemodynamic monitoring appropriate for the elderly critically injured patient? J Trauma 2005;58:102-7.
    • (2005) J Trauma , vol.58 , pp. 102-107
    • Brown, C.V.1    Shoemaker, W.C.2    Wo, C.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.