Volumn 21, Issue 3, 2006, Pages 1321-1330

Effect of coordination of optimal reclosing and fuzzy controlled braking resistor on transient stability during unsuccessful reclosing

Author keywords

Balanced fault; Braking resistor (BR); Fuzzy controller; Global positioning system (GPS); Optimal reclosing; Power system transient stability; Unbalanced faults; Unsuccessful reclosing

Indexed keywords

COMPUTER SIMULATION; ELECTRIC FAULT CURRENTS; FUZZY CONTROL; GLOBAL POSITIONING SYSTEM; OPTIMIZATION; RECLOSING CIRCUIT BREAKERS; RESISTORS;

EID: 33747617574     PISSN: 08858950     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRS.2006.876670     Document Type: Article
Times cited : (33)

References (24)
  • 1
    • 0029386395 scopus 로고
    • "Fuzzy logic switching of thyristor controlled braking resistor considering coordination with SVC"
    • Oct
    • T. Hiyama, M. Mishiro, H. Kihara, and T. H. Ortmeyer, "Fuzzy logic switching of thyristor controlled braking resistor considering coordination with SVC," IEEE Trans. Power Del., vol. 10, no. 4, pp. 2020-2026, Oct. 1995.
    • (1995) IEEE Trans. Power Del. , vol.10 , Issue.4 , pp. 2020-2026
    • Hiyama, T.1    Mishiro, M.2    Kihara, H.3    Ortmeyer, T.H.4
  • 2
    • 0009934684 scopus 로고
    • "Fuzzy logic switching control of braking resistor and shunt reactor for stability enhancement of multimachine power system"
    • T. Hiyama, T. Sameshima, and C. M. Lim, "Fuzzy logic switching control of braking resistor and shunt reactor for stability enhancement of multimachine power system," in Proc. Int. Conf. Automation, Robotics, Computer Vision, 1990, pp. 695-699.
    • (1990) Proc. Int. Conf. Automation, Robotics, Computer Vision , pp. 695-699
    • Hiyama, T.1    Sameshima, T.2    Lim, C.M.3
  • 3
    • 10244247756 scopus 로고    scopus 로고
    • "Multilayer fuzzy controller for control of power networks"
    • Nov./Dec
    • A. Rubaai and A. R. Ofoli, "Multilayer fuzzy controller for control of power networks," IEEE Trans. Ind. Appl., vol.40, no. 6, pp. 1521-1528, Nov./Dec. 2004.
    • (2004) IEEE Trans. Ind. Appl. , vol.40 , Issue.6 , pp. 1521-1528
    • Rubaai, A.1    Ofoli, A.R.2
  • 6
    • 84886817747 scopus 로고    scopus 로고
    • "A fuzzy logic controlled braking resistor scheme for stabilization of synchronous generator"
    • M. H. Ali, Y. Soma, T. Murata, and J. Tamura, "A fuzzy logic controlled braking resistor scheme for stabilization of synchronous generator," in Proc. IEEE Int. Electric Machines Drives Conf., 2001, pp. 548-550.
    • (2001) Proc. IEEE Int. Electric Machines Drives Conf. , pp. 548-550
    • Ali, M.H.1    Soma, Y.2    Murata, T.3    Tamura, J.4
  • 8
    • 2542580157 scopus 로고    scopus 로고
    • "The effect of temperature rise of the fuzzy logic-controlled braking resistors on transient stability"
    • May
    • M. H. Ali, T. Murata, and J. Tamura, "The effect of temperature rise of the fuzzy logic-controlled braking resistors on transient stability," IEEE Trans. Power Syst., vol. 19, no. 2, pp. 1085-1095, May 2004.
    • (2004) IEEE Trans. Power Syst. , vol.19 , Issue.2 , pp. 1085-1095
    • Ali, M.H.1    Murata, T.2    Tamura, J.3
  • 10
    • 51549093578 scopus 로고    scopus 로고
    • "Augmentation of transient stability by fuzzy-logic controlled braking resistor in multi-machine power system"
    • M. H. Ali, T. Murata, and J. Tamura, "Augmentation of transient stability by fuzzy-logic controlled braking resistor in multi-machine power system," in Proc. IEEE PowerTech Conf., 2005, 61.
    • (2005) Proc. IEEE PowerTech Conf. , pp. 61
    • Ali, M.H.1    Murata, T.2    Tamura, J.3
  • 11
    • 26944476663 scopus 로고    scopus 로고
    • "Transient stability improvement by fuzzy logic controlled braking resistor"
