메뉴 건너뛰기




Volumn 82, Issue 3, 2006, Pages 1078-1084

Target Vessel Detection and Coronary Anastomosis Assessment by Intraoperative 12-MHz Ultrasound

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANASTOMOSIS; ARTERY CALCIFICATION; ARTERY GRAFT; ARTERY SURGERY; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; CORONARY ARTERY ANASTOMOSIS; FEMALE; GRAFT PATENCY; HUMAN; INTERNAL MAMMARY ARTERY; LEFT ANTERIOR DESCENDING CORONARY ARTERY; LEFT INTERNAL MAMMARY ARTERY; MALE; PEROPERATIVE ECHOGRAPHY; PRIORITY JOURNAL; QUALITY CONTROL; REOPERATION; SCORING SYSTEM; SURGEON;

EID: 33747340195     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2006.03.040     Document Type: Article
Times cited : (6)

References (10)
  • 1
    • 20444429071 scopus 로고    scopus 로고
    • Cardio navigation. planning, simulation, and augmented reality in robotic assisted endoscopic bypass grafting
    • Falk V., Mourgues F., Adhami L., et al. Cardio navigation. planning, simulation, and augmented reality in robotic assisted endoscopic bypass grafting. Ann Thorac Surg 79 (2005) 2040-2048
    • (2005) Ann Thorac Surg , vol.79 , pp. 2040-2048
    • Falk, V.1    Mourgues, F.2    Adhami, L.3
  • 2
    • 0022529293 scopus 로고
    • Intraoperative evaluation of coronary artery bypass graft anastomoses with high-frequency epicardial echocardiography. experimental validation and initial patient studies
    • Hiratzka L.F., McPherson D.D., Lamberth Jr. W.C., et al. Intraoperative evaluation of coronary artery bypass graft anastomoses with high-frequency epicardial echocardiography. experimental validation and initial patient studies. Circulation 73 6 (1986) 1199-1205
    • (1986) Circulation , vol.73 , Issue.6 , pp. 1199-1205
    • Hiratzka, L.F.1    McPherson, D.D.2    Lamberth Jr., W.C.3
  • 3
    • 0032800271 scopus 로고    scopus 로고
    • Intraoperative detection of embedded coronary arteries in MIDCAB using a color Doppler microprobe
    • Oda K., Hirose K., Fukutomi T., Yamashiro T., and Ogoshi S. Intraoperative detection of embedded coronary arteries in MIDCAB using a color Doppler microprobe. Ann Thorac Surg 68 (1999) 263-264
    • (1999) Ann Thorac Surg , vol.68 , pp. 263-264
    • Oda, K.1    Hirose, K.2    Fukutomi, T.3    Yamashiro, T.4    Ogoshi, S.5
  • 4
    • 0036819839 scopus 로고    scopus 로고
    • Epicardial 10-MHz ultrasound in off-pump coronary bypass surgery. a clinical feasibility study using a minitransducer
    • Eikelaar J.H.R., Meijer R., van Boven W.J., et al. Epicardial 10-MHz ultrasound in off-pump coronary bypass surgery. a clinical feasibility study using a minitransducer. J Thorac Cardiovasc Surg 124 (2002) 785-789
    • (2002) J Thorac Cardiovasc Surg , vol.124 , pp. 785-789
    • Eikelaar, J.H.R.1    Meijer, R.2    van Boven, W.J.3
  • 6
    • 0141630431 scopus 로고    scopus 로고
    • Intraoperative assessment of coronary artery bypass grafts
    • Wolf R.K., and Falk V. Intraoperative assessment of coronary artery bypass grafts. J Thorac Cardiovasc Surg 126 (2003) 634-637
    • (2003) J Thorac Cardiovasc Surg , vol.126 , pp. 634-637
    • Wolf, R.K.1    Falk, V.2
  • 7
    • 10744229782 scopus 로고    scopus 로고
    • Novadaq SPY. intraoperative quality assessment in off-pump coronary artery bypass grafting
    • Reuthebuch O., Haussler A., Genoni M., et al. Novadaq SPY. intraoperative quality assessment in off-pump coronary artery bypass grafting. Chest 125 2 (2004) 418-424
    • (2004) Chest , vol.125 , Issue.2 , pp. 418-424
    • Reuthebuch, O.1    Haussler, A.2    Genoni, M.3
  • 8
    • 0141629559 scopus 로고    scopus 로고
    • Multi-detector row CT versus coronary angiography. preoperative evaluation before totally endoscopic coronary artery bypass grafting
    • Herzog C., Dogan S., Diebold T., et al. Multi-detector row CT versus coronary angiography. preoperative evaluation before totally endoscopic coronary artery bypass grafting. Radiology 229 1 (2003) 200-208
    • (2003) Radiology , vol.229 , Issue.1 , pp. 200-208
    • Herzog, C.1    Dogan, S.2    Diebold, T.3
  • 9
    • 0034571444 scopus 로고    scopus 로고
    • Endoscopic Doppler for detecting vessels in closed chest bypass grafting
    • Falk V., Fann I.J., Gruenenfelder J., and Burdon T.A. Endoscopic Doppler for detecting vessels in closed chest bypass grafting. Heart Surg Forum 3 4 (2000) 331-333
    • (2000) Heart Surg Forum , vol.3 , Issue.4 , pp. 331-333
    • Falk, V.1    Fann, I.J.2    Gruenenfelder, J.3    Burdon, T.A.4
  • 10
    • 1942500935 scopus 로고    scopus 로고
    • Endoscopic localization and assessment of coronary arteries by 13mhz epicardial ultrasound
    • Budde R.P.J., Meijer R., Bakker P.F.A., Borst C., and Gruendeman P.F. Endoscopic localization and assessment of coronary arteries by 13mhz epicardial ultrasound. Ann Thorac Surg 77 (2004) 1586-1592
    • (2004) Ann Thorac Surg , vol.77 , pp. 1586-1592
    • Budde, R.P.J.1    Meijer, R.2    Bakker, P.F.A.3    Borst, C.4    Gruendeman, P.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.