메뉴 건너뛰기




Volumn 26, Issue 6, 2006, Pages 697-699

Easy and effective way to remove residual silicone oil droplets in phakic patients

Author keywords

Floaters; Intraocular oil droplets; Proliferative vitreoretinopathy; Retinal detachment; Silicone oil; Vitreoretinal surgery

Indexed keywords

SILICONE OIL;

EID: 33747339272     PISSN: 0275004X     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.iae.0000223682.67314.b9     Document Type: Article
Times cited : (1)

References (5)
  • 1
    • 0012980704 scopus 로고    scopus 로고
    • Silicone oil in vitreoretinal surgery
    • Ryan SJ, ed. St. Louis: Mosby
    • Gallemore RP, McCuen BW. Silicone oil in vitreoretinal surgery. In: Ryan SJ, ed. Retina. St. Louis: Mosby; 2001:2195-2220.
    • (2001) Retina , pp. 2195-2220
    • Gallemore, R.P.1    McCuen, B.W.2
  • 2
    • 0023949344 scopus 로고
    • Complications associated with the use of silicone oil in 150 eyes after retina-vitreous surgery
    • Federman JL, Schubert HD. Complications associated with the use of silicone oil in 150 eyes after retina-vitreous surgery. Ophthalmology 1988;95:870-876.
    • (1988) Ophthalmology , vol.95 , pp. 870-876
    • Federman, J.L.1    Schubert, H.D.2
  • 3
    • 0036796119 scopus 로고    scopus 로고
    • Comparison of silicone oil removal with passive drainage alone versus passive drainage combined with air-fluid exchange
    • Dabil H, Akduman L, Olk J, Cakir B. Comparison of silicone oil removal with passive drainage alone versus passive drainage combined with air-fluid exchange. Retina 2002;22:597-601.
    • (2002) Retina , vol.22 , pp. 597-601
    • Dabil, H.1    Akduman, L.2    Olk, J.3    Cakir, B.4
  • 4
    • 0029858961 scopus 로고    scopus 로고
    • Irreversible silicone oil adhesion to silicone intraocular lenses. A clinicopathologic analysis
    • Apple DJ, Federman JL, Krolicki TJ, et al. Irreversible silicone oil adhesion to silicone intraocular lenses. A clinicopathologic analysis. Ophthalmology 1996;103:1555-1561.
    • (1996) Ophthalmology , vol.103 , pp. 1555-1561
    • Apple, D.J.1    Federman, J.L.2    Krolicki, T.J.3
  • 5
    • 0033980867 scopus 로고    scopus 로고
    • Silicone oil removal from a silicone intraocular lens with perfluorohexyloctane
    • Damiana Z, Schrage N, Kirchhof B, Wenzel M. Silicone oil removal from a silicone intraocular lens with perfluorohexyloctane. J Cataract Refract Surg 2000;26:301-302.
    • (2000) J Cataract Refract Surg , vol.26 , pp. 301-302
    • Damiana, Z.1    Schrage, N.2    Kirchhof, B.3    Wenzel, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.