    • M. H. Ali, Y. Soma, T. Murata, and J. Tamura, "Transient stability improvement by fuzzy logic controlled braking resistor," Int. J. Power Energy Syst., vol. 25, no. 3, pp. 143-150, 2005.
    • (2005) Int. J. Power Energy Syst. , vol.25 , Issue.3 , pp. 143-150
    • Ali, M.H.1    Soma, Y.2    Murata, T.3    Tamura, J.4
  • 13
    • 1942519812 scopus 로고    scopus 로고
    • "An analysis of optimal reclosing for enhancement of transient stability"
    • M. Yagami, T. Murata, and J. Tamura, "An analysis of optimal reclosing for enhancement of transient stability," Elect. Eng. Jpn., vol. 147, no. 3, pp. 32-39, 2004.
    • (2004) Elect. Eng. Jpn. , vol.147 , Issue.3 , pp. 32-39
    • Yagami, M.1    Murata, T.2    Tamura, J.3
  • 16
    • 0006295773 scopus 로고
    • "The design and application of an optimal reclosure technique for transmission lines"
    • in Bozeman, MT: Montana State Univ
    • B. H. Zhang, Z. Q. Bo, Y. Z. Ge, R. K. Aggarwal, and A. T. Johns, "The design and application of an optimal reclosure technique for transmission lines," in 1995 North American Power Symposium. Bozeman, MT: Montana State Univ., 1995, pp. 415-421.
    • (1995) 1995 North American Power Symposium , pp. 415-421
    • Zhang, B.H.1    Bo, Z.Q.2    Ge, Y.Z.3    Aggarwal, R.K.4    Johns, A.T.5
  • 18
    • 33747620972 scopus 로고    scopus 로고
    • Japan EMTP Committee
    • EMTP Theory Book, Japan EMTP Committee.
    • EMTP Theory Book
  • 19
    • 0031677665 scopus 로고    scopus 로고
    • "IEEE standard for synchrophasors for power systems"
    • Working Group H-8 of the Relay Communications Subcommittee of the IEEE Power System Relaying Committee, Jan
    • Working Group H-8 of the Relay Communications Subcommittee of the IEEE Power System Relaying Committee, "IEEE standard for synchrophasors for power systems," IEEE Trans. Power Del., vol. 13, no. 1, pp. 73-77, Jan. 1998.
    • (1998) IEEE Trans. Power Del. , vol.13 , Issue.1 , pp. 73-77
  • 20
    • 0031177541 scopus 로고    scopus 로고
    • "A new type of differential feeder protection relay using the global positioning system for data synchronization"
    • Jul
    • H. Y. Li, E. P. Southern, P. A. Crossley, S. Potts, S. D. A. Pickering, B. R. J. Caunce, and G. C. Weller, "A new type of differential feeder protection relay using the global positioning system for data synchronization," IEEE Trans. Power Del., vol. 12, no. 3, pp. 73-77, Jul. 1997.
    • (1997) IEEE Trans. Power Del. , vol.12 , Issue.3 , pp. 73-77
    • Li, H.Y.1    Southern, E.P.2    Crossley, P.A.3    Potts, S.4    Pickering, S.D.A.5    Caunce, B.R.J.6    Weller, G.C.7
  • 21
    • 0026626422 scopus 로고
    • "Methods and uses of precise time in power systems"
    • Jan
    • R. E. Wilson, "Methods and uses of precise time in power systems," IEEE Trans. Power Del., vol. 7, no. 1, pp. 126-131, Jan. 1992.
    • (1992) IEEE Trans. Power Del. , vol.7 , Issue.1 , pp. 126-131
    • Wilson, R.E.1
  • 22
    • 0027631951 scopus 로고
    • "An investigation of time transfer accuracies over a utility microwave communications channel"
    • Jul
    • R. E. Wilson, "An investigation of time transfer accuracies over a utility microwave communications channel," IEEE Trans. Power Del., vol. 8, no. 3, pp. 993-999, Jul. 1993.
    • (1993) IEEE Trans. Power Del. , vol.8 , Issue.3 , pp. 993-999
    • Wilson, R.E.1
  • 23
    • 0028196385 scopus 로고
    • "Synchronized sampling and phasor measurements for relaying and control"
    • Working Group H-7 of the Relaying Channels Subcommittee of the IEEE Power System Relaying Committee, Jan
    • Working Group H-7 of the Relaying Channels Subcommittee of the IEEE Power System Relaying Committee, "Synchronized sampling and phasor measurements for relaying and control," IEEE Trans. Power Del., vol. 9, no. 1, pp. 442-452, Jan. 1994.
    • (1994) IEEE Trans. Power Del. , vol.9 , Issue.1 , pp. 442-452


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.