메뉴 건너뛰기




Volumn 81, Issue 4, 1998, Pages 151-158

Field restriction and vignetting in contact lenses with opaque peripheries

Author keywords

Opaque contact lenses; Optics; Vignetting; Visual fields

Indexed keywords


EID: 33747584320     PISSN: 08164622     EISSN: 14440938     Source Type: Journal    
DOI: 10.1111/j.1444-0938.1998.tb06773.x     Document Type: Article
Times cited : (14)

References (12)
  • 1
    • 0024577572 scopus 로고
    • A prosthetic contact lens in the treatment of ocular manifestations of albinism
    • Phillips AJ. A prosthetic contact lens in the treatment of ocular manifestations of albinism Clin Exp Optom 1989; 72: 32–34.
    • (1989) Clin Exp Optom , vol.72 , pp. 32-34
    • Phillips, A.J.1
  • 2
    • 0019816743 scopus 로고
    • Simulating decreased visual acuity with a contact lens system
    • Walonker AF, Diddie KR. Simulating decreased visual acuity with a contact lens system. Amer J Ophthalmol 1981; 92: 863–864.
    • (1981) Amer J Ophthalmol , vol.92 , pp. 863-864
    • Walonker, A.F.1    Diddie, K.R.2
  • 3
    • 0024253419 scopus 로고
    • Effect of pupil size on kinetic visual field measurements
    • Gabriel P., Kitchen C., Brown B. Effect of pupil size on kinetic visual field measurements. Clin Exp Optom 1988; 71: 184–187.
    • (1988) Clin Exp Optom , vol.71 , pp. 184-187
    • Gabriel, P.1    Kitchen, C.2    Brown, B.3
  • 5
    • 0024232836 scopus 로고
    • Visual field constriction caused by colored contact lenses
    • Insler MS, Hendriks C., George DM. Visual field constriction caused by colored contact lenses. Arch Ophthalmol 1988; 106: 1680–1682.
    • (1988) Arch Ophthalmol , vol.106 , pp. 1680-1682
    • Insler, M.S.1    Hendriks, C.2    George, D.M.3
  • 6
    • 38249019610 scopus 로고
    • Opaque tinted contact lenses and the visual field
    • Trick LR, Egan DJ. Opaque tinted contact lenses and the visual field. ICLC 1990; 17: 192–195.
    • (1990) ICLC , vol.17 , pp. 192-195
    • Trick, L.R.1    Egan, D.J.2
  • 7
    • 38249019747 scopus 로고
    • Effect of the opaque, colored dot-matrix contact lens on visual field
    • Lee DY, Jurkus JM, Ma S. Effect of the opaque, colored dot-matrix contact lens on visual field. ICLC 1990; 17: 189–191.
    • (1990) ICLC , vol.17 , pp. 189-191
    • Lee, D.Y.1    Jurkus, J.M.2    Ma, S.3
  • 8
    • 84882488842 scopus 로고
    • Does a coloured contact lens change the visual sensitivity of patients
    • Bruce AS, Vingrys AJ. Does a coloured contact lens change the visual sensitivity of patients Clin Exp Optom 1990; 73: 200–204.
    • (1990) Clin Exp Optom , vol.73 , pp. 200-204
    • Bruce, A.S.1    Vingrys, A.J.2
  • 10
    • 0004038248 scopus 로고
    • 10th ed, Oxford, Butterworth-Heinemann
    • Freeman MH. Optics, 10th ed. Oxford: Butterworth-Heinemann, 1990: 262–264.
    • (1990) Optics , pp. 262-264
    • Freeman, M.H.1
  • 11
    • 84989491956 scopus 로고
    • Transmittance characteristics of tinted hydrogel contact lenses intended to change iris colour
    • Dain SJ, Pye DC, Bogaert N., Cooper SJ, Klaunzer PM, Nicolson A. Transmittance characteristics of tinted hydrogel contact lenses intended to change iris colour. Clin Exp Optom 1993; 76: 74–79.
    • (1993) Clin Exp Optom , vol.76 , pp. 74-79
    • Dain, S.J.1    Pye, D.C.2    Bogaert, N.3    Cooper, S.J.4    Klaunzer, P.M.5    Nicolson, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.