메뉴 건너뛰기




Volumn 61, Issue 2, 2006, Pages 457-460

Closed antegrade interlocked nailing of femoral shaft fractures operated up to 2 weeks postinjury in the absence of a fracture table or C-arm

Author keywords

C arm; Closed; Femur; Fracture table; Nailing

Indexed keywords

ARTICLE; C ARM; CLOSED ANTEGRADE INTERLOCKED NAILING; FEMALE; FEMUR FRACTURE; FEMUR SHAFT FRACTURE; FOLLOW UP; FRACTURE TABLE; GAIT; HUMAN; HUMAN TISSUE; INTRAMEDULLARY NAILING; JOINT MOBILITY; MAJOR CLINICAL STUDY; MALE; MUSCLE SPASM; OPERATION DURATION; PRIORITY JOURNAL; SKELETON TRACTION; SOUNDING TECHNIQUE; SURGICAL EQUIPMENT; SURGICAL RISK; SURGICAL TECHNIQUE; TANNA TECHNIQUE; TREATMENT OUTCOME;

EID: 33747601088     PISSN: 00225282     EISSN: 15298809     Source Type: Journal    
DOI: 10.1097/01.ta.0000210269.05305.75     Document Type: Article
Times cited : (14)

References (12)
  • 1
    • 0025981098 scopus 로고
    • Locked intramedullary nailing of femoral shaft fractures
    • Alho A, Stromsoe K, Ekeland A. Locked intramedullary nailing of femoral shaft fractures. J Trauma. 1991;31:49-59.
    • (1991) J Trauma , vol.31 , pp. 49-59
    • Alho, A.1    Stromsoe, K.2    Ekeland, A.3
  • 2
    • 0027420820 scopus 로고
    • Closed interlocking nailing in comminuted segmental femoral shaft fractures
    • Anastopoulas G, Asimakopoulos A, Exarchov E, Pantazopoulous T. Closed interlocking nailing in comminuted segmental femoral shaft fractures. J Trauma. 1993;35:772-775.
    • (1993) J Trauma , vol.35 , pp. 772-775
    • Anastopoulas, G.1    Asimakopoulos, A.2    Exarchov, E.3    Pantazopoulous, T.4
  • 3
    • 0014332127 scopus 로고
    • Closed intramedullary nailing of the femur
    • Bohler J. Closed intramedullary nailing of the femur. Clin Orthop. 1968;60:51-67.
    • (1968) Clin Orthop , vol.60 , pp. 51-67
    • Bohler, J.1
  • 4
    • 0022506671 scopus 로고
    • Biomechanical performance of locked intramedullary nail systems in comminuted femoral shaft fractures
    • Johnson KD, Tencer AF, Blumenthal S, August A, Johnston, D.W.C. Biomechanical performance of locked intramedullary nail systems in comminuted femoral shaft fractures. Clin Orthop. 1986;206:151-161.
    • (1986) Clin Orthop , vol.206 , pp. 151-161
    • Johnson, K.D.1    Tencer, A.F.2    Blumenthal, S.3    August, A.4    Johnston, D.W.C.5
  • 5
    • 0021885423 scopus 로고
    • Closed locked intramedullary nailing
    • Kempf I, Grosse A, Beck G. Closed locked intramedullary nailing. J Bone Joint Surg. 1985;67A:709-720.
    • (1985) J Bone Joint Surg , vol.67 A , pp. 709-720
    • Kempf, I.1    Grosse, A.2    Beck, G.3
  • 6
    • 0036712408 scopus 로고    scopus 로고
    • Femoral intramedullary nailing: Comparison of fracture table and manual traction. A prospective randomized study
    • David JGS. Femoral intramedullary nailing: comparison of fracture table and manual traction. A prospective randomized study. JBJS. 2002;84A:1514-1521.
    • (2002) JBJS , vol.84 A , pp. 1514-1521
    • David, J.G.S.1
  • 7
    • 0024600557 scopus 로고
    • Early Versus Delayed Stabilization of Femoral Fractures. A Prospective Randomized Study
    • Bone LB, Johnson KD, Weigelt J, Scheinberg R. Early Versus Delayed Stabilization of Femoral Fractures. A Prospective Randomized Study. J Bone Joint Surg. 1989;71A:336-340.
    • (1989) J Bone Joint Surg , vol.71 A , pp. 336-340
    • Bone, L.B.1    Johnson, K.D.2    Weigelt, J.3    Scheinberg, R.4
  • 8
    • 0028244467 scopus 로고
    • Brief reports. Interlocking tibial nailing without image intensifier
    • Tanna DD. Brief reports. Interlocking tibial nailing without image intensifier. JBJS. 1994;76B:670.
    • (1994) JBJS , vol.76 B , pp. 670
    • Tanna, D.D.1
  • 9
    • 0028224489 scopus 로고
    • Compartment syndrome in the well leg resulting from fracture table positioning
    • Anglan J, Banoveta J. Compartment syndrome in the well leg resulting from fracture table positioning. CORR. 1994;301:239-242.
    • (1994) CORR , vol.301 , pp. 239-242
    • Anglan, J.1    Banoveta, J.2
  • 10
    • 0028097452 scopus 로고
    • Perineal sloughing as a result of pressure necrosis from the traction post during prolonged bilateral femoral nailing
    • Callanan I, Choundhry V, Smith H. Perineal sloughing as a result of pressure necrosis from the traction post during prolonged bilateral femoral nailing. Injury. 1994;24:472.
    • (1994) Injury , vol.24 , pp. 472
    • Callanan, I.1    Choundhry, V.2    Smith, H.3
  • 11
    • 0027082730 scopus 로고
    • Pudendal nerve palsy complicating intramedullary nailing of the femur
    • Brumback RJ, Ellison TS, Molligan H, et al. Pudendal nerve palsy complicating intramedullary nailing of the femur. J Bone Joint Surg Am. 1992;74:1450-1455.
    • (1992) J Bone Joint Surg Am , vol.74 , pp. 1450-1455
    • Brumback, R.J.1    Ellison, T.S.2    Molligan, H.3
  • 12
    • 18744389169 scopus 로고    scopus 로고
    • Occupational radiation exposure to the surgeon
    • Occupational radiation exposure to the surgeon. JAAOS. 2005;13:69 -76.
    • (2005) JAAOS , vol.13 , pp. 69-76


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.