메뉴 건너뛰기




Volumn 53, Issue 8, 2006, Pages 1412-1424

A new strategy to enhance cavitational tissue erosion using a high-intensity, initiating sequence

Author keywords

[No Author keywords available]

Indexed keywords

CAVITATIONAL TISSUE; PULSE REPETITION FREQUENCY; TISSUE EROSION;

EID: 33747444281     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2006.1665098     Document Type: Article
Times cited : (45)

References (39)
  • 2
    • 12344327720 scopus 로고    scopus 로고
    • Controlled ultrasound tissue erosion: The role of dynamic interaction between insonation and microbubble activity
    • Z. Xu, J. B. Fowlkes, E. D. Rothman, A. M. Levin, and C. A. Cain, "Controlled ultrasound tissue erosion: The role of dynamic interaction between insonation and microbubble activity," J. Acoust. Soc. Amer., vol. 117, pp. 424-435, 2005.
    • (2005) J. Acoust. Soc. Amer. , vol.117 , pp. 424-435
    • Xu, Z.1    Fowlkes, J.B.2    Rothman, E.D.3    Levin, A.M.4    Cain, C.A.5
  • 3
    • 0017368295 scopus 로고
    • A new non-invasive technique for cardiac pressure measurement resonant scattering of ultrasound from bubble
    • W. M. Fairbank and M. O. Scully, "A new non-invasive technique for cardiac pressure measurement resonant scattering of ultrasound from bubble," IEEE Trans. Biomed. Eng., vol. BME-24, pp. 107-110, 1977.
    • (1977) IEEE Trans. Biomed. Eng. , vol.BME-24 , pp. 107-110
    • Fairbank, W.M.1    Scully, M.O.2
  • 5
    • 0025258575 scopus 로고
    • Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment
    • C. K. Holland and R. E. Apfel, "Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment," J. Acoust. Soc. Amer., vol. 88, pp. 2059-2069, 1990.
    • (1990) J. Acoust. Soc. Amer. , vol.88 , pp. 2059-2069
    • Holland, C.K.1    Apfel, R.E.2
  • 6
    • 0022154262 scopus 로고
    • A precise technique for the measurement of acoustic cavitation thresholds and some preliminary results
    • R. A. Roy, A. A. Atchley, L. A. Crum, J. B. Fowlkes, and J. J. Reidy, "A precise technique for the measurement of acoustic cavitation thresholds and some preliminary results," J. Acoust. Soc. Amer., vol. 78, pp. 1799-1805, 1985.
    • (1985) J. Acoust. Soc. Amer. , vol.78 , pp. 1799-1805
    • Roy, R.A.1    Atchley, A.A.2    Crum, L.A.3    Fowlkes, J.B.4    Reidy, J.J.5
  • 7
    • 0036020091 scopus 로고    scopus 로고
    • The disappearance of ultrasound contrast bubbles: Observations of bubble dissolution and cavitation nucleation
    • W. S. Chen, T. J. Matula, and L. A. Crum, "The disappearance of ultrasound contrast bubbles: Observations of bubble dissolution and cavitation nucleation," Ultrasound Med. Biol, vol. 28, pp. 793-803, 2002.
    • (2002) Ultrasound Med. Biol , vol.28 , pp. 793-803
    • Chen, W.S.1    Matula, T.J.2    Crum, L.A.3
  • 8
    • 0030983613 scopus 로고    scopus 로고
    • Correlation of ultrasound-induced hemolysis with cavitation detector output in vitro
    • E. C. Everbach, I. Makin, M. Azadniv, and R. S. Meltzr, "Correlation of ultrasound-induced hemolysis with cavitation detector output in vitro," Ultrasound Med. Biol., vol. 23, pp. 619-624, 1997.
    • (1997) Ultrasound Med. Biol. , vol.23 , pp. 619-624
    • Everbach, E.C.1    Makin, I.2    Azadniv, M.3    Meltzr, R.S.4
