메뉴 건너뛰기




Volumn 64, Issue 11, 2006, Pages 744-751

Test methodology to evaluate the safety of materials using spark incendivity

Author keywords

Corona discharge; Electrostatic hazards; Ignition; Safety; Spark incendivity; Surface resistivity; Triboelectricity

Indexed keywords

ELECTRIC CONDUCTIVITY; ELECTRIC SPARKS; FLAMMABLE MATERIALS; IGNITION; SAFETY TESTING; TRIBOELECTRICITY;

EID: 33747757509     PISSN: 03043886     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.elstat.2006.04.001     Document Type: Article
Times cited : (9)

References (12)
  • 1
    • 33747770383 scopus 로고    scopus 로고
    • A. Finchum, Standard Test Method for Evaluating Triboelectric Charge Generation and Decay, KSC Test Standard MMA-1985-98, Revision 3, 1998.
  • 2
    • 33747772803 scopus 로고    scopus 로고
    • D.M. Taylor, J. Elias, A versatile charge decay meter for assessing antistatic materials, Institute of Physics Conference Series No. 85, Section 2, Electrostatics '87, Oxford, 1987.
  • 3
    • 33747754863 scopus 로고    scopus 로고
    • S. Fowler, Surface Resistivity and Static Decay Do Not Correlate, Proceedings of EOS/ESD Symposium, 1989, p. 7.
  • 4
    • 33747776217 scopus 로고    scopus 로고
    • International Electrotechnical Commission, Part 4-4: standard test methods for specific applications-electrostatic classification of flexible intermediate bulk containers (FIBC), IEC 61340-4-4:2005, 2005.
  • 5
    • 33747749940 scopus 로고    scopus 로고
    • ESD Association Standard Test Method ESD STM11.11, Surface Resistance Measurements of Static Dissipative Planar Materials, 2001.
  • 6
    • 33747795020 scopus 로고    scopus 로고
    • British Standard BS 7506, Methods for Measurments in Electrostatics, Part 2, 1995.
  • 7
    • 0034315119 scopus 로고    scopus 로고
    • Measurement of Tribo and Corona charging features of materials for assessment of risks from static electricity
    • Chubb J. Measurement of Tribo and Corona charging features of materials for assessment of risks from static electricity. IEEE Trans. Ind. Appl. 36 6 (2000)
    • (2000) IEEE Trans. Ind. Appl. , vol.36 , Issue.6
    • Chubb, J.1
  • 8
    • 33747795344 scopus 로고    scopus 로고
    • C.R. Buhler, C.I. Calle, Electrostatic Evaluation of the STS Thermal Control System Multilayer Insulation Blankets, NASA/TM-2004-211521, 2004.
  • 9
    • 33747802142 scopus 로고    scopus 로고
    • C.R. Buhler, C.I. Calle, Final Results of the Electrostatic Evaluation of the STS Thermal Control System Multi-Layer Insulation Blankets, NASA/TM 2005-211542, 2005.
  • 10
    • 33747781843 scopus 로고    scopus 로고
    • C.R. Buhler, C.I. Calle, Results of the Electrostatic Evaluation of the ISS Thermal Shrouds and the ISS Multi-Layer Insulation Blankets, NASA/TM 2005-211541, 2005.
  • 11
    • 33747782201 scopus 로고    scopus 로고
    • R. Gomph, P. Holdstock, J.N. Chubb, Electrostatic Test Methods Compared, EOS/ESD Symposium, September 26-30, 1999.
  • 12
    • 0020950177 scopus 로고    scopus 로고
    • G.J. Butterworth, E.S. Paul, J.N. Chubb, A study of the incendivity of electrical discharges between planar resistive electrodes, 'Electrostatics 1983', IoP Conference Series, 66, 1983, p. 185.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.