메뉴 건너뛰기




Volumn 120, Issue 4, 2006, Pages 261-265

Preliminary results on correlation between neural response imaging and 'most comfortable levels' in cochlear implantation

Author keywords

Cochlear Implants; Electrophysiology; Imaging Techniques

Indexed keywords

ACTION POTENTIAL; ADOLESCENT; ADULT; AGE DISTRIBUTION; CLINICAL ARTICLE; COCHLEA; COCHLEA PROSTHESIS; COCHLEAR NERVE; COMPUTER PROGRAM; CONFERENCE PAPER; CORRELATION ANALYSIS; ELECTRIC POTENTIAL; ELECTRODE; ELECTROPHYSIOLOGY; EVOKED RESPONSE; HEARING LOSS; HUMAN; IMAGING SYSTEM; NERVE POTENTIAL; NEURAL RESPONSE IMAGING; ARTICLE; ARTIFACT; AUDITORY THRESHOLD; ELECTROSTIMULATION; EVOKED BRAIN STEM AUDITORY RESPONSE; FOLLOW UP; HEARING IMPAIRMENT; IMPLANTATION; INTRAOPERATIVE PERIOD; METHODOLOGY; PATHOPHYSIOLOGY; PSYCHOPHYSICS; TREATMENT OUTCOME;

EID: 33747600878     PISSN: 00222151     EISSN: 17485460     Source Type: Journal    
DOI: 10.1017/S0022215106000442     Document Type: Conference Paper
Times cited : (9)

References (7)
  • 1
    • 34249709029 scopus 로고    scopus 로고
    • Relationship between eCAP and HiResolution program settings in patients using the CII Bionic Ear. Poster session
    • Daytona Beach, Florida
    • Overstreet E, Litvak L, Kruger T, Lee J, FaltysM. Relationship between eCAP and HiResolution program settings in patients using the CII Bionic Ear. Poster session, ARO 26th Annual Mid-Winter Meeting, Daytona Beach, Florida, 2003
    • (2003) ARO 26th Annual Mid-Winter Meeting
    • Overstreet, E.1    Litvak, L.2    Kruger, T.3    Lee, J.4    FaltysM5
  • 3
    • 0036282173 scopus 로고    scopus 로고
    • Initial evaluation of the Clarion CII cochlear implant. Speech perception and neural response imaging
    • Frijns JHM, Briaire JJ, de Laat JAPM, Grote JJ. Initial evaluation of the Clarion CII cochlear implant. Speech perception and neural response imaging. Ear Hear 2002;23:184-97
    • (2002) Ear Hear , vol.23 , pp. 184-197
    • Frijns, J.H.M.1    Briaire, J.J.2    de Laat, J.A.P.M.3    Grote, J.J.4
  • 4
    • 0033042930 scopus 로고    scopus 로고
    • Summary of results using the Nucleus CI24M Implant to record the electrically evoked compound action potential
    • Abbas PJ, Brown CJ, Shallop JK, Firszt JB, Hughes ML, Hong SH et al. Summary of results using the Nucleus CI24M Implant to record the electrically evoked compound action potential. Ear Hear 1999;20:45-59
    • (1999) Ear Hear , vol.20 , pp. 45-59
    • Abbas, P.J.1    Brown, C.J.2    Shallop, J.K.3    Firszt, J.B.4    Hughes, M.L.5    Hong, S.H.6
  • 6
    • 0032427791 scopus 로고    scopus 로고
    • The recognition of sentences in noise by normal-hearing listeners using stimulations of cochlear implant signal processors with 6-20 channels
    • Dorman MF, Loizou PF, Fitzke J, Tu Z. The recognition of sentences in noise by normal-hearing listeners using stimulations of cochlear implant signal processors with 6-20 channels. J Acoust Soc Am 1998;104:3583-5
    • (1998) J Acoust Soc Am , vol.104 , pp. 3583-3585
    • Dorman, M.F.1    Loizou, P.F.2    Fitzke, J.3    Tu, Z.4
  • 7
    • 0034902190 scopus 로고    scopus 로고
    • Speech recognition in noise as a function of number of the spectral channel: Comparison of acoustic hearing and cochlear implants
    • Friesen LM, Shannon RV, Baskent D,Wang X. Speech recognition in noise as a function of number of the spectral channel: comparison of acoustic hearing and cochlear implants. J Acoust Soc Am 2001;110:1150-63
    • (2001) J Acoust Soc Am , vol.110 , pp. 1150-1163
    • Friesen, L.M.1    Shannon, R.V.2    Baskent, D.3    Wang, X.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.