  • 10
    • 1042298886 scopus 로고    scopus 로고
    • Optical monitoring of ultrasound-induced bioeffects in glass catfish
    • S. Maruvada and K. Hynynen, "Optical monitoring of ultrasound-induced bioeffects in glass catfish," Ultrasound Med. Biol, vol. 30, pp. 67-74, 2004.
    • (2004) Ultrasound Med. Biol , vol.30 , pp. 67-74
    • Maruvada, S.1    Hynynen, K.2
  • 11
    • 0032876661 scopus 로고    scopus 로고
    • Erosion of artificial endothelia in vitro by pulsed ultrasound: Acoustic pressure, frequency, membrane orientation and microbubble contrast agent dependence
    • A. A. Brayman, L. M. Lizotte, and M. W. Miller, "Erosion of artificial endothelia in vitro by pulsed ultrasound: Acoustic pressure, frequency, membrane orientation and microbubble contrast agent dependence," Ultrasound Med. Biol, vol. 25, pp. 1305-1320, 1999.
    • (1999) Ultrasound Med. Biol , vol.25 , pp. 1305-1320
    • Brayman, A.A.1    Lizotte, L.M.2    Miller, M.W.3
  • 14
    • 0030459209 scopus 로고    scopus 로고
    • Contrast-agent gas bodies enhance hemolysis induced by lithotripter shock waves and high-intensity focused ultrasound in whole blood
    • D. L. Miller and R. M. Thomas, "Contrast-agent gas bodies enhance hemolysis induced by lithotripter shock waves and high-intensity focused ultrasound in whole blood," Ultrasound Med. Biol, vol. 22, pp. 1089-1095, 1996.
    • (1996) Ultrasound Med. Biol , vol.22 , pp. 1089-1095
    • Miller, D.L.1    Thomas, R.M.2
  • 15
    • 0031747742 scopus 로고    scopus 로고
    • Variables controlling contrast generation in a urinary bladder model
    • E. Y. Hwang, J. B. Fowlkes, and P. L. Carson, "Variables controlling contrast generation in a urinary bladder model," J. Acoust. Soc. Amer., vol. 103, pp. 3706-3716, 1998.
    • (1998) J. Acoust. Soc. Amer. , vol.103 , pp. 3706-3716
    • Hwang, E.Y.1    Fowlkes, J.B.2    Carson, P.L.3
  • 17
    • 0034094045 scopus 로고    scopus 로고
    • The influence of ultrasound frequency and gas-body composition on the contrast agent-mediated enhancement of vascular bioeffects in mouse intestine
    • D. L. Miller and R. A. Gies, "The influence of ultrasound frequency and gas-body composition on the contrast agent-mediated enhancement of vascular bioeffects in mouse intestine," Ultrasound Med. Biol, vol. 26, pp. 307-313, 2000.
    • (2000) Ultrasound Med. Biol , vol.26 , pp. 307-313
    • Miller, D.L.1    Gies, R.A.2
  • 19
    • 0022451343 scopus 로고
    • Chemical reactions by pulsed ultrasound: Memory effects in the formation of NO J and NO J in aerated water
    • A. Henglein and M. Gutierrez, "Chemical reactions by pulsed ultrasound: memory effects in the formation of NO J and NO J in aerated water," Int. J. Radiat. Biol, vol. 50, pp. 527-533, 1986.
    • (1986) Int. J. Radiat. Biol , vol.50 , pp. 527-533
    • Henglein, A.1    Gutierrez, M.2
  • 20
    • 4143144328 scopus 로고    scopus 로고
    • In vivo comparison of multiple pulse and CW strategies for microbubble-enhanced ultrasound therapy
    • B. C. Tran, J. Seo, T. L. Hall, Z. Xu, K. Ives, J. B. Fowlkes, and C. A. Cain, "In vivo comparison of multiple pulse and CW strategies for microbubble-enhanced ultrasound therapy," in Proc. IEEE Ultrason. Symp., 2003, pp. 909-912.
    • (2003) Proc. IEEE Ultrason. Symp. , pp. 909-912
    • Tran, B.C.1    Seo, J.2    Hall, T.L.3    Xu, Z.4    Ives, K.5    Fowlkes, J.B.6    Cain, C.A.7
  • 23
    • 0032169282 scopus 로고    scopus 로고
    • The feasibility of using focused ultrasound for transmyocardial revascularization
    • N. B. Smith and K. Hynynen, "The feasibility of using focused ultrasound for transmyocardial revascularization," Ultrasound Med. Biol, vol. 24, pp. 1045-1054, 1998.
    • (1998) Ultrasound Med. Biol , vol.24 , pp. 1045-1054
    • Smith, N.B.1    Hynynen, K.2
  • 24
    • 0034851297 scopus 로고    scopus 로고
    • Use of a dual-pulse lithotripter to generate a localized and intensified cavitation field
    • D. L. Sokolov, M. R. Bailey, and L. A. Crum, "Use of a dual-pulse lithotripter to generate a localized and intensified cavitation field," J. Acoust. Soc. Amer., vol. 110, pp. 1685-1695, 2001.
    • (2001) J. Acoust. Soc. Amer. , vol.110 , pp. 1685-1695
    • Sokolov, D.L.1    Bailey, M.R.2    Crum, L.A.3
  • 25
    • 0034038913 scopus 로고    scopus 로고
    • Improvement of stone fragmentation during shock wave lithotripsy using a combined EH/PEAA shock wave generator in vitro experiments
    • X. F. Xi and P. Zhong, "Improvement of stone fragmentation during shock wave lithotripsy using a combined EH/PEAA shock wave generator in vitro experiments," Ultrasound Med. Biol, vol. 24, pp. 457-467, 2000.
    • (2000) Ultrasound Med. Biol , vol.24 , pp. 457-467
    • Xi, X.F.1    Zhong, P.2
  • 26
    • 0035212888 scopus 로고    scopus 로고
    • Suppression of large intraluminal bubble expansion in shock wave lithotripsy without compromising stone comminution: Methodology and in vitro experiments
    • P. Zhong and Y. Zhou, "Suppression of large intraluminal bubble expansion in shock wave lithotripsy without compromising stone comminution: Methodology and in vitro experiments," J. Acoust. Soc. Amer., vol. 2001, pp. 3283-3291, 2001.
    • (2001) J. Acoust. Soc. Amer. , vol.2001 , pp. 3283-3291
    • Zhong, P.1    Zhou, Y.2
  • 27
    • 33747445355 scopus 로고    scopus 로고
    • Cloud cavitation control for a therapeutic ultrasound application
    • Boulder, CO
    • T. Ikeda, S. Yoshizawa, M. Tosaki, and Y. Matsumoto, "Cloud cavitation control for a therapeutic ultrasound application," presented at Int. Symp. on Cavitation, Boulder, CO, 2003.
    • (2003) Int. Symp. on Cavitation
    • Ikeda, T.1    Yoshizawa, S.2    Tosaki, M.3    Matsumoto, Y.4
  • 29
    • 28844454163 scopus 로고    scopus 로고
    • The investigation of intensity threshold on ultrasound tissue erosion
    • Z. Xu, J. B. Fowlkes, A. Ludomirsky, and C. A. Cain, "The investigation of intensity threshold on ultrasound tissue erosion," Ultrasound Med. Biol, vol. 31, pp. 1673-1682, 2005.
    • (2005) Ultrasound Med. Biol , vol.31 , pp. 1673-1682
    • Xu, Z.1    Fowlkes, J.B.2    Ludomirsky, A.3    Cain, C.A.4
  • 30
    • 0029904356 scopus 로고    scopus 로고
    • A cost effective degassing system for use in ultrasonic measurements: The multiple pinhole degassing system
    • A. R. Kaiser, C. A. Cain, E. Y. Hwang, J. B. Fowlkes, and R. J. Jeffers, "A cost effective degassing system for use in ultrasonic measurements: The multiple pinhole degassing system," J. Acoust. Soc. Amer., vol. 99, pp. 3857-3860, 1996.
    • (1996) J. Acoust. Soc. Amer. , vol.99 , pp. 3857-3860
    • Kaiser, A.R.1    Cain, C.A.2    Hwang, E.Y.3    Fowlkes, J.B.4    Jeffers, R.J.5
  • 32
    • 0017706950 scopus 로고
    • The effects of ultrasonic activation of gas bodies in Elodea leaves during continuous pulsed irradiation at 1 MHz
    • D. L. Miller, "The effects of ultrasonic activation of gas bodies in Elodea leaves during continuous pulsed irradiation at 1 MHz," Ultrasound Med. Biol, vol. 3, pp. 221-240, 1977.
    • (1977) Ultrasound Med. Biol , vol.3 , pp. 221-240
    • Miller, D.L.1
  • 34
    • 0038076078 scopus 로고    scopus 로고
    • Inertial cavitation dose and hemolysis produced in vitro with or without Optison/sup (R)
    • W.-S. Chen, A. A. Brayman, T. J. Matula, and L. A. Crum, "Inertial cavitation dose and hemolysis produced in vitro with or without Optison/sup (R)/," Ultrasound Med. Biol, vol. 29, pp. 725-737, 2003.
    • (2003) Ultrasound Med. Biol , vol.29 , pp. 725-737
    • Chen, W.-S.1    Brayman, A.A.2    Matula, T.J.3    Crum, L.A.4
  • 35
    • 0034876293 scopus 로고    scopus 로고
    • Lysis and sonoporation of epidermoid and phagocytic monolayer cells by diagnostic ultrasound activation of contrast agent gas bodies
    • D. L. Miller and J. Quddus, "Lysis and sonoporation of epidermoid and phagocytic monolayer cells by diagnostic ultrasound activation of contrast agent gas bodies," Ultrasound Med. Biol, vol. 27, pp. 1107-1113, 2001.
    • (2001) Ultrasound Med. Biol , vol.27 , pp. 1107-1113
    • Miller, D.L.1    Quddus, J.2
  • 36
    • 0038048071 scopus 로고    scopus 로고
    • Tumor growth reduction and DNA transfer by cavitation-enhanced high-intensity focused ultrasound in vivo
    • D. L. Miller and J. Song, "Tumor growth reduction and DNA transfer by cavitation-enhanced high-intensity focused ultrasound in vivo," Ultrasound Med. Biol, vol. 29, pp. 887-893, 2003.
    • (2003) Ultrasound Med. Biol , vol.29 , pp. 887-893
    • Miller, D.L.1    Song, J.2
  • 37
    • 0035729801 scopus 로고    scopus 로고
    • Relationships between scattered signals from ultrasonically activated contrast agents and cell membrane damage in vitro
    • Atlanta, GA, Oct. 7-10
    • A. Amararene, J. B. Fowlkes, J. Song, and D. L. Miller, "Relationships between scattered signals from ultrasonically activated contrast agents and cell membrane damage in vitro," presented at IEEE Ultrason. Symp., An int. symp., Atlanta, GA, Oct. 7-10, 2001.
    • (2001) IEEE Ultrason. Symp., an Int. Symp.
    • Amararene, A.1    Fowlkes, J.B.2    Song, J.3    Miller, D.L.4
  • 38
    • 0031974125 scopus 로고    scopus 로고
    • Effect of acoustic cavitation on platelets in the presence of an echo-contrast agent
    • E. C. Everbach, I. R. S. Makin, C. W. Francis, and R. S. Meltzer, "Effect of acoustic cavitation on platelets in the presence of an echo-contrast agent," Ultrasound Med. Biol, vol. 24, pp. 129-136, 1998.
    • (1998) Ultrasound Med. Biol , vol.24 , pp. 129-136
    • Everbach, E.C.1    Makin, I.R.S.2    Francis, C.W.3    Meltzer, R.